Daikin EHVZ04S18CB3V — руководство по эксплуатации низкотемпературной системы отопления [2/12]
Превью страниц
Страница 2 /
12
![Daikin EHVZ04S18CB3V [2/12] Operation manual](/views2/1747141/page2/bg2.png)
Table of Contents
Operation manual
2
EHVZ04~16S18CB3V
Daikin Altherma – Low temperature split
4P401675-1B – 2017.04
Table of Contents
1 About this document 2
2 About the system 2
2.1 Components in a typical system layout ..................................... 2
3 Operation 3
3.1 Overview: Operation.................................................................. 3
3.2 The user interface at a glance................................................... 3
3.2.1 Buttons........................................................................ 3
3.2.2 Status icons ................................................................ 3
3.3 Space heating control................................................................ 4
3.3.1 Setting the space operation mode .............................. 4
3.3.2 Room thermostat control - Using the room
temperature home page.............................................. 4
3.3.3 Room thermostat control - Using the leaving water
temperature home pages............................................ 4
3.4 Domestic hot water control........................................................ 4
3.4.1 Reheat mode .............................................................. 4
3.4.2 Scheduled mode ......................................................... 4
3.4.3 Scheduled + reheat mode........................................... 5
3.4.4 Using the DHWtank temperature home page............ 5
3.4.5 Using the DHWtank booster mode ............................ 5
3.5 Advanced usage........................................................................ 5
3.5.1 About changing the user permission level .................. 5
3.6 Schedules: Example.................................................................. 5
3.7 Menu structure: Overview user settings .................................... 7
3.8 Installer settings: Tables to be filled in by installer .................... 8
3.8.1 Quick wizard ............................................................... 8
3.8.2 Space heating control ................................................. 8
3.8.3 Domestic hot water control [A.4] ................................. 8
3.8.4 Contact/helpdesk number [6.3.2]................................ 8
4 Energy saving tips 8
5 Maintenance and service 9
5.1 Overview: Maintenance and service ......................................... 9
5.2 To find the contact/helpdesk number ........................................ 9
6 Troubleshooting 9
6.1 Symptom: You are feeling too cold (hot) in your living room..... 9
6.2 Symptom: The water at the tap is too cold ................................ 9
6.3 Symptom: Heat pump failure..................................................... 9
7 Disposal 10
8 Glossary 10
1 About this document
Thank you for purchasing this product. Please:
▪ Read the documentation carefully before operating the user
interface to ensure the best possible performance.
▪ Request the installer to inform you about the settings that he used
to configure your system. Check if he has filled in the installer
settings tables. If not, request him to do so.
▪ Keep the documentation for future reference.
Target audience
Endusers
Documentation set
This document is part of a documentation set. The complete set
consists of:
▪ General safety precautions:
▪ Safety instructions that you must read before operating your
system
▪ Format: Paper (in the box of the indoor unit)
▪ Operation manual:
▪ Quick guide for basic usage
▪ Format: Paper (in the box of the indoor unit)
▪ User reference guide:
▪ Detailed step-by-step instructions and background information
for basic and advanced usage
▪ Format: Digital files on http://www.daikineurope.com/support-
and-manuals/product-information/
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.
The original documentation is written in English. All other languages
are translations.
Available screens
Depending on your system layout and installer configuration, not all
screens in this document may be available on your user interface.
Breadcrumbs
1
20.0°C >
18.0°C >
7.4.1.1 Room temperature
Comfort (heating)
Eco (heating)
Select
Scroll
Breadcrumbs help you to locate where you are in the menu structure
of the user interface. This document also mentions these
breadcrumbs.
Example: Go to [7.4.1.1]: > User settings > Preset values >
Room temperature > Comfort (heating)
2 About the system
Depending on the system layout, the system can:
▪ Heat up a space
▪ Produce domestic hot water
2.1 Components in a typical system
layout
d
a b
c
e
f
g
BC
A
A Main zone. Example: Living room.
B Additional zone. Example: Bedroom.
C Technical room. Example: Garage.
a Outdoor unit heatpump
b Indoor unit heatpump
c Domestic hot water (DHW) tank
d User interface at the indoor unit
e User interface in the living room, used as room thermostat
Содержание
53- Operation manual
- Ehvz04s18cb ehvz08s18cb ehvz16s18cb
- Daikin altherma low temperature split
- About the system
- Troubleshooting 9
- Table of contents
- Select scroll
- Room temperature
- Operation manual
- Operation 3
- Maintenance and service 9
- Glossary 10
- Energy saving tips 8
- Disposal 10
- Components in a typical system layout
- Comfort heating eco heating
- About this document 2
- About this document
- About the system 2
- Buttons
- The user interface at a glance
- Status icons
- Overview operation
- Operation
- Space heating control
- Setting the space operation mode
- Operation
- Domestic hot water control
- Schedules example
- Operation
- Advanced usage
- Operation
- Menu structure overview user settings
- Information
- Ehvz04 16s18cb3v daikin altherma low temperature split 4p401675 1b 2017 4
- Depending on the selected installer settings settings will be visible invisible
- Operation manual
- Operation
- Space heating control
- Quick wizard
- Installer settings tables to be filled in by installer
- Energy saving tips
- Domestic hot water control a
- Contact helpdesk number 6
- Troubleshooting
- To find the contact helpdesk number
- Symptom you are feeling too cold hot in your living room
- Symptom the water at the tap is too cold
- Symptom heat pump failure
- Overview maintenance and service
- Maintenance and service
- Disposal
- Glossary
Похожие устройства
-
Daikin EVLQ08CAV3Руководство по применению для установщика -
Daikin EVLQ08CAV3Справочное руководство для монтажника -
Daikin EVLQ08CAV3Общие правила техники безопасности -
Daikin EVLQ08CAV3Инструкция по монтажу -
Daikin EVLQ05CAV3Справочное руководство для монтажника -
Daikin EVLQ05CAV3Руководство по применению для установщика -
Daikin EVLQ05CAV3Общие правила техники безопасности -
Daikin EVLQ05CAV3Инструкция по монтажу -
Daikin EHYKOMB33AA3Справочное руководство для монтажника -
Daikin EHYKOMB33AA3Руководство по применению для установщика -
Daikin EHYKOMB33AA3Руководство по эксплуатации -
Daikin EHYKOMB33AA2Руководство по применению для установщика
Изучите руководство по эксплуатации низкотемпературной системы отопления. Узнайте о компонентах, управлении, настройках и обслуживании для эффективного использования.