MAINTENANCE 6 6 1 Troubleshooting PROBLEM No power comes ON No sound comes from the speaker POSSIBLE CAUSE SOLUTION REF Battery pack requires charging Charge the battery pack Poor connection between the battery pack and the transceiver Clean debris from the terminals of the bat tery pack and the transceiver SQL turned too far clockwise Rotate SQL counterclockwise p 8 Battery pack requires charging Charge the battery pack P 2 Power off timer is activated Turn power OFF and ON again p 16 An external speaker or earphone is con nected Unplug speaker or earphone P 2 Battery pack requires charging Charge the battery pack P 2 Low power position is selected Select High output power p 9 Lock function is activated Turn OFF the function p 5 Call channel is selected Push C to return to VFO or MEMORY mode P 11 Only memory channels 0 9 can be used Memory channels 10 47 are in blank status Select a memory channel after pushing FUNC P 12 Scan does not operate Call channel is selected Set in VFO or MEMORY mode Squelch is open Rotate SQL clockwise P 11 p 15 The transceiver is in the special operating condition While pushing LIGHT and V M turn power ON p i The C switch cannot call the call channel The transceiver is in the special operating condition While pushing LIGHT and V M turn power ON p i The contents of the memories are erased The backup battery is exhausted because no charging has been performed for a long time Charge the battery pack backup battery is charged simultaneously p 18 No transmitting is possible or only Low power can be used Frequency cannot be set 17