Daikin UAT180CGXY1 [3/8] This ensures that air conditioners in the same building resume
![Daikin UAT300CGXY1 [3/8] This ensures that air conditioners in the same building resume](/views2/1694807/page3/bg3.png)
Compact and light
The at top design of the unit allows for maximum utilization of warehouse and container space, while the light frame ensure ease of
handling and installation.
Flexibility of Air Supply **
A belt driven fan is used such that the air volume and static pressure required can be adjusted according to the requirements. This exibility
allows for wider application and oers the possibility to reach the best working conditions considering the unit’s characteristics.
** The pulley (eld supply) is changeable at site for exibility in terms of static pressure and air ow.
Large line up
Line-up overview - Capacity (Btu/hr)
Operation Range Outdoor Unit 60.000 80.000 100.000 115.000 150.000 200.000 250.000 300.000 330.000 400.000
C/O
Standard
eciency
UAT-AY1
High eciency UAT-CGXY
Easy to control
User-friendly wired remote controller is oered as standard:
› SLM controller, for UAT-AY1 180/240/280/320, includes 15 hour delay timer, temperature setting…
›
Sequential LCD controller, for UAT-CGXY and UAT-AY1 C10/C12, incorporates many functions like a 7 programmable timer,
temperature setting, compressor running,error status, energy saving mode and key lock function.
› For applications requiring mechanical control, the high eciency range oers an an optional series: UAT-CGX9***.
*** For more details, please contact your local dealer
Wide operation range
The units operate from 54°CDB (UAT-AY1 from 52°CDB) down to 20°CDB in cooling mode.
54°CDB20°CDB
Indoor air quality
› The standard washable lter can easily be accessed for facilitated maintenance.
›
An additional eld supplied lter can easily be installed on the 2 inch rail to meet the indoor air quality requirements of the application.
Auto random restart with
last state memory
In case of sudden power failure, random restart with previous
settings to prevent power surges after blackout.
Auto Restart System
Power Failure
E
2
PROM
Power Returns
Setting stored before
power failure
Operation
Stop Restart
›
In case of sudden power failure during operation, unit will
be automatically restarted in 180s – 224s dierent recovery
timing patterns
›
The operation is based on the previous setting: Mode,
Temperature and Fan Speed.
›
This ensures that air conditioners in the same building resume
control randomly instead of turning on at the same time,
preventing power surge after a blackout.
Содержание
- Air conditioners 1
- Cooling only 1
- Uat cgxy remote control 1
- Features 2
- High efficiency 2
- Once the ductwork is installed the only thing left to do is 2
- Plug and play installation 2
- Auto random restart with last state memory 3
- Cdb 20 cdb 3
- Compact and light 3
- Control randomly instead of turning on at the same time 3
- Easy to control 3
- Flexibility of air supply 3
- In case of sudden power failure during operation unit will 3
- Indoor air quality 3
- Large line up 3
- Sequential lcd controller for uat cgxy and uat ay1 c10 c12 incorporates many functions like a 7 programmable timer 3
- The operation is based on the previous setting mode 3
- This ensures that air conditioners in the same building resume 3
- Wide operation range 3
- High efficiency range 4
- High performance under standard and high ambient conditions uat300cgy 4
- Independent refrigerant circuits 4
- Start up booster mode for quick cooling 4
- Uat cgxy 4
- And condenser fan motor and has a 24 volt transformer provided for field installed thermostat 5
- Anti corrosion protection as standard 5
- By opening the top service panel without stopping the unit operation 5
- Comp 1 dry contact input y1 cooling 1 5
- Comp 2 dry contact input y2 cooling 2 5
- Cooling only 5
- Easy duct design 5
- Environment 5
- Evaporator fan dry contact input g fan 5
- Flexible control optional mechanical control series 5
- For certain applications a mechanical control is required instead of pcb control for the uat cgy series this is available through an optional 5
- Horizontal air discharge from the top and return air from the bottom for an easy duct design 5
- Quiet operation as standard 5
- Rooftop unit thermostat 5
- Separate service panel 5
- Series the rooftop with mechanical control provides connection to the thermostat for control of evaporator fan motor compressors 5
- Service panels are divided into two different sections for ease of servicing preliminary servicing troubleshooting can be conducted 5
- Standard anticorrosion protection with the hydrophilic gold fin coating giving the condenser coil a longer life span under corrosive 5
- The operating sound level is down to 66 dba 5
- Vac 24 vac 5
- Standard efficiency range 6
- Uat ay1 6
- Available on uat320ay1 7
- Capacity is required 7
- Cooling only 7
- Field convertible return and supply air increases flexibility of installation 7
- High efficiency 7
- Horizontal throw 2 down throw 7
- Mode by simply repositioning the fan group 7
- Nominal eer up to 3 08 w w 10 5 btu hr w 7
- Partial loading 7
- Quiet operation as standard 7
- The 2 compressors systems can run at part load when less 7
- The operating sound level is down to 63 dba 7
- The return and discharge air flow can be shifted to vertical 7
- Daikin products are distributed by 8
- Ecpen13 135 8
- Naamloze vennootschap zandvoordestraat 300 b 8400 oostende belgium www daikin eu be 0412 120 336 rpr oostende 8
- Remote control uat cgxy 8
Похожие устройства
- Daikin UAT180CGXY1 Руководство по эксплуатации
- Daikin UAT180CGXY1 Инструкция по монтажу
- Daikin UAT240CGXY1 Брошюра
- Daikin UAT240CGXY1 Руководство по эксплуатации
- Daikin UAT240CGXY1 Инструкция по монтажу
- Daikin UAT300CGXY1 Брошюра
- Daikin UAT300CGXY1 Руководство по эксплуатации
- Daikin UAT300CGXY1 Инструкция по монтажу
- Daikin UAT150CGXY19 Брошюра
- Daikin UAT150CGXY19 Руководство по эксплуатации
- Daikin UAT150CGXY19 Инструкция по монтажу
- Daikin UAT180CGXY19 Брошюра
- Daikin UAT180CGXY19 Руководство по эксплуатации
- Daikin UAT180CGXY19 Инструкция по монтажу
- Daikin UAT240CGXY19 Брошюра
- Daikin UAT240CGXY19 Руководство по эксплуатации
- Daikin UAT240CGXY19 Инструкция по монтажу
- Daikin UAT300CGXY19 Брошюра
- Daikin UAT300CGXY19 Руководство по эксплуатации
- Daikin UAT300CGXY19 Инструкция по монтажу