EXTECH MG320 [12/12] Copyright 2015 flir systems inc
![EXTECH MG320 [12/12] Copyright 2015 flir systems inc](/views2/1668828/page12/bgc.png)
12 MG310-en-GB_V1.0 12/15
Note:Accuracyisstatedat73.4
o
F(23
o
C)and40~75%RH.
Note:Accuracyspecificationsconsistoftwoelements:
(%reading)–Thisistheaccuracyofthemeasurementcircuit.
(+digits)–Thisistheaccuracyoftheanalogtodigitalconverter.
Display BacklitLCD(max.reading1999)
Lowbatteryindication Batteryicon
appearswhenbatteriesneedtobereplaced.
Overloadindication Insulationresistancetesting>5.5Gdisplayedwhenthemeterrangehas
beenexceeded.
Rangeselection Automatic
Unitsofmeasureformat Functionsandunitsofmeasureareshownsimultaneously.
Testingcontrols ForInsulationResistancetesting:ManualstartandAutomaticstop.
Testbutton Red
lamponTESTbuttonindicatesthattestisinprogress.
Self‐Test 10MΩ(±1%)
ContinuityCheck Audiblesignalwhenresistanceis<20(approx.).
Battery Six(6)1.5V‘AA’batteries
CurrentConsumption 200mAapprox.withmaximumoutput(10mAundernormalconditions).
OperatingTemperature 0ºCto40ºC(32ºFto104ºF)
Storage
Temperature‐20
o
Cto60
o
C(‐4
o
Fto140
o
F)
OperatingHumidity <85%RH
StorageHumidity <90%RH
OperatingAltitude 2000m(7000ft.)maximum
Weight 0.7kg.(1.5lbs.)
Size 150x100x71mm(6.0x4.0x2.8in.)
Safety Thismeterisintendedfororiginofinstallationuseandprotected by
doubleinsulationperEN61010‐1
andIEC61010‐12
nd
Edition(2001)to
CategoryIII600V;PollutionDegree2.
Copyright©2015FLIRSystems,Inc.
Allrightsreservedincludingtherightofreproductioninwholeorinpartinanyform
www.extech.com
Содержание
- Insulation resistance tester 1
- Model mg310 1
- With continuity and ac voltage modes 1
- Danger 2
- Introduction 2
- Safety 2
- Caution 3
- Electrical safety symbols 3
- Warning 3
- Control buttons 4
- Meter description 4
- 2 3 4 5 6 7 5
- Display backlight 5
- Display description 5
- Low battery indication 5
- Operating instructions 5
- Insulation resistance measurements 6
- Dielectric absorption ratio dar testing 7
- Polarization index pi testing 7
- Accuracy self test function 8
- Low resistance continuity testing 8
- Ac voltage measurements 9
- Battery installation 10
- Maintenance 10
- Specifications 11
- Copyright 2015 flir systems inc 12
- Www extech com 12
Похожие устройства
- EXTECH MG320 Инструкция язык en
- EXTECH MG325 Инструкция по эксплуатации
- EXTECH MG325 Инструкция язык en
- EXTECH MG325 Расширенная инструкция
- EXTECH MG500 Инструкция по эксплуатации
- EXTECH MG500 Data Sheet
- EXTECH MG500 Инструкция язык en
- Fluke FLK-1503 Инструкция по эксплуатации
- Fluke FLK-1503 Инструкция язык en
- Fluke FLK-1503 Data Sheet
- Fluke FLK-1503 Расширенная инструкция
- Fluke FLK-1507 Инструкция по эксплуатации
- Fluke FLK-1507 Data Sheet
- Fluke FLK-1507 Инструкция язык en
- Fluke FLK-1507 Расширенная инструкция
- Fluke FLK-1550C Инструкция по эксплуатации
- Fluke FLK-1550C Инструкция язык en
- Fluke FLK-1550C Data Sheet
- Fluke FLK-1550C Расширенная инструкция
- Fluke FLK-1550C-KIT Инструкция по эксплуатации