Daikin RXYQ38MY1B [9/42] Technology
![Daikin FXZQ32MVE [9/42] Technology](/views2/1700118/page9/bg9.png)
• Introduction
1
5
• Systems • Introduction
8
5 technology
DC fan motor
The use of a DC fan motor offers substantial improvements in operating efficiency compared to conventional AC motors, especially during low speed
rotation.
Aero fitting grill & aero spiral fan
These new features achieve a low noise fan with a large airflow, and realize a compact casing together with the compressor linking technology.
e-Bridge circuit
Prevents accumulation of liquid refrigerant in the condenser. This results in more efficient use of the condenser surface under any circumstance and
leads in turn to better energy efficiency.
An increase in evaporative capacity systems from the newly developed refrigeration circuit, known as the SCe-bridge circuit, which adds super cooling
prior to the expansion cycle. By adopting this circuit, the COPs in both cooling and heating have been drastically improved.
First in the
industry
DC motor
DC motor efficiency
(comparison with a conventional AC motor)
AC motor
Efficiency (%)
100
80
60
40
20
0
200 300 400 500 600 700 800 900 1000
Motor speed (rpm)
DC fan motor structure
magnet
N
E
W
Aero spiral fan
Bending the fan blade
edge reduces turbulence,
resulting in less pressure
loss.
Aero fitting grille
New shape promotes a
spiral discharge airflow,
resulting in reduced
pressure loss.
First in the
industry
Evaporative capacity can be
raised by taking super cooling
just before the electronic
expansion valve
By the SCe- bridge circuit,
cooling and heating attain the
improvement in COP
Evaporative-capacity has been improved by adopting the SCe-Bridge Circuit.
SCe-Bridge Circuit
Current
Evaporative-capacity
Содержание
- I introduction table of contents 2
- Introduction 3
- Possible indoor units using r 410a 3
- Systems introduction 3
- 1 indoor unit capacity index 4
- Possible outdoor units using r 410a 4
- 1 indoor units 5
- Nomenclature 5
- 2 outdoor units 6
- Nomenclature 6
- Introduction 7
- Line up 7
- Systems introduction 7
- Technology 8
- Aero fitting grill aero spiral fan 9
- Dc fan motor 9
- E bridge circuit 9
- Technology 9
- Compact aero box 10
- E pass heat exchanger 10
- I demand function 10
- Technology 10
- 1 creating maximum comfort 11
- Main features 11
- 1 creating maximum comfort 12
- Main features 12
- 1 creating maximum comfort 13
- Main features 13
- 2 energy efficient solution 14
- Main features 14
- 2 energy efficient solution 15
- Main features 15
- 2 energy efficient solution 16
- Main features 16
- 3 high reliability 17
- Main features 17
- 3 high reliability 18
- Main features 18
- 4 eco friendly 19
- Main features 19
- 5 easy and flexible design 20
- Main features 20
- 5 easy and flexible design 21
- Main features 21
- 5 easy and flexible design 22
- Main features 22
- 6 simple and rapid installation 23
- Main features 23
- 6 simple and rapid installation 24
- Main features 24
- Main features 25
- Standard vrv system 25
- System 25
- 6 simple and rapid installation 26
- Main features 26
- 1 selection procedure system based on cooling load 27
- Selection procedure 27
- 1 selection procedure system based on cooling load 28
- Selection procedure 28
- 1 selection procedure system based on cooling load 29
- Selection procedure 29
- 2 capacity correction ratio 30
- Selection procedure 30
- 2 capacity correction ratio 31
- Selection procedure 31
- 2 capacity correction ratio 32
- Selection procedure 32
- 2 capacity correction ratio 33
- Selection procedure 33
- 2 capacity correction ratio 34
- Selection procedure 34
- 2 capacity correction ratio 35
- Selection procedure 35
- 2 capacity correction ratio 36
- Selection procedure 36
- 2 capacity correction ratio 37
- Selection procedure 37
- 3 refnet pipe system 38
- Selection procedure 38
- 3 refnet pipe system 39
- Selection procedure 39
- 4 refnet pipe selection 40
- Selection procedure 40
- Eede03 2 3 05 2003 prepared in belgium by vanmelle 42
- Specifications are subject to change without prior notice 42
- Systems 42
- Zandvoordestraat 300 b 8400 ostend belgium internet http www daikineurope com 42
Похожие устройства
- Daikin RXYQ38MY1B Сервис мануал
- Daikin RXYQ38MY1B Инструкция по монтажу
- Daikin RXYQ40MY1B Технические данные
- Daikin RXYQ40MY1B Сервис мануал
- Daikin RXYQ40MY1B Инструкция по монтажу
- Daikin RXYQ42MY1B Технические данные
- Daikin RXYQ42MY1B Сервис мануал
- Daikin RXYQ42MY1B Инструкция по монтажу
- Daikin RXYQ44MY1B Технические данные
- Daikin RXYQ44MY1B Сервис мануал
- Daikin RXYQ44MY1B Инструкция по монтажу
- Daikin RXYQ46MY1B Технические данные
- Daikin RXYQ46MY1B Сервис мануал
- Daikin RXYQ46MY1B Инструкция по монтажу
- Daikin RXYQ48MY1B Технические данные
- Daikin RXYQ48MY1B Сервис мануал
- Daikin RXYQ48MY1B Инструкция по монтажу
- Daikin RXYQ5M7W1B Инструкция по эксплуатации
- Daikin RXYQ5M7W1B Технические данные
- Daikin RXYQ5M7W1B Сервис мануал