SilverStone ST45NF [13/15] Nj450 manual 12

SilverStone ST45NF [13/15] Nj450 manual 12
Temp. Status LED Color
High > 55 C Yellow
7.1. Mean Time Between failures (MTBF)
The MTBF of the power supply shall be calculated utilizing the Part-Stress Analysis
method of Bellcore
MIL217F. The calculated MTBF of the power supply shall be greater than 100,000
hours under the following conditions:
(a)Full rated load, (b)120V AC input ,(c)Ground Benign;(d) 25 C
8.1. LED Indicators
There are two LEDs for the monitoring the status of the power supply, which allows
users to perceive a full awareness of the working condition of the power supply.
The temperature-LED indicates surface temperature of
the power supply's housing cage.
[CAUTION: DO NOT TOUCH THE SURFACE OF POWER SUPPLY WHEN THE
TEMP.-LED INDICATES YELLOW, IT MIGHT BE DANGEROUS.]
O
O
Low < 55 C
-
-
-
Green
Configure 8-1-1
Power Status LED Color
Configure 8-1-2
The Status-LED indicates power supply' working
Standby Amber
Power ON Green
Power Fault
Red
8.2. AC Input Connector
The AC input receptacle shall be an IEC 320 type or equivalent. The IEC 320 C
receptacle will be considered the mains disconnect.
8.3. DC Wire Harness and Connector Requirements
ATX Motherboard Power Connector
Physical Characteristics Size
o
SST-ST45NF