Daikin RXYQ120PTJU [6/20] Electrical work
![Daikin RXYQ120PTJU [6/20] Electrical work](/views2/1717999/page6/bg6.png)
3 English
• Do not turn off the power immediately after
stopping operation.
Always wait at least five minutes before turning off
the power. Otherwise, water leakage and trouble
may occur.
• The appliance is not intended for use by young
children or infirm persons without supervision.
• The remote controller should be installed in
such away that children cannot play with it.
• Consult with installation contractor for clean-
ing the inside of the air conditioner.
Wrong cleaning may make the plastics parts broken
or cause failure of water leakage or electric shock.
• Do not touch the air inlet or aluminum fin of
the air conditioner.
Otherwise, injury may be caused.
• Do not place objects in direct proximity of the
outside unit and do not let leaves and other
debris accumulate around the unit.
Leaves are a hotbed for small animals which can
enter the unit. Once in the unit, such animals can
cause malfunctions, smoke or fire when making
contact with electrical parts.
NOTE
• Never press the button of the remote control-
ler with a hard, pointed object.
The remote controller may be damaged.
• Never pull or twist the electric wire of the
remote controller.
It may cause the unit to malfunction.
• Do not place appliances which produce open
fire in places exposed to the air flow from the
unit or under the indoor unit. It may cause
incomplete combustion or deformation of the
unit due to the heat.
• Arrange the drain hose to ensure smooth
drainage. Incomplete drainage may cause
wetting of the building, furniture etc.
• Do not place the controller exposed to direct
sunlight.
The LCD display may get discolored, failing to dis-
play the data.
• Do not wipe the controller operation panel
with benzine, thinner, chemical dustcloth, etc.
The panel may get discolored or the coating peeled
off. If it is heavily dirty, soak a cloth in water-diluted
neutral detergent, squeeze it well and wipe the
panel clean. And wipe it with another dry cloth.
• Dismantling of the unit, treatment of the refrig-
erant, oil and eventual other parts, should be
done in accordance with the relevant local and
national regulations.
[Place of Installation]
• Make sure that the air conditioner is located in
a sufficiently ventilated place not surrounded
by obstacles.
• Do not use the air conditioner in the following
places.
a.
Places with a mist of mineral oil, such as cutting oil.
b. Locations such as coastal areas where there is
a lot of salt in the air.
c. Locations such as hot springs resorts where
there is a lot of sulfur in the air.
d. Locations such as factories where the power
voltage varies a lot.
e. In cars, boats, and other vehicles.
f. Locations such as kitchens where oil may splat-
ter or there is steam in the air.
g. Locations where equipment that produces elec-
tromagnetic waves is found.
h. Places with an acid or alkaline mist.
i. Places where fallen leaves are accumulated or
weeds grow close together.
• Take snow protection measures.
Contact your dealer for the details of snow protec-
tion measures, such as the use of a snow protec-
tion hood.
[Electrical Work]
•
Do not attempt to conduct electrical work or
grounding work unless you are licensed to do so.
Consult with your dealer for electrical work and
grounding work.
• Use a dedicated circuit for the air conditioner.
[Pay Attention to Operating Sound]
• Be sure to use the following places.
a. Places that can sufficiently withstand the weight
of the air conditioner and suppress the operat-
ing sound and vibration of the air conditioner.
b. Places where warm air from the air outlet of the
outside unit or the operating sound of the out-
side unit does not annoy neighbors.
• Make sure that there are no obstacles close to
the outside unit.
Obstacles close to the outside unit may drop the
performance of the outside unit or an increase in
the operating sound of the outside unit.
• Consult your dealer if the air conditioner in
operation generates unusual noise.
01_EN_3P215731-1D.fm Page 3 Tuesday, February 5, 2008 6:35 PM
Содержание
- Operation manual 1
- System air conditioner 1
- 1 13 2 3
- _cv_3p215731 1d fm page 3 wednesday february 6 2008 11 34 am 3
- Contents 4
- Safety considerations 4
- Electrical work 6
- Pay attention to operating sound 6
- Place of installation 6
- Design pressure 7
- Dimensions h w d 7
- Drainage through drainpipe 7
- English 4 7
- Make sure that the drainpipe is installed prop erly to drain water if no water is discharged from the drainpipe while the air conditioner is cooling operation the drain pipe may be clogged with dust or dirt and water leakage from the indoor units may result stop operating the air conditioner and consult your dealer 7
- Model name 7
- Nominal cooling capacit 7
- Nominal heating capacit 7
- Power supply 7
- Refrigerant 7
- Specifications 7
- English 8
- If your installation has a customized control system ask your daikin dealer for the operation that corre sponds to your system outside units refer to figure 1 8
- Names and functions of parts refer to figure 1 1 outside unit 2 indoor unit 3 remote controller 4 inlet air 5 outlet air 6 bs unit 7 cool heat selector 8 refrigerant piping figure 1 shows system with cool heat selector 8
- On off button press the button and the system will start press the button again and the system will stop 8
- Operation lamp red the lamp lights up during operation 8
- Remote controller and cool heat selector name and function of each switch and display 8
- Remote controller and cool heat selector name and function of each switch and display refer to figure 2 and 3 8
- This operation manual is for the following system with standard control before initiating operation contact your daikin dealer for the operation that cor responds to your system type and mark 8
- What to do before operation 8
- 1 cooling heating automatic and fan only operation 10
- Operation procedure 10
- Operation range 10
- 2 program dry operation 11
- 3 adjusting the air flow direc tion refer to figure 6 only for dou ble flow multi flow corner ceiling suspended and wall mounted 12
- 4 programming start and stop of the system with timer refer to figure 9 13
- 5 setting the master remote con troller 13
- 6 precautions for group con trol system or two remote controller control system 14
- Optimum operation 14
- 1 at the beginning of the season 15
- 1 the system does not operate 15
- 2 at the end of the season 15
- 2 it stops sometimes 15
- 3 cool heat cannot be changed over 15
- Following symptoms are not air conditioner troubles 15
- Seasonal maintenance 15
- 10 the units can give off odours 16
- 11 the outside unit fan does not rotate 16
- 5 the fan strength does not cor respond to the setting 16
- 6 the fan direction does not cor respond to the setting 16
- 7 white mist comes out of the unit 16
- 8 noise of air conditioners 16
- 9 dust comes out of the unit 16
- Cooling and heating do not work 16
- Fan operation is possible but 16
- 12 the display shows 17
- 13 the compressor or fan in the outside unit does not stop 17
- 14 the inside of outside unit is warm even when the unit has stopped 17
- 15 hot air is emitted even though the unit is stopped 17
- 16 does not cool very well 17
- Trouble shooting 17
- After sales service and warranty 18
- P215731 1d em07a037a 20
Похожие устройства
- Daikin RXYQ120PYDN Спецификация
- Daikin RXYQ120PYDN Руководство по вводу в эксплуатацию
- Daikin RXYQ120PYDN Инструкция по эксплуатации
- Daikin RXYQ120PYDN Сервис мануал
- Daikin RXYQ120PTJU Сервис мануал
- Daikin RXYQ72PATJ Спецификация
- Daikin RXYQ72PATJ Руководство по вводу в эксплуатацию
- Daikin RXYQ96PATJ Спецификация
- Daikin RXYQ96PATJ Руководство по вводу в эксплуатацию
- Daikin RXYQ108PATJ Спецификация
- Daikin RXYQ108PATJ Руководство по вводу в эксплуатацию
- Sinbo SBG 7102A User guide
- Daikin RXYQ72PATJ Инструкция по монтажу
- Daikin RXYQ72PATJ Инструкция по эксплуатации
- Daikin RXYQ96PATJ Инструкция по монтажу
- Daikin RXYQ96PATJ Инструкция по эксплуатации
- Daikin RXYQ108PATJ Инструкция по монтажу
- Daikin RXYQ108PATJ Инструкция по эксплуатации
- Daikin RXYQ72PAYD Спецификация
- Daikin RXYQ72PAYD Руководство по вводу в эксплуатацию