Daikin EHVX04S18DA3V — схемы подключения и установка внутренних блоков кондиционеров [16/21]
![Daikin EHVX04S18DA3V [16/21] Ehvh d6v ehvh d9w](/views2/1747766/page16/bg10.png)
Содержание
- Technical data p.1
- Heating p.1
- Ehvx d3v p.1
- Daikin p.1
- Table of contents p.3
- Features p.4
- Specifications p.5
- Indoor unit ehvx d3v p.5
- Heating ehvx d3v p.5
- 1 technical specifications p.5
- Specifications p.6
- Indoor unit ehvx d3v p.6
- Heating ehvx d3v p.6
- 2 electrical specifications p.6
- 1 technical specifications p.6
- Specifications p.7
- Indoor unit ehvx d3v p.7
- Heating ehvx d3v p.7
- 2 electrical specifications p.7
- D111982a p.8
- 1 electrical data p.8
- Electrical data p.8
- Ehvz d9w p.8
- Ehvz d6v p.8
- Ehvx d6v ehvx d9w p.8
- Ehvx d3v p.8
- Ehvh d6v ehvh d9w p.8
- Indoor unit ehvx d3v p.9
- Heating ehvx d3v p.9
- Ehvh d6v ehvh d9w ehvh dv ehvx d3v ehvx d6v ehvx d9w ehvz d6v ehvz d9w p.9
- D111985a p.9
- Combination table p.9
- 1 combination table p.9
- Capacity tables p.10
- 1 domestic hot water performance p.10
- Dimensional drawings p.11
- 1 dimensional drawings p.11
- Centre of gravity p.12
- 1 centre of gravity p.12
- Piping diagrams p.13
- Ehvx d9w p.13
- Ehvx d6v p.13
- Ehvx d3v p.13
- Ehvh d9w p.13
- Ehvh d6v p.13
- D111411 p.13
- 1 piping diagrams p.13
- Wiring diagrams p.14
- 1 wiring diagrams single phase p.14
- Wiring diagrams p.15
- 1 wiring diagrams single phase p.15
- Description p.16
- 1 wiring diagrams single phase p.16
- X1m i x2m p.16
- Wiring diagrams p.16
- Position in switch box p.16
- Notes to go through before starting the 1 note 1 connection point of the power unit supply for the buh should be foreseen outside the unit p.16
- Legend p.16
- K5m kim k2m q1l p.16
- Ehvx d6v ehvx d9w p.16
- Ehvx d3v p.16
- Ehvh d6v ehvh d9w p.16
- H_________ p.17
- Fifidsuppiy p.17
- Field supply p.17
- External room thermostat i heat pump convector main and or additional zone optional part p.17
- External connection diagrams p.17
- Aâîsxâùlm z 5 p.17
- 1 external connection diagrams p.17
- Xpm 3 1 p.17
- X5n s d p.17
- Way valve p.17
- Indoor unit p.17
- Installation p.18
- Indoor unit ehvx d3v p.18
- Heating ehvx d3v p.18
- 1 installation method p.18
- Hydraulic performance p.19
- 1 static pressure drop unit p.19
- Water flow rate l min p.20
- Hydraulic performance p.20
- Ehvh d6v ehvh d9w ehvh dv ehvx d3v ehvx d6v ehvx d9w p.20
- D112012 p.20
- 1 static pressure drop unit p.20
Похожие устройства
-
Daikin EVLQ08CAV3Руководство по применению для установщика -
Daikin EVLQ08CAV3Справочное руководство для монтажника -
Daikin EVLQ08CAV3Общие правила техники безопасности -
Daikin EVLQ08CAV3Инструкция по монтажу -
Daikin EVLQ05CAV3Справочное руководство для монтажника -
Daikin EVLQ05CAV3Руководство по применению для установщика -
Daikin EVLQ05CAV3Общие правила техники безопасности -
Daikin EVLQ05CAV3Инструкция по монтажу -
Daikin EHYKOMB33AA3Справочное руководство для монтажника -
Daikin EHYKOMB33AA3Руководство по применению для установщика -
Daikin EHYKOMB33AA3Руководство по эксплуатации -
Daikin EHYKOMB33AA2Руководство по применению для установщика
I Indoor Unit EHVX D3V 9 Wiring diagrams 9 1 Wiring Diagrams Single Phase EHVH D6V EHVH D9W EHVX D3V EHVX D6V EHVX D9W 9 NOTES to go through before starting the 1 NOTE 1 Connection point of the power unit supply for the BUH should be foreseen outside the unit VIM POSITION IN SWITCH BOX SWB1 MAM X2M Field wiring terminal for AC Backup heater 3V 1 N 230V 3kW X5M Field wiring terminal for DC power supply 6T1 3 230V 6kW X6M BUH Power supply terminal TRI 6V 1N 230V 6kW 6WW9WN 3N 400V 6 9kW Earth wiring 1 1 1 X5M 1 Domestic hot water lank о_____ 1 oeverai wiring possibilities О Rpmntp tt tpr intpfacp 1 Ext indoor thermistor Option Digital I O PCB A8P A1P Ext outdoor thermistor i__________ i X2M user installed options LAN adapter Field supply X1M I A4P Demand PCB Main LWT Wiring depending on model ON OFF thermostat wired A1OP ON OFF thermostat wireless Not mounted in switch box K5M KIM K2M Ext thermistor Q1L Heat pump convector Add LWT PQB ON OFF thermostat wired SWB2 ON OFF thermostat wireless Ext thermistor Heat pump convector LEGEND optional field supply Description Partn Description Partn A1P main PCB M2P ON OFF thermostat PC power circuit M2S heat pump convector M3S digital I O PCB P1M demand PCB PC A15P A9P status indicator PHC1 A4P A10P MMIPSUPCB Q1L A11P MMI main PCB Q4L safety thermostat A12P MMI display PCB Q DI earth leakage circuit breaker LAN adapter R1H A2P user interface PCB R1T A1P receiver PCB wireless ON OFF thermostat R1T A2P B1L flow sensor R1T A14P B1PR refrigerant pressure sensor R2T A1P B1PW water pressure sensor R2T A2P connector R3T refrigerant liquid side thermistor dipswitch R4T inlet water thermistor E1H backup heater element 1 kW R5T R8T E2H backup heater element 2 kW R6T external indoor or outdoor ambient thermistor E3H backup heater element 3 kW S1S preferential kWh rate PS contact E P A9P indication LED S2S electrical meter pulse input 1 F1B overcurrent fuse backup heater S3S electrical meter pulse input 2 F1T thermal fuse backup heater S6S S9S fuse 5 A 250 V for digital I O PCB SS1 A4P FU1 A1P fuse T5A 250Vfor PCB SW1 2 A12P turn buttons FU2 A10P fuse T 1 6 A 250 V for PCB SW3 5 A12P push button K1M K2M contactor backup heater TR1 K5M safety contactor BUH X6M K R A1P A4P relay on PCB X X A J X H X Y connector M1P main supply pump X M terminal strip A2P A3P A4P ASP A13P A14P A15P CN A4P DS1 A8P F1U F2U A4P domestic hot water pump 2 way valve for cooling mode 3 way valve for floorheating domestic hot water MMI display power circuit optocoupler input circuit thermal protector backup heater humidity sensor outlet water heat exchanger thermistor ambient sensor ON OFF thermostat ambient sensor user interface outlet backup heater thermistor external sensor floor or ambient domestic hot water thermistor digital power limitation inputs selector switch power supply transformer BUH power supply terminal strip 4D109675C 14 I DAIKIN Heating EHVX D3V
Изучите схемы подключения и установки внутренних блоков кондиционеров. Подробные инструкции и советы по подключению различных компонентов и термостатов.