EXTECH EX655 [18/35] Μa ac dc current measurements using test leads

EXTECH EX655 [18/35] Μa ac dc current measurements using test leads
EX65xenGB_V1.67/16
18
µAAC/DCCurrentMeasurementsusingTestLeads
WARNING:Donothandlethetestleadsabovethefinger/handguardbarrier.
CAUTION:ObserveCATII1000VandCATIII600VwithrespecttoEarthGround.
1. InserttheblacktestleadintotheCOMterminalandtheredtestleadintotheAterminal.
2. Turnthemeter’sfunctionswitchtothe position.TheµAunitsymbolwillappearonthe
displayindicatingthatmicroamperesarebeingmeasured.
3. ThemeterdisplaywillshowACorDC(usetheMbuttontoselectACorDC).
4. Currentmeasurementsmustbetakeninserieswiththecircuitundertest.Seeaccompanying
diagram.
5. Touchtheblacktestleadtothenegativesideofthecircuitandtheredtestleadtothe
positivesideofthecircuit.
6. Readthecurrentmeasurementinthedisplayrepresentedbythenumericaldigitsandthebar
graph(EX655).Thedisplaywillindicatetheproperdecimal
pointandvalue.InDC,Ifthe
polarityisreversed,thedisplaywillshow()minusbeforethevalue.
AC DC
Fig44µAAC/DCCURRENTMEASUREMENTS