MUST PH20-3000TL [2/3] Solar system

MUST PH20-3000TL [2/3] Solar system
Solar System
Single Phase Inverter
-03- -04-
PH2000 DTL Series
Single Phase Inverter
Feature:
Specification
Zero export to grid
Reactive Power Control (RPC)
U-disk for software updating
Light weight in small size
Without LCD,no risk of dust or water
Seperate APP setting/monitoring
Wi-Fi/GPRS
Lantrun Pad local monitoring
Input Data (DC)
Max. DC power
Max. DC voltage
Start voltage
DC nominal voltage
PV voltage range
MPP voltage range
Max. input current per string of tracker A/tracker B
Number of independent MPP inputs
Output Data (AC)
Nominal AC output power
Max. AC apparent power
Max. output current
AC nominal voltage; range
AC grid frequency; range
Power factor at rate power
Power factor
THDi
AC connection
Euro - eta
Protection Devices
DC reverse polarity protection
DC switch ratiing for each MPPT
Output over current protection
Output overvoltage Protection-varistor
Ground fault monitoring
Grid monitoring
Integrated all - pole sensitive leakage current
monitoring unit
General Data
Dimensions (W / H / D)
Weight
Operating temperature range
Noise emission (typical)
Altitude
Relative humidity
Consumption: operating (standby) / night
Topology
Cooling concept
Environmental protection rating
Features
DC connection
AC connection
Display
Interfaces: Wi-Fi/USB/GPRS/RS485
Warranty: 5 years / 10 years/15 years
97.00%
96.50%
99.50%
97.10%
96.50%
99.50%
97.10%
96.50%
99.50%
97.10%
96.50%
99.50%
600V
100V
360V
100V-600V
120V-550V
11A/11A
2
4000W
3600W
3600VA
16.4A
4600W
4200W
4200VA
19.1A
5400W
5000W
5000VA
22.8A
5000W
4600W
4600VA
21.0A
-25...+60°C (-13...+ 140°F) with derating above 45 °C11F
≤ 25 dB(A)
Up to 2000m (6560ft) without power derating
95%
<5W / < 0.5 W
Transformerless
Natural
IP65
H4/MC4
Screw terminal
LED
Yes/Yes/Opt/Opt
Yes /Opt/Opt
CE,IEC 62109, VDE 0126-1-1, VDE-AR-N4105,RD1663,G59,G83, AS4777, AS/NZS 3100, CGC
220V/230V/240V; 180V-280V
50,60H;±5 Hz
1
0.9leading…0.9lagging
<3%
Single phase
Yes
Yes
Yes
Yes
Yes
Yes
380/300/150mm
11kg 12kg 13kg 13kg
PH20-3600DTL PH20-4200DTL PH20-4600DTL PH20-5000DTL
Model
Yes
Specifications
Efficiency
Max. efficiency
MPPT efficiency
Certificates and approvals
The unit is bidirectional which apply to PV system withbattery to store energy. Energy produced by the PV system is used to
optimize self-consumption; excess energy is used to charge the batteries, and then fed into the public grid when the PV energy
is adequate, When PV energy output is in sufficient to support connected loads, the system automatically get energy from the
batteries if battery capacity is abundant. If the battery capacity is insufficient to meet own consumption requirements, electricity
will be drawn from the public grid.
Introduction:
LCD Display Information
1. The inverter power flow direction indicator
2. The inverter operation status indicator
3. PV input terminals
4. Battery input terminals and cover
5. PV input switch
6. WIFI com module and USB port
7. BAT._NTC and RS485 communication (BMS com, load monitor com, )
8. AC Output terminals and cover
9. Inverter Serial No.
10. Spec label
11. Warning signals label
1
2
3 4 5 6 7 8
9
10
11
Solar System Connection
External
Battery pack
PV panel
Home Appliances
Utility
Back Panel
Скачать