Planet FT-804 [7/18] Link fall pass through lfp

Planet FT-802 [7/18] Link fall pass through lfp
2
3
Side View (FT-80X)
One DIP switch for Link Fault Pass Through (LFP) feature, “ON”
to turn-on the LLCF and LLR detection. And “OFF” to turn–off this
feature. Please refer to the following sections for more.
DIP Switch for LFP function.
Chapter 5
Link Fault Pass through (LFP)
The LFP function includes the Link Fault Pass Through function
(LLCF/LLR) and the DIP Switch design. LLCF/LLR can immediately
alarm administrators the problem of the link media and provide
efcient solution to monitor the net. The DIP Switch provides
disable or enable the LFP function.
LLCF (Link Loss Carry Forward) means when a device connected
to the converter and the TP line loss the link, the converter’s ber
will disconnect the link of transmit. LLR (Link Loss Return) means
when a device connected to the converter and the ber line loss
the link, the converter’s ber will disconnect the link of transmit.
Both can immediately alarm administrators the problem of the link
media and provide efcient solution to monitor the net.