Daikin EWAT310B-SRA2 [21/62] Ewat b sr

Daikin EWAT290B-SRA1 [21/62] Ewat b sr
21/62
TECHNICAL SPECIFICATION
EWAT~B-SR
MODEL
EWAT205B
-SRA2
EWAT215B
-SRA1
EWAT240B
-SRA2
EWAT260B
-SRA2
EWAT290B
-SRA1
EWAT310B
-SRA2
COOLING
PERFORMANCE
Capacity - Cooling
kW
200
203
230
248
266
290
Capacity control - Type
Step
Step
Step
Step
Step
Step
Capacity control - Minimum
capacity
%
19
50
17
25
24
14
Unit power input - Cooling
kW
84.7
91.4
89.1
100
115
119
EER
2.36
2.22
2.59
2.47
2.30
2.43
ESEER (+opt FANMOD
(5)
)
3.97
3.73
3.98
4.09
4.12
4.05
IPLV (+opt FANMOD
(5)
)
4.72
4.36
4.88
4.38
4.84
4.83
SEER (+opt FANMOD
(5)
)
(1)
3.92
3.82
4.29
4.01
4.26
4.20
DIMENSIONS
Height
mm
1822
1822
2540
2540
2540
2540
Width
mm
1204
1204
2236
2236
2236
2236
Length
mm
4170
3780
2326
2326
2326
3226
WEIGHT
Unit Weight
kg
1177
1191
1815
1843
1935
2251
Operating Weight
kg
1190
1210
1822
1849
1951
2268
WATER HEAT
EXCHANGER
Type
(2)
PHE
PHE
PHE
PHE
PHE
PHE
Water Volume
l
11
16
11
11
16
19
Water flow rate
l/s
9.6
9.7
11.0
11.9
12.7
13.9
Water pressure drop
(4)
kPa
49.9
36.8
64.5
73.5
59.9
42.1
Insulation material
Closed cell
Closed cell
Closed cell
Closed cell
Closed cell
Closed cell
AIR HEAT EXCHANGER
Type
(2)
Mch
Mch
Mch
Mch
Mch
Mch
FAN
Type
(2)
DPT
DPT
DPT
DPT
DPT
DPT
Drive
(2)
Phase cut
Phase cut
VFD fans
VFD fans
VFD fans
VFD fans
Diameter
mm
450
450
800
800
800
800
Nominal air flow
l/s
14202
12325
17064
17064
17064
21330
Quantity
No.
10
10
4
4
4
5
Speed
rpm
1200
1200
780
780
780
780
Motor input
kW
3.6
3.6
4.7
4.7
4.7
5.9
COMPRESSOR
Type
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
Oil charge
l
15.3
12.6
16.5
17.7
17.0
19.1
Quantity
No.
4
2
4
4
3
4
SOUND LEVEL
(3)
Sound Power - Cooling
dB(A)
85
88
85
85
86
86
Sound Pressure level@1m
distance Cooling
dB(A)
66.6
69.4
66.0
66.2
66.7
66.8
REFRIGERANT CIRCUIT
Refrigerant type
R32
R32
R32
R32
R32
R32
Refrigerant charge
kg
18
17
36
38
36
42
N. of circuits
No.
2
1
2
2
1
2
PIPING CONNECTIONS
Evaporator water
inlet/outlet
mm
88.9
76.1
88.9
88.9
76.1
88.9
All the performances (Cooling capacity, unit power input in cooling and EER) are based on the following conditions: evaporator 12.0/7.0°C; ambient 35.0°C,
unit at full load operation; operating fluid: Water; fouling factor = 0.
(1) In accordance with standard EN14825:2013, comfort low temperature, average climate. SEER and µs values applicable Ecodesign regulation: (EU) No
2016/2281.
(2) PHE: Plate Heat Exchanger; S&T: Single Pass Shell & Tube; MCH: Microchannel; DPT: Direct Propeller Type; DOL: Direct On Line - VFD: Inverter
(3) Sound power level (referred to evaporator 12/7°C, ambient 35°C full load operation) are measured in accordance with ISO 9614 and Eurovent 8/1 for
Eurovent certified units. The certification refers only to the overall sound power level, the sound pressure is calculated from the sound power level and are
for information only and not considered binding. The minimum capacity indicated is referred to unit operating at standard Eurovent conditions. Dimensions
and weights are for indication only and not considered binding. Before designing the installation, consult the official drawings available from the factory at
request. All the data are referred to standard unit without options. All data are subject to change without notice.
(4) The value refers to the pressure drops in the evaporator only.
(5) Option FANMOD consist in Continuous Fan Speed Regulation and improves part load operation. Single-V units are standardly equipped with continuous
fan control. Multi-V units require opt 99