Daikin VAM350J7VEB [31/35] Air flow rate m³ h

Daikin VAM350J7VEB [31/35] Air flow rate m³ h
3
9
• Ventilation • VAM-J
29
• Indoor Unit • VAM-J
9 Fan characteristics
9 - 1 Fan Characteristics
VAM2000J
Notes
1. The fan curves are determined with ·1/3· of the ESP on the outdoor side (·EA & OA·), and ·2/3· of the ESP on the indoor side (·RA & SA·).
EA = Exhaust air
OA = Outdoor air
RA = Room air
SA = Supply air
Legend
2 Measured according to ·JIS B 8628 - 2003·
L1 = Low speed lower limit
L8 = Low speed factory setting
Ultra-high speed
L15 = Low speed upper limit
High speed
H1 = High speed lower limit
Low speed
H8 = High speed factory setting
H15 = High speed upper limit
UH1 = Ultra-high speed lower limit
UH8 = Ultra-high speed factory setting
UH15 = Ultra-high speed upper limit
0
50
100
150
200
250
300
350
1200 1400 1600 1800 2000 2200
UH1
UH8
UH15
0
50
100
150
200
250
300
1000 1200 1400 1600 1800 2000
H1
H15
H8
0
50
100
150
200
250
800 1000 1200 1400 1600 1800
L8
L1
L15
0
50
100
150
200
250
300
800 1000 1200 1400 1600 1800 2000 2200
2xØ250
30m
60m
90m
150m
120m
L1
L8
L15
H15
UH15
UH1
UH8
H8
H1
Duct length
Ultra-high speed
Low speed
High speed
Air flow rate [m³/h]
External static pressure [Pa]
Air flow rate [m³/h]
Air flow rate [m³/h]
Air flow rate [m³/h]
External static pressure [Pa]
External static pressure [Pa]
External static pressure [Pa]
3D112839