EXTECH MA620 [15/17] Specifications
![EXTECH MA620 [15/17] Specifications](/views2/1666810/page15/bgf.png)
MA61_MA63-en-GB_V1.0 3/15
15
Specifications
GeneralSpecifications
Display 6000countLCDwithmultifunctionindicators
Fullscale6200countsforCapacitancefunction
Fullscale9999countsforFrequencyfunction
LEDlamp ForNon‐ContactVoltageDetector
Functions Current(ACA,DCA),Voltage(VAC,VDC),Resistance,
Capacitance,Frequency,Non‐ContactVoltagedetector,
Continuity,andDiodetest
Polarity “‐“indicatesnegativepolarity(positivepolarityassumed)
Currentsensor Halleffect
Overloadindication O.L
DCAzeroadjust MA63:One‐touchZERObutton(alsousedasaRelative
function);MA61:RELbutton(Relative)
Displayrate 2~3readings/second
Battery Two1.5VAAAbatteries
Operatingtemperature 0
0
Cto40
0
C(32
0
Fto104
0
F)
OperatingHumidity <75%RH0~30C(32
0
Fto86
0
F)
<50%RH30~40C(86
0
Fto104
0
F)
Storagetemperature‐10
0
Cto50
0
C(14
0
Fto122
0
F)
Altitude 2000m(6562’)
Powerconsumption 20mADCapprox.
Weight 170g(6.0oz.)includingbattery
Dimensions 175x60x33.5mm(6.9x2.4x1.3”)(HxWxD)
Jawopening 17mm(0.7”)3000MCM
Standards IEC/EN61010‐1,EN61010‐2‐033,EN61010‐2‐032;CategoryIII
300V,CategoryII600V;pollutionclass2
Electromagnetic
compatibility
<1V/mRFfield:Overallaccuracy= specifiedaccuracy+5%of
therange.Unspecifiedindicationfor1V/mRFfield.
TestLeads UseonlytestprobesratedCATII600V,CATIII300Vorbetter
thatmeettherequirementsofIEC61010‐031
Содержание
- True rms mini clamp meters 1
- Features 2
- Introduction 2
- International safety symbols 3
- Safety 3
- Safety notices 3
- 2 3 4 5 6 4
- Control buttons description 4
- Fig 1 meter parts 4
- Meter description 4
- Fig 2 function switch 5
- Function switch description 5
- Model ma61 5
- Model ma61 model ma63 5
- Model ma63 5
- Display icon descriptions 6
- Measurement unit prefixes 6
- Ω kω mω 6
- Automatic power off apo 7
- Current measurements clamping technique 7
- Fig 3 correct and incorrect clamping techniques 7
- Meter power 7
- Operation 7
- Ac current measurements 8
- Dc current measurements ma63 only 8
- Fig 4 correct and incorrect zero techniques 8
- Ac voltage measurements 9
- Fig 5 ac voltage measurement 9
- Frequency measurements 9
- Voltage measurements 9
- Dc voltage measurements 10
- Fig 6 dc voltage measurement 10
- Fig 7 resistance measurement 10
- Resistance measurements 10
- Capacitance measurements 11
- Continuity measurements 11
- Fig 8 capacitance measurement 11
- Diode test 12
- Fig 9 diode test 12
- Data hold 13
- Fig 10 non contact ac voltage detector 13
- Ncv non contact ac voltage detector 13
- Battery replacement 14
- Cleaning 14
- Zero relative measurements 14
- General specifications 15
- Specifications 15
- Range specifications 16
- Copyright 2015 flir systems inc 17
- Www extech com 17
Похожие устройства
- EXTECH PQ3210 Инструкция по эксплуатации
- EXTECH PQ3210 Инструкция EN
- EXTECH PQ3220 Инструкция по эксплуатации
- EXTECH PQ3220 Инструкция EN
- Fluke FLK-I17XX-FLEX3K-4 Инструкция по эксплуатации
- Fluke FLK-I17XX-FLEX3K-4 Инструкция EN
- Fluke FLK-323 Инструкция по эксплуатации
- Fluke FLK-323 Инструкция EN
- Fluke FLK-323 Документация
- Fluke FLK-323 Расширенная инструкция
- Fluke FLK-324 Инструкция по эксплуатации
- Fluke FLK-324 Инструкция EN
- Fluke FLK-324 Документация
- Fluke FLK-324 Расширенная инструкция
- Fluke FLK-325 Инструкция по эксплуатации
- Fluke FLK-325 Инструкция EN
- Fluke FLK-325 Документация
- Fluke FLK-325 Расширенная инструкция
- Fluke FLK-373 Инструкция по эксплуатации
- Fluke FLK-373 Инструкция EN