Daikin FXFQ63PVE [51/90] Ceiling mounted duct type

Daikin FXFQ100PVE [51/90] Ceiling mounted duct type
Specifications ED39-865
50 FXMQ-P (R-410A)
Ceiling Mounted Duct Type
Note:
1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5 m, level difference : 0 m.
2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5 m, level difference : 0 m.
3 Indoor temp. : 20°CDB / outdoor temp. : 7°CDB, 6°CWB / Equivalent piping length : 7.5 m, level difference : 0 m.
4 External static pressure is changeable in 13 or 14 stages within the ( ) range by remote controller.
5 Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its colorimetric method (gravity method)
50% or more.
6 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
7 Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are
normally somewhat higher as a result of ambient conditions.
8 Refer to page 57 for Fan Motor Input.
Model FXMQ100PVE FXMQ125PVE
1 Cooling Capacity (19.5°CWB)
kcal/h 10,000 12,500
Btu/h 39,600 49,500
kW 11.6 14.5
2 Cooling Capacity (19.0°CWB) kW 11.2 14.0
3 Heating Capacity
kcal/h 10,800 13,800
Btu/h 42,700 54,600
kW 12.5 16.0
Casing Galvanized Steel Plate Galvanized Steel Plate
Dimensions: (H×W×D) mm 300×1,400×700 300×1,400×700
Coil (Cross
Fin Coil)
Rows×Stages×Fin Pitch mm 3×16×1.75 3×16×1.75
Face Area 0.383 0.383
Fan
Model
Type Sirocco Fan Sirocco Fan
Motor Output × Number
of Units
W 350×1 350×1
Air Flow Rate (HH/H/L)
m³/min 32/27/23 39/33/28
cfm 1,130/953/812 1,377/1,165/988
External Static
Pressure
Pa Standard 100 (200-50
4) Standard 100 (200-50
4)
Drive Direct Drive Direct Drive
Temperature Control Microprocessor Thermostat for Cooling and Heating Microprocessor Thermostat for Cooling and Heating
Air Filter
5
5
Piping
Connections
Liquid Pipes mm
φ
9.5 (Flare Connection)
φ
9.5 (Flare Connection)
Gas Pipes mm
φ
15.9 (Flare Connection)
φ
15.9 (Flare Connection)
Drain Pipe mm
VP25
External Dia. 32
Internal Dia. 25
VP25
External Dia. 32
Internal Dia. 25
Mass (Weight) kg 46 46
7 Sound Level (HH/H/L) dBA
220V 43/41/39 44/42/40
240V 43/41/39 44/42/40
Safety Devices
Fuse.
Fan Driver Overload Protector.
Fuse.
Fan Driver Overload Protector.
Refrigerant Control Electronic Expansion Valve Electronic Expansion Valve
Connectable Outdoor Unit R-410A P Series R-410A P Series
Standard Accessories
Operation Manual. Installation Manual. Drain Hose. Clamp
Metal. Insulation for Fitting. Sealing Pads. Clamps.
Washers. Screws. Air Discharge Flange. Air Suction
Flange.
Operation Manual. Installation Manual. Drain Hose. Clamp
Metal. Insulation for Fitting. Sealing Pads. Clamps.
Washers. Screws. Air Discharge Flange. Air Suction
Flange.
Drawing No. C : 3D060388
() ()
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3