Daikin VAM1000FA [19/24] Vkm gm

Daikin VAM1000FA [19/24] Vkm gm
VKM50GM VKM80GM VKM100GM
4.71 7.46 9.12
5.58 8.79 10.69
Galvanised steel plate
387 387 387
176 4 176 4 176 4
832 1214 1214
102 120.0 125.0
Sirocco fan
500 750 950
500 750 950
440 640 820
500 750 950
500 750 950
440 640 820
160 140 110
120 90 70
100 70 60
2 x 280 2 x 280 2 x 280
76 78 74
76 78 74
77.5 79 76.5
64 66 62
64 66 62
67 68 66
67 71 65
67 71 65
69 73 69
Natural evaporating type
2.7 4.0 5.4
0.02~0.49 0.02~0.49 0.02~0.49
112
0°C~40°CDB, 80% RH or less
-15°C~40°CDB, 80% RH or less
0°C~40°CDB, 80% RH or less
37.5 39 39.5
35.5 37 37.5
33 34 34.5
37.5 39 39.5
35.5 37 37.5
33 34 34.5
flare connection flare connection flare connection
6.4 6.4 6.4
flare connection flare connection flare connection
12.7 12.7 12.7
6.4 6.4 6.4
PT3/4 external thread
Self-extinguishable urethane foam
Air to air cross flow total heat (sensible + latent heat) exchange
Specially processed non-flammable paper
Multidirectional fibrous fleeces
Ø 200 Ø 250 Ø 250
1~, 50Hz, 220-240V
DX coil capacity Cooling kW
Heating kW
Casing Material
Dimensions Height mm
Width mm
Depth mm
Weight kg
Fan Type
Air flow rate Heat exchange mode Ultra-high m
3
/h
High m
3
/h
Low m
3
/h
Bypass mode Ultra-high m
3
/h
High m
3
/h
Low m
3
/h
External static pressure Ultra-high Pa
High Pa
Low Pa
Motor Output W
Temperature exchange efficiency Ultra-high %
High %
Low %
Enthalpy exchange Cooling Ultra-high %
efficiency High %
Low %
Heating Ultra-high %
High %
Low %
Humidifier System
Amount kg/h
Feed water pressure MPa
N° of elements
Operation range Around unit
Outdoor air
Return air
Sound level - Heat Sound pressure Ultra-high dBA
230V exchange High dBA
mode Low dBA
Bypass mode Sound pressure Ultra-high dBA
High dBA
Low dBA
Piping connection Liquid Type
Diameter mm
Gas Type
Diameter mm
Water supply mm
Drain
Insulation material
Heat exchange system
Heat exchange element
Air filter
Connection duct diameter mm
Power supply V1
VKM-GM
p. 19
Notes: Indoor temperature: 27°CDB, 1CWB, outdoor temperature: 35°CDBIndoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB
Humidifying capacity is based on: Indoor temperature: 20°CDB, 1CWB, outdoor temperature: 7°CDB, 6°CWB
Operation sound is measured at 1.5m below the center of the body.
Sound values are measured in an anechoic chamber built in accordance with JIS C 1502 condition. Operating sound level generally becomes higher than this value depending on the operating conditions, reflected sound, and peripheral noise.
The sound level at the air discharge port is about 8dB higher than the unit’s operating sound.
For operation in a quiet room, it is required to take measures to lower the sound, for example install more than 2m soft duct near the air discharge grill.
Air flow rate can be changed over to Low mode or High mode.
Normal amplitude, input, efficiency depend on the other above conditions
VKM80-100GM
Ventilation, DX coil & humidifier
375 EPCE05-44B UK artwork 26/6/06 12:26 pm Page 19