Ferroli ATLAS 32-95 [12/16] Atlas 95

Ferroli ATLAS 32-95 [12/16] Atlas 95
ATLAS
35
RU
cod. 3540S123 - 07/2010 (Rev. 00)
5. ɏȺɊȺɄɌȿɊɂɋɌɂɄɂ ɂ ɌȿɏɇɂɱȿɋɄɂȿ ȾȺɇɇɕȿ
5.1 Ɋɚɡɦɟɪɵ, ɩɪɢɫɨɟɞɢɧɟɧɢɹ ɢ ɨɫɧɨɜɧɵɟ ɷɥɟɦɟɧɬɵ ɤɨɬɥɚ
ɪɢɫ.5 - Ɋɚɡɦɟɪɵ, ɩɪɢɫɨɟɞɢɧɟɧɢɹ ɢ ɨɫɧɨɜɧɵɟ ɷɥɟɦɟɧɬɵ ɤɨɬɥɚ
a1 ɉɢɬɚɧɢɟ ɫɢɫɬɟɦɵ ɨɬɨɩɥɟɧɢɹ ɝɨɪɹɱɟɣ ɜɨɞɨɣ 3/4
a2 ɒɬɭɰɟɪ ɨɛɪɚɬɧɨɝɨ ɬɪɭɛɨɩɪɨɜɨɞɚ ɫɢɫɬɟɦɵ ɨɬɨɩɥɟɧɢɹ 1 1/2
a3 ɋɥɢɜ ɫɢɫɬɟɦɵ ɨɬɨɩɥɟɧɢɹ - 1/2”
a4 ɉɨɞɤɥɸɱɟɧɢɟ ɞɵɦɨɯɨɞɚ
a5 ɉɨɞɤɥɸɱɟɧɢɟ ɝɨɪɟɥɤɢ
34 ɒɚɪɢɤ ɬɟɪɦɨɦɟɬɪɚ ɫɢɫɬɟɦɵ ɨɬɨɩɥɟɧɢɹ ɢ ɩɪɟɞɨɯɪɚɧɢɬɟɥɶɧɨɝɨ ɭɫɬɪɨɣɫɬɜɚ
5.2 Ƚɢɞɪɚɜɥɢɱɟɫɤɨɟ ɫɨɩɪɨɬɢɜɥɟɧɢɟ ɫɢɫɬɟɦɵ
ɋɨɩɪɨɬɢɜɥɟɧɢɟ ɜɨɞɹɧɨɝɨ ɤɨɧɬɭɪɚ
ɪɢɫ.6 - ɋɨɩɪɨɬɢɜɥɟɧɢɟ ɫɢɫɬɟɦɵ
A ɦɛɚɪ
B Ɋɚɫɯɨɞ ɜɨɞɵ ɥ/ɱ
5.3 Ɍɚɛɥɢɰɚ ɬɟɯɧɢɱɟɫɤɢɯ ɞɚɧɧɵɯ
Ɇɨɞɟɥɶ
°C
ɦɦ
a4
ɒɦɦ
a5
ɒɦɦ
ATLAS 32
400 120ɱ130 115
ATLAS 47
500 120ɱ130 115
ATLAS 62
600 120ɱ130 115
ATLAS 78
700 120ɱ130 115
ATLAS 95
800 120ɱ130 115
500
C
850
245
250 250
250 250
626
705
105
a1
a2
a3
a4
85
105
34
a5
Ɇɨɞɟɥɶ ATLAS
32
ATLAS
47
ATLAS
62
ATLAS
78
ATLAS
95
Ʉɨɥɢɱɟɫɬɜɨ ɷɥɟɦɟɧɬɨɜ n°34567
Ɇɚɤɫ. ɬɟɩɥɨɜɚɹ ɦɨɳɧɨɫɬɶ kW 34.9 51.6 67.7 85.6 103.2 (Q)
Ɇɢɧ. ɬɟɩɥɨɜɚɹ ɦɨɳɧɨɫɬɶ kW 17.0 34.3 45.8 59.0 70.8 (Q)
Ɇɚɤɫ. ɬɟɩɥɨɜɚɹ ɦɨɳɧɨɫɬɶ ɜ ɪɟɠɢɦɟ ɨɬɨɩɥɟɧɢɹ kW 32 47 62 78 95 (P)
Ɇɢɧ. ɬɟɩɥɨɜɚɹ ɦɨɳɧɨɫɬɶ ɜ ɪɟɠɢɦɟ ɨɬɨɩɥɟɧɢɹ kW 16 32 43 55 66 (P)
Ʉɩɞ Pmax (80-60°C) % 91.7 91.1 91.5 91.1 92
Ʉɩɞ 30 % 94.3 93.5 94.0 93.5 93.8
Ʉɥɚɫɫ ɷɮɮɟɤɬɢɜɧɨɫɬɢ ɩɨ ɞɢɪɟɤɬɢɜɟ 92/42 EEC
Ɇɚɤɫɢɦɚɥɶɧɨɟ ɪɚɛɨɱɟɟ ɞɚɜɥɟɧɢɟ ɜɨɞɵ ɜ
ɫɢɫɬɟɦɟ ɨɬɨɩɥɟɧɢɹ
bar66666(PMS)
Ɇɚɤɫɢɦɚɥɶɧɨɟ ɪɚɛɨɱɟɟ ɞɚɜɥɟɧɢɟ ɜɨɞɵ ɜ
ɫɢɫɬɟɦɟ ɨɬɨɩɥɟɧɢɹ
bar 0.8 0.8 0.8 0.8 0.8
Ɇɚɤɫɢɦɚɥɶɧɚɹ ɬɟɦɩɟɪɚɬɭɪɚ ɜ ɫɢɫɬɟɦɟ
ɨɬɨɩɥɟɧɢɹ
°C 95 95 95 95 95 (tmax)
Ɉɛɴɟɦ ɜɨɞɵ ɜ ɫɢɫɬɟɦɟ ɨɬɨɩɥɟɧɢɹ l1823283338
Ʉɥɚɫɫ ɡɚɳɢɬɵ IPX0DX0DX0DX0DX0D
ɇɚɩɪɹɠɟɧɢɟ ɩɢɬɚɧɢɹ V/Hz 230/50 230/50 230/50 230/50 230/50
ȼɟɫ ɩɨɪɨɠɧɟɝɨ ɤɨɬɥɚ kg 127 166 205 244 283
Ⱦɥɢɧɚ ɤɚɦɟɪɵ ɫɝɨɪɚɧɢɹ mm 350 450 550 650 750
Ⱦɢɚɦɟɬɪ ɤɚɦɟɪɵ ɫɝɨɪɚɧɢɹ mm 300 300 300 300 300
ɋɨɩɪɨɬɢɜɥɟɧɢɟ ɞɵɦɨɨɬɜɨɞɹɳɟɝɨ ɬɪɚɤɬɚ mbar0.20.270.4 0.40.63
0
10
20
30
40
50
60
2000 2500 3000 3500 4000 4500 5000 5500
B
A