SilverStone ST75ZF [11/16] St75zf manual 11

SilverStone ST75ZF [11/16] St75zf manual 11
ZEUS ST75ZFZEUS ST75ZF
10
5.4 Mechanical Shock
The power supply (non-operating) shall not be damaged during a shock of 50G with an 11
mS half sin wave, non-operating. The shock to be applied in each of the orthogonal axes.
5.5 Vibration (Operating and Non-operating)
The power supply shall be subjected to a vibration test consisting of a 10 to 300 Hz sweep at
a constantacceleration of 2.0g for duration of one (1) hour for each of the perpendicular axes
X, Y and Z, 0.1 octave/minute. The output voltages shall remain within specification.
6.2 AC Input Leakage Current
Input leakage current from line to ground will be less than 3.5mA rms. Measurement will be
made at 240 VAC and 60Hz.
6. Agency Requirements
6.1 Safety Certification.
Product Safety:
Table 16 -Safety Certification
RFI Emission:
UL 60950 2000Edition, IEC60950, 3
rd
EditionEU
Low Voltage Directive(73/23/EEC) (CB)TUV, CCC
PFC Harmonic:
Flicker:
Immunity against:
-Electrostatic discharge:
-Radiated field strength:
-Fast transients:
-Surge voltage:
-RF Conducted
-Voltage Dips and Interruptions
FCC Part15 (Radiated & Conducted Emissions)CISPR
22,3
rd
Edition/ EN55022 Class B)
EN 61000-3-2
EN55024: 1998
-IEC 61000-4-2 Min. 4kV contact discharge
Min. 8kV air discharge
-IEC 61000-4-3 Min. 10V/m
-IEC 61000-4-4 Min 2kV AC input lines
Min 1kV on data lines
-IEC 61000-4-5 Min 2kV common mode
Min 1kV differential mode
-IEC 61000-4-6
-IEC 61000-4-11
EN 61000-3-3