TRACO POWER TIB 080-148EX [3/6] Tib 080 ex series 80 watt

TRACO POWER TIB 080-148EX [3/6] Tib 080 ex series 80 watt
Safety Standards
- IT / Multimedia Equipment
IEC 60950-1
EN 60950-1
UL 60950-1
CSA-C22.2, 60950-1-07
- Industrial Control Equipment
UL 508
- ATEX
EN 60079-0
EN 60079-7
EN 60079-15
EX II3G Ex nA nC IIC T4 GC
- HazLoc
UL 121201
Class I; Div 2; Groups A,B,C,D; T4
- Certification Documents
www.tracopower.com/overview/tib080-ex
Protection Class
Class I Prepared: Connection to PE
Pollution Degree
PD 2: Office or Laboratory Environments
Over Voltage Category
OVC II
Safety Specifications
EMC Emissions
EN 61000-6-3 (Generic Residential)
EN 61204-3 (Low Voltage Power Supplies)
EN 50121-3-2 (EMC for Rolling Stock)
EN 50121-4 (Railway Application Signalling)
- Conducted Emissions
EN 55011 class B (internal filter)
EN 55032 class B (internal filter)
- Radiated Emissions
EN 55011 class B (internal filter)
EN 55032 class B (internal filter)
- Harmonic Current Emissions
EN 61000-3-2, class A
EMC Immunity
EN 50121-3-2 (EMC for Rolling Stock)
EN 50121-4 (Railway Application Signalling)
EN 61000-6-2 (Generic Industrial)
EN 61204-3 (Low Voltage Power Supplies)
- Electrostatic Discharge
Air:
EN 61000-4-2, ±8 kV, perf. criteria A
Contact:
EN 61000-4-2, ±4 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 10 V/m, perf. criteria A
- EFT (Burst)
EN 61000-4-4, ±2 kV, perf. criteria B
- Surge
L to L:
EN 61000-4-5, ±1 kV, perf. criteria B
L to PE:
EN 61000-4-5, ±2 kV, perf. criteria B
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
- PF Magnetic Field
EN 61000-4-8, 30 A/m, perf. criteria A
- Voltage Dips & Interruptions
230 VAC / 50 Hz:
EN 61000-4-11
30%, 25 periods, perf. criteria C
60%, 10 periods, perf. criteria C
>95%, 1 period, perf. criteria B
>95%, 5 periods, perf. criteria C
20%, 250 periods, perf. criteria C
115 VAC / 60 Hz:
EN 61000-4-11
30%, 25 periods, perf. criteria C
60%, 10 periods, perf. criteria C
>95%, 1 period, perf. criteria B
>95%, 5 periods, perf. criteria C
20%, 250 periods, perf. criteria C
- Voltage Sag Immunity
SEMI F47, criteria A
EMC Specifications
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–40°C to +70°C
General Specifications
TIB 080-EX Series, 80 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.