MA61_MA63-en-GB_V1.0 3/15
13
NCVNonContactACVoltageDetector
CAUTION:RemovetestleadsfrommeterbeforeattemptingNCVtests.Alwaysverifythe
NCVfunctiononaknownlivecircuitbeforeperformingtests.DonotusetheNCVfunctionifthe
displaydoes not show EF whenthefunction switch isturnedto the NCV position.If the meter
doesnotswitchonwhentheNCVmodeisinitiated,pleasecheckthebatteries.
WiththemeteronandswitchedtotheNCVmode,holdingthefronttipoftheclampjawneara
liveelectrical,electromagnetic,orelectrostatic field causes thebeeperto sound,thedisplayto
shows dashes, and the red LED lamp to flash. The threshold is 100V. The greater the field
strengththegreaterthenumberofdashesandthefastertherateoftheaudiblebeepsandthe
flashingLEDlamp.
Ifthemeterdoesnotemitatoneordisplaydashesinthismode,thereisstillthepossibilitythat
voltageispresent.Pleaseusecaution.
1. Turn the
Function switch to the NCV position to access the NonContact Voltage Detect
mode.
2. NotethevoltagedetectiondisplayiconNCVandthelargerEFdisplay.Ifthesedisplaysare
not seen when the NCV mode is accessed do NOT attempt to use the meter. Check the
batteries and try
again. If the meter still does not
switch on when the NCV mode is accessed please
havethemeterservicedorreplaced.
3. Place the meter near a source of electrical energy.
The front tip of the clamp offers the highest
sensitivity.
4. Notetheaudiblebeeping,thedashdisplays,
andthe
flashing LEDlamp when an electrical or
electromagneticfieldofatleast100Vissensed.Note
that electrostatic energy will trigger the NCV
detector,thisisnormal.
Fig10NONCONTACTACVOLTAGEDETECTOR
DataHold
TofreezethedisplayedreadingontheLCD,presstheDataHold(H)button(theHiconwill
appearonthedisplay).ToreleasetheDataHoldfunctionandreturnthemetertonormal
operation,presstheDataHold(H)buttonagain(theHiconwillswitchoff).