Daikin RXYQ120PTJU [4/20] Contents
![Daikin RXYQ120PTJU [4/20] Contents](/views2/1717999/page4/bg4.png)
RXYQ72PYDN
RXYQ96PYDN
RXYQ120PYDN
RXYQ144PYDN
RXYQ168PYDN
RXYQ192PYDN
RXYQ216PYDN
RXYQ240PYDN
REYQ72PYDN
REYQ96PYDN
REYQ120PYDN
REYQ144PYDN
REYQ168PYDN
REYQ192PYDN
REYQ216PYDN
REYQ240PYDN
RXYQ72PTJU
RXYQ96PTJU
RXYQ120PTJU
RXYQ144PTJU
RXYQ168PTJU
RXYQ192PTJU
RXYQ216PTJU
RXYQ240PTJU
REYQ72PTJU
REYQ96PTJU
REYQ120PTJU
REYQ144PTJU
REYQ168PTJU
REYQ192PTJU
REYQ216PTJU
REYQ240PTJU
VRVIII System
air conditioner
Operation
manual
1 English
CONTENTS
1. SAFETY CONSIDERATIONS......................... 1
2. SPECIFICATIONS .......................................... 4
3. WHAT TO DO BEFORE OPERATION............ 5
4. REMOTE CONTROLLER AND COOL/HEAT
SELECTOR : NAME AND FUNCTION OF
EACH SWITCH AND DISPLAY ...................... 5
5. OPERATION RANGE ..................................... 7
6. OPERATION PROCEDURE ........................... 7
7. OPTIMUM OPERATION ............................... 11
8. SEASONAL MAINTENANCE ....................... 12
9. FOLLOWING SYMPTOMS ARE NOT AIR
CONDITIONER TROUBLES ........................ 12
10. TROUBLE SHOOTING................................. 14
1. SAFETY CONSIDERATIONS
Please read these “SAFETY CONSIDERATIONS”
carefully before installing the air conditioning unit
and be sure to install it correctly. After completing
the installation, make sure that the unit operates
properly during the test operation.
Please instruct the customer on how to operate the
unit and keep it maintained.
Also, inform the customer that this operation manual
should be stored along with the installation manual
for future reference.
This air conditioner comes under the term “appli-
ances not accessible to the general public”.
Meaning of danger, warning, caution and note symbols.
DANGER ......... Indicates an imminently haz-
ardous situation which, if not
avoided, will result in death or
serious injury.
WARNING ....... Indicates a potentially hazard-
ous situation which, if not
avoided, could result in death
or serious injury.
CAUTION
......... Indicates a potentially hazardous
situation which, if not avoided,
may result in minor or moderate
injury. It may also be sued to alert
against unsafe practices.
NOTE .............. Indicates a situation that may
result in the unit or property-
damage-only accidents.
Keep these warning sheets handy so that you
can refer to them if needed.
Also, if this unit is transferred to a new user, make sure
to hand over this operation manual to the new user.
DANGER
• Refrigerant gas may produce a toxic gas if it
comes in contact with fire such as from a fan,
heater, stove or cooking device. Exposure to
this gas could cause severe injury or death.
• For refrigerant leakage, consult your dealer.
Refrigerant gas is heavier than air and replaces oxy-
gen. A massive leak could lead to oxygen depletion,
especially in basements, and an asphyxiation haz-
ard could occur leading to serious injury or death.
• Any abnormalities in the operation of the air
conditioner such as smoke or fire could result
in severe injury or death.
Turn off the power and contact your dealer imme-
diately for instructions.
• Do not install the unit in an area where flam-
mable materials are present due to risk of
explosion resulting in serious injury or death.
• If equipment utilizing a burner is used in the
same room as the air conditioner, there is the
danger of oxygen deficiency which could lead
to an asphyxiation hazard resulting in serious
injury or death.
Be sure to ventilate the room sufficiently to avoid
this hazard.
• Safely dispose of the packing materials.
Packing materials, such as nails and other metal or
wooden parts, may cause stabs or other injuries.
Tear apart and throw away plastic packaging bags
so that children will not play with them. Children
playing with plastic bags face the danger of death
by suffocation.
WARNING
• Be sure to install a ground fault circuit breaker.
Failure to install a ground fault circuit interrupter
may result in electric shocks or fire.
• It is not good for your health to expose your
body to the air flow for a long time.
01_EN_3P215731-1D.fm Page 1 Tuesday, February 5, 2008 6:35 PM
Содержание
- Operation manual 1
- System air conditioner 1
- 1 13 2 3
- _cv_3p215731 1d fm page 3 wednesday february 6 2008 11 34 am 3
- Contents 4
- Safety considerations 4
- Electrical work 6
- Pay attention to operating sound 6
- Place of installation 6
- Design pressure 7
- Dimensions h w d 7
- Drainage through drainpipe 7
- English 4 7
- Make sure that the drainpipe is installed prop erly to drain water if no water is discharged from the drainpipe while the air conditioner is cooling operation the drain pipe may be clogged with dust or dirt and water leakage from the indoor units may result stop operating the air conditioner and consult your dealer 7
- Model name 7
- Nominal cooling capacit 7
- Nominal heating capacit 7
- Power supply 7
- Refrigerant 7
- Specifications 7
- English 8
- If your installation has a customized control system ask your daikin dealer for the operation that corre sponds to your system outside units refer to figure 1 8
- Names and functions of parts refer to figure 1 1 outside unit 2 indoor unit 3 remote controller 4 inlet air 5 outlet air 6 bs unit 7 cool heat selector 8 refrigerant piping figure 1 shows system with cool heat selector 8
- On off button press the button and the system will start press the button again and the system will stop 8
- Operation lamp red the lamp lights up during operation 8
- Remote controller and cool heat selector name and function of each switch and display 8
- Remote controller and cool heat selector name and function of each switch and display refer to figure 2 and 3 8
- This operation manual is for the following system with standard control before initiating operation contact your daikin dealer for the operation that cor responds to your system type and mark 8
- What to do before operation 8
- 1 cooling heating automatic and fan only operation 10
- Operation procedure 10
- Operation range 10
- 2 program dry operation 11
- 3 adjusting the air flow direc tion refer to figure 6 only for dou ble flow multi flow corner ceiling suspended and wall mounted 12
- 4 programming start and stop of the system with timer refer to figure 9 13
- 5 setting the master remote con troller 13
- 6 precautions for group con trol system or two remote controller control system 14
- Optimum operation 14
- 1 at the beginning of the season 15
- 1 the system does not operate 15
- 2 at the end of the season 15
- 2 it stops sometimes 15
- 3 cool heat cannot be changed over 15
- Following symptoms are not air conditioner troubles 15
- Seasonal maintenance 15
- 10 the units can give off odours 16
- 11 the outside unit fan does not rotate 16
- 5 the fan strength does not cor respond to the setting 16
- 6 the fan direction does not cor respond to the setting 16
- 7 white mist comes out of the unit 16
- 8 noise of air conditioners 16
- 9 dust comes out of the unit 16
- Cooling and heating do not work 16
- Fan operation is possible but 16
- 12 the display shows 17
- 13 the compressor or fan in the outside unit does not stop 17
- 14 the inside of outside unit is warm even when the unit has stopped 17
- 15 hot air is emitted even though the unit is stopped 17
- 16 does not cool very well 17
- Trouble shooting 17
- After sales service and warranty 18
- P215731 1d em07a037a 20
Похожие устройства
- Daikin RXYQ120PYDN Спецификация
- Daikin RXYQ120PYDN Руководство по вводу в эксплуатацию
- Daikin RXYQ120PYDN Инструкция по эксплуатации
- Daikin RXYQ120PYDN Сервис мануал
- Daikin RXYQ120PTJU Сервис мануал
- Daikin RXYQ72PATJ Спецификация
- Daikin RXYQ72PATJ Руководство по вводу в эксплуатацию
- Daikin RXYQ96PATJ Спецификация
- Daikin RXYQ96PATJ Руководство по вводу в эксплуатацию
- Daikin RXYQ108PATJ Спецификация
- Daikin RXYQ108PATJ Руководство по вводу в эксплуатацию
- Sinbo SBG 7102A User guide
- Daikin RXYQ72PATJ Инструкция по монтажу
- Daikin RXYQ72PATJ Инструкция по эксплуатации
- Daikin RXYQ96PATJ Инструкция по монтажу
- Daikin RXYQ96PATJ Инструкция по эксплуатации
- Daikin RXYQ108PATJ Инструкция по монтажу
- Daikin RXYQ108PATJ Инструкция по эксплуатации
- Daikin RXYQ72PAYD Спецификация
- Daikin RXYQ72PAYD Руководство по вводу в эксплуатацию