Daikin RXYQ16PAY6 [11/33] Design drawing

Daikin RXYQ50PAY6 [11/33] Design drawing
Fig-1 Design Drawing, Piping Drawing Indoor Unit and Outside Unit Location Fig-2 Cooling Water Diagram
OFFICE
18 19
SUZLON Energy Ltd.
4
ROOF LEVEL
SECOND FLOOR
FIRST FLOOR
GROUND FLOOR
BASEMENT
THIRD FLOOR
BLOCK CLC BLOCK E
PAC-1PAC-2
PAC-1
BLOCK CLC
Ø100
Ø65
KEY PLAN
CT LOCATION BLOCK D&E
CL-I
CL-II
CL-IV
CL-III
PHE-1
PP3
CT LOCATION BLOCK D&E
PHE-2
PP2PP1
SP3SP2SP1
Ø300
Ø350
Ø200
Ø200
MESH SIZE-50
EQUALISER & MAKE-UP PIPING TO BE
SHOWN AS PER COOLING TOWER
MANUFACTURER'S STANDARD
HEAD = 32 MWC
FLOW = 136.8 CMH EACH ( 2W+1S)
HEAD = 25 MWC
FLOW = 283.50 CMH EACH
FLOW = 141.75 CMH PER CELL
T IN = 32.7° C
T OUT = 28.7° C
RECIRCULATION WATER :
T IN = 34.0° C
T OUT = 30.0° C
FLOW = 283.5 CMH EACH
COOLING TOWER WATER :
T IN = 28.7° C
T OUT = 32.7° C
FLOW = 283.5 CMH EACH
D
(R. O. QUALITY)
Ø40
Ø25
Ø40
MAKE UP WATER TANK
Ø40
Ø25
1000 LITRES
EXPANSION TANK
Ø150
ODU-1
ODU-1
ODU-1 ODU-2
ODU-1 ODU-2 ODU-3 ODU-4 ODU-5
ODU-1 ODU-2 ODU-3 ODU-4 ODU-5 ODU-6 ODU-7 ODU-8
ODU-1 ODU-2 ODU-3 ODU-4
Ø250
Ø200
Ø150
Ø125
Ø150
Ø200
Ø250
ODU
TYPICAL ODU CONNECTION
Ø50
SOCKET FOR FLOW SWITCH
Ø200
Ø200
Ø200
Ø150
Ø350
Ø350
Ø350
Ø150
Ø100
Ø100 Ø100
Ø80
Ø80Ø100
Ø80
Ø80 Ø125
Ø200
Ø250
Ø250
ODU-5
ODU-8
ODU-8
ODU-1
ODU-1
AIR PURGE
CHILLED WATER RETURN LINE
CHILLED WATER SUPPLY LINE
BUTTERFLY VALVE
BALL VALVE (FULL BORE)
NON RETURN VALVE
BALANCING VALVE
2-WAY MODULATING TYPE SOLENOID VALVE
THERMOMETER POCKET
PRESSURE GAUGE WITH SIPHON & COCK ASS.
Y STRAINER
GLOBE VALVE
PIPE SIZE (mm NB)
Ø
L E G E N D
M
DRAIN (IN CIVIL SCOPE)
MAKE UP CONNECTION (IN CIVIL SCOPE)
2-WAY SOLENOID VALVE ON/OFF TYPE
WITH 3 SPEED FAN CONTROL
D
PURGE VALVE
BUTTERFLY VALVE (MOTORISED ON/OFF TYPE)
M
CHILLED WATER RETURN LINE
CHILLED WATER SUPPLY LINE
LOUVERS
M
M
MM
M
MM M
M M M
M
MM
M
M
TOTAL ODU 38 NO'S
TOTAL FLOW 4560 LPM, 273.6 CMH
AUTO PURGE VALVES
TO SUIT PIPING LAYOUT
WHERE REQUIRED
PE-1 PE-2
FD
PD
PD
PD
FD
P
W
HV
M
UP
TERRACE
TERRACE
TERRACE
LADIES TOILET
GENTS TOILET
COURTYARD
BELOW
450x750 DUCT
UPTO A/C ROOM
(CORE CUT REQD.)
AIR COOLED M/C
REF.PIPING
FROM
900x300
F.A.DUCT
WITH DAMPER
AIRTIGHT INSULATED BOXING
450x150 GRILL
WITH DAMPER
450x150 GRILL
WITH DAMPER
600x200
GRILL
WITH DAMPER
ST5 ST5
150X150
GRILL WITH DAMPER
AIRTIGHT ROOM
FOR A/C UNIT
WITH ACCESS &
FLOOR DRAIN 40NB
600x100 GRILL
600x100 GRILL
600x100 SIDE THROW GRILL
VERTICAL PIPING UPTO MEZ.
FOR FRESH AIR
LOUVERS /GRILL
TO BE PROVIDED
ON EACH DOOR
AREA 1 SQFT.(EACH)
33T
G
G
G
C
HH
H
C
C
E
E
G
G
G
G
G
E
G
C
H
H
C
H
H
G
G
G
G
C
C
C
E
E
D
F
G
C
G
H
H
H
H
D
D
G
72T
72T
72T
33T
20HP
C
E
E
73T
20HP
20HP
UNITS
20HP
UNITS
2 1
AIRTIGHT INSULATED BOXING
HI WALL UNIT
WITH DRAIN PUMP
HI WALL UNIT
WITH DRAIN PUMP
HI WALL UNIT
WITH DRAIN PUMP
8TR
1380x1110
x470 H
8TR
1380x1110
x470 H
DRAIN THROUGH
FLOORING
DRAIN PIPING
THROUGH
WALL CHASING
(BELOW
AV WINDOW)
Ø500
Ø450
Ø350
Ø300
Ø250
3TR
450x200
450x125
900x200
2 TR
1.5 TR
3TR
3TR
3TR
2.5TR
2.5TR
800x600
600x600
600x500
450x500
PIPES UPTO
A/C ROOM
800x200
GROUND FLOOR
450x200
450x125
700x600
450x200
450x125
450x200
450x125
450x200
450x125
450x200
450x125
450x200
450x125
450x200
450x125
450x300
450x250
450x200
800x600
600x500
450x500
700x600
450x125
450x200
450x125
450x200
450x125
450x200
450x200
450x125
450x200
450x125
450x300
600x600
800x600
600x600
600x500
450x500
450x200
450x125
450x200
450x125
450x200
450x125
450x200
450x125
450x200
450x125
700x600
450x200
450x125
450x200
450x125
450x200
450x125
450x200
450x125
450x200
450x125
450x300
Ø450
Ø400
Ø350
Ø300
Ø250
Ø450
Ø400 Ø350
Ø300
Ø250
16TR
A/C UNIT
450x200
450x250
450x250
450x250
450x250
450x250
450x200 450x200
450x200
450x200
450x200
450x150
450x150
450x150
450x150
450x150
450x150
COLLAR
600x100
COLLAR
600x100
COLLAR
600x100
1.5 TR
800x200
1.5 TR
800x200
INSULATED BOXING
WITH AIRTIGHT PARTITIONS
BETWEEN IDUs
Ø400
Ø500
Ø500
3TR
3TR
16TR
PACKAGED
A/C UNIT
450x200
450x125
450x200
450x125
300x150
3TR
Ø450
Ø400
Ø350
Ø300
Ø250
UP PIECEUP PIECE
450x200
450x125
450x200
450x125
450x200
450x125
450x200
450x125
450x125
LENGTH OF
PIECES CHANGED
Ø550
Ø500
Ø450
Ø400
Ø350
Ø300
Ø550
Ø500
Ø350 Ø350
Ø300
Ø600
Ø450
Ø600
CORE CUT Ø200x2NOS FOR COND. PIPING
P1-T
P1
P1
P1
P1-T
P1-T
P1A
P1
P1-T
P1B-T
P2A
P1-T
P1-T P2A P1-T P2A
P2A
P1A-T
P1
P1
P2A
P1-T P1-T
P2A
P2A
P1-T
P1-T
P1-T
P1-T
P2A
P2A
P1-T
P2A
P1-T
P1-T
P1-T
P2A
P1A-T
P2A
P1B-T
P1-T
P1-T
P1-T
30HP
73T
73T
B
B
33T
73T
72T
72T
30HP
UNITS UNITS UNITS
1 2 3
B
73T
22T
22T
22T
73T
FOR FRESH AIR-400Wx150H
OPENING IN WALL
72T
72T
20HP
22T
22T
22T
UNITS
2
UNITS
1
C
20HP
72T
C
72T
20HP
UNIT
2
UNIT
1
C
20HP
UNIT
2
UNIT
1
-250
-250
3252
5636
1380x1110
x470 H
1380x1110
x470 H
1380x1110
x470 H
1380x1110
x470 H
8TR 6TR
8TR 8TR
Q
1
2
3
4
5
6
P N M L K J
H G F E D C
900x400
900x400
900x
400
900x
400
900
x400
750
x400
400
x400
2.1TR
DRAIN PIPING
THROUGH FLOORING
2.1TR
400x150 GRILL
WITH DAMPER
ABOVE F.C.
150x150
GRILL WITH
DAMPER
150x150
GRILL WITH
DAMPER
1.33TR
0.83TR
0.83TR
250x100
150x150
200x150
DESIGN DRAWING
PE-1 PE-2
FIRST FLOOR
REF.PIPING
DRAIN TO BE
CONNECTED MAIN
DRAIN HEADER
1.33TR
2.67TR
P2A
P1-T
P1-T
G
H
G
22T