Daikin FXFQ63PVE [81/90] Fxmq p r 410a

Daikin FXFQ25PVE [81/90] Fxmq p r 410a
Installation Manual ED39-865
80 FXMQ-P (R-410A)
3PN06583-7K
English 11
(5) Mount the provided wire fixing bracket (12) with the wire fix-
ing screw (13). Fix each wire with the provided clamp (8).
[Precautions for Power Supply Wiring]
Connect round crimp-style terminals provided with insulation
sleeves to the terminal block for power supply.
Be sure to follow the instructions provided below if the spec-
ified terminals cannot be used.
Otherwise, abnormal heat may be generated as a result
of the loosening of the wires.
If stranded wires are used, do not solder the front end of the
wires.
Connect proper wires securely and fix the wires so that exter-
nal force will not be imposed on the terminals.
Use an appropriate screwdriver to tighten the terminal
screws. The screw heads may be damaged if the screwdriver
is too small and the terminal screws will not be tightened
properly.
Do not tighten the terminal screws excessively, or otherwise
the screw heads may be damaged.
Refer to the table below for the required tightening torque val-
ues of the terminal screws.
10-2 WIRING EXAMPLE
WARNING
Install an earth leakage breaker.
The installation of an earth leakage breaker is imperative for the
prevention of electric shocks and fire accidents.
No. 1 system: When using 1 remote controller for 1 indoor
unit
No. 2 system: For group control or use with 2 remote con-
trollers
Tightening torque (N·m)
Terminal block for remote controller
and transmission wires
0.80 - 0.96
Terminal block for power supply 1.18 - 1.44
Power supply wiring
Earth wiring
Transmission wiring
Remote controller wiring
Fixing use
Wire fixing screw (13) (accessory)
Wire fixing bracket (12) (accessory)
Clamp (8) (accessory)
Electric wire
Round crimp-style terminal
Attach insulation sleeve
Connect the wires
evenly.
Do not connect a
wire to the single
side only.
Do not connect
wires different
from each other in
diameter.
Indoor unit A Indoor unit B
Most
downstream
Indoor unit
Power supply
single phase
50Hz 220-240V
or
single phase
60Hz 220V
Power supply
single phase
50Hz 220-240V
or
single phase
60Hz 220V
Power supply
single phase
50Hz 220-240V
or
single phase
60Hz 220V
Outdoor unit
FT
1
L
1
1
1
PP
2
P
N
1
2
P
T
F
2
F
P
F
1
2
2
2
P
1
N
2
P
2
F
IN/D
1
OUT/D
1
P
F
2
F
1
P
L
F
1 2
T
2
T
1
PP
21
F
2
N
F
L
12
TT
P
Remote controller Remote controller Remote controller
LN LN LN
(option) (option) (option)
Outdoor unit
Note) There is not need to set the indoor unit
address when using group control.
(It is automatically set when the power
is turned on.)
Indoor
unit A
Indoor unit B
Most down-
stream
indoor unit
For use with 2
remote controllers
Case of group control
LN
Remote controller
Remote controller
(option)
Remote controller
1
P
2
P
1
P
2
P
1
P
2
P
1
PP
21
F
2
N
F
L
NL
12
FF
12
FF
12
TT
1
PP
21
F
2
F
12
TT
NL
1
PP
21
F
2
F
12
TT
IN/D
OUT/D
(option)
Power supply
single phase
50Hz 220-240V
or
single phase
60Hz 220V

Содержание

Скачать