7 Disposal
Operation manual
9
EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596819-1 – 2019.10
6.2 Symptom: You are feeling too cold
(hot) in your living room
Possible cause Corrective action
The desired room temperature is
too low (high).
Increase (decrease) the desired
room temperature. See
"3.3.2Room thermostat control -
Using the room temperature
home pages"[46].
If the problem recurs daily, do
one of the following:
▪ Increase (decrease) the room
temperature preset value. See
the user reference guide.
▪ Adjust the room temperature
schedule. See "3.5Schedules:
Example"[47].
The desired room temperature
cannot be reached.
Increase the desired leaving
water temperature in accordance
with the heat emitter type. See
"3.3.3Room thermostat control -
Using the leaving water
temperature home pages"[46].
The weather-dependent curve is
set incorrectly.
Adjust the weather-dependent
curve. See the user reference
guide.
6.3 Symptom: The water at the tap is
too cold
Possible cause Corrective action
You ran out of domestic hot
water because of unusual high
consumption.
If you immediately need domestic
hot water, activate the DHWtank
booster mode. However, this
consumes extra energy. See
"3.4.5Using the DHWtank
booster mode"[47].
If you can wait, overrule
(increase) the active or next
scheduled desired temperature
so that more hot water will be
produced exceptionally. See "To
read out and overrule the active
or next scheduled desired
temperature (in scheduled mode
or scheduled + reheat
mode)"[47].
If the problem recurs daily, do
one of the following:
▪ Increase the DHW tank
temperature preset value. See
the user reference guide.
▪ Adjust the DHW tank
temperature schedule.
Example: Program to
additionally heat up the
DHW tank to a preset value
(Storage eco = lower tank
temperature) during the day.
See "3.5 Schedules:
Example"[47].
The desired DHWtank
temperature is too low.
6.4 Symptom: Heat pump failure
When the heat pump fails to operate, the backup heater can serve
as an emergency heater and either automatically or non-
automatically take over the heat load.
▪ When auto emergency is activated and a heat pump failure
occurs, the backup heater will automatically take over the heat
load.
▪ When auto emergency is not activated and a heat pump failure
occurs, the domestic hot water and space heating operations will
stop and need to be recovered manually. The user interface will
then ask you to confirm whether the backup heater can take over
the heat load or not.
When the heat pump fails,
will appear on the user interface.
Possible cause Corrective action
Heat pump is damaged. ▪ Press to view a description
of the problem.
▪ Press
again.
▪ Select
to allow the backup
heater to take over the heat
load.
▪ Call your local dealer to get
the heat pump fixed.
INFORMATION
When the backup heater takes over the heat load,
electricity consumption will be considerably higher.
6.5 Symptom: The system is making
gurgling noises after
commissioning
Possible cause Corrective action
There is air in the system. Purge air from the system.
(a)
Various malfunctions. Check if is displayed on the
home pages of the user
interface. You can press
to
display more information about
the malfunction.
(a)
We recommend to purge air with the air purge function
of the unit (to be performed by the installer). If you purge
air from the heat emitters or collectors, mind the
following:
WARNING
Air purging heat emitters or collectors. Before you
purge air from heat emitters or collectors, check if an error
or
is displayed on the home pages of the user interface.
▪ If not, you can purge air immediately.
▪ If yes, make sure that the room where you want to
purge air is sufficiently ventilated. Reason: Refrigerant
might leak into the water circuit, and subsequently into
the room when you purge air from the heat emitters or
collectors.
7 Disposal
NOTICE
Do NOT try to dismantle the system yourself: dismantling
of the system, treatment of the refrigerant, oil and other
parts MUST comply with applicable legislation. Units
MUST be treated at a specialised treatment facility for
reuse, recycling and recovery.
Содержание
- Daikin altherma 3 r f 1
- Ehfz03s18dj3v 1
- Operation manual 1
- Alarm output 2
- Bottom plate heater 2
- Buh step 1 2
- Capacities energy metering a 2
- Contact helpdesk number 2
- Contact helpdesk number 6 2
- Contact type add 2
- Contact type main 2
- Demand pcb 2
- Demand pcb a 2
- Dhw operation 2
- Dhw pump 2
- Dhw tank type 2
- Digital i o pcb a 2
- Disposal 9 2
- Domestic hot water control a 2
- Domestic hot water settings a 2
- Emitter type 2
- Energy metering a 2
- Energy saving tips 8 2
- Ext backup heat src 2
- External kwh meter 1 2
- External kwh meter 2 2
- External sensor 2
- Forced off contact 2
- Forced off contact a 2
- General information 3 2
- Glossary 10 2
- Heating 2
- In case of frequent domestic hot water operation frequent and long space heating interruption will happen 2
- Information 2
- Installer settings tables to be filled in by installer 2
- Installer settings tables to be filled in by installer 2 2
- Leaving water temperature additional zone a 2
- Leaving water temperature delta t source a 2
- Leaving water temperature emitter type a 2
- Leaving water temperature main zone a 2
- Leaving water temperature modulation a 2
- Lwt setpoint mode 2
- Maintenance and service 8 2
- Maximum setpoint 2
- Modulated lwt 2
- Number of lwt zones 2
- Operation 3 2
- Operation manual 2
- Pump operation mode 2
- Quick wizard 2
- Setting fill in 2
- Space heating control 2
- Space heating settings a 2
- Table of contents 2
- There is a risk of a space heating capacity shortage comfort problem when selecting 6 0d 0 a domestic hot water type reheat only 2
- Thermostats a 2
- Troubleshooting 8 2
- Unit control method 2
- User interface location 2
- About the system 3
- About this document 3
- Buttons 3
- Components in a typical system layout 3
- General information 3
- Operation 3
- User interface overview 3
- Operation 4
- Status icons 4
- User permission level 4
- Depending on the selected installer settings and unit type settings will be visible invisible 5
- Ehfz03s18dj3v daikin altherma 3 r f 4p596819 1 2019 0 5
- Information 5
- Menu structure overview user settings 5
- Operation 5
- Operation manual 5
- Domestic hot water control 6
- Operation 6
- Space heating control 6
- Operation 7
- Schedules example 7
- Energy saving tips 8
- Maintenance and service 8
- Overview maintenance and service 8
- To check the error history 8
- To find the contact helpdesk number 8
- Troubleshooting 8
- Disposal 9
- Symptom heat pump failure 9
- Symptom the system is making gurgling noises after commissioning 9
- Symptom the water at the tap is too cold 9
- Symptom you are feeling too cold hot in your living room 9
- Glossary 10
- Copyright 2019 daikin 12
- P596819 1 12
- Verantwortung für energie und umwelt 12
Похожие устройства
- Daikin EHFZ03S18DA3V Инструкция по эксплуатации
- Daikin EHFZ03S18DJ3V Руководство по эксплуатации
- Daikin EHFZ03S18DA3V Руководство по эксплуатации
- Daikin EABH16DF6V Технические данные
- Daikin EABH16DF6V Инструкция по монтажу
- Daikin EABH16DA6V Технические данные
- Daikin EABH16DF6V Справочное руководство для установщика
- Daikin EABH16DF6V Руководство для установщика
- Daikin EABH16DA6V Инструкция по монтажу
- Daikin EABH16DF6V Инструкция по эксплуатации
- Daikin EABH16DA6V Справочное руководство для установщика
- Daikin EABH16DF6V Руководство по эксплуатации
- Daikin EABH16DF6V Руководство по применению
- Daikin EABH16DA6V Руководство для установщика
- Daikin EABH16DA6V Инструкция по эксплуатации
- Daikin EABH16DA6V Руководство по эксплуатации
- Daikin EABH16DA6V Руководство по применению
- Moulinex JU5708 Руководство по эксплуатации
- Kocateq EFWFT8LAD1 Инструкция по эксплуатации
- Kocateq EF521 Инструкция по эксплуатации