4. Handling Errors and Problems
Care and maintenance
4. Handling Errors and Problems
4.1 Error Messages
Note: If you change your posture, or move, during measurement, the Posture
symbol ( ) or Movement symbol ( ) may be displayed during
measurement.
Error Display Cause Remedy
Movement during
measurement
Check that the Heartbeat symbol
( ) is lit, then keep still and repeat
measurement.
(Refer to Chapter 3.3)
If the EE appears again, use again,
refer to Chapter 3.4.
Is the arm placed through
the arm cuff correctly?
Place your arm correctly.
(Refer to Chapter 3.2)
Are rolled up sleeves
squeezing the arm?
Remove clothing from your upper
arm and place your arm through the
cuff. (Refer to Chapter 3.2)
Is air leaking from the arm
cuff?
Contact your OMRON distributor or
Customer Services as mentioned
on the package.
Movement during
measurement
Check that the Heartbeat symbol
( ) is lit, then keep still and repeat
measurement.
Arm cuff has been inflated
above 299 mmHg.
Do not inflate the arm cuff above
299 mmHg.
(Refer to Chapter 3.4)
A malfunction has
occurred.
Contact your OMRON distributor or
Customer Services as mentioned
on the package.
EE displayed in the
systolic pressure
area.
E displayed in the
systolic pressure
area.
EE displayed.
Er displayed.
HEM-1040-E.book 36 ページ 2011年12月20日 火曜日 午後1時43分

Содержание

HEM 1040 E book 36 20 11 12 2 00 ABB 1954 3 4 Handling Errors and Problems 4 1 Error Messages Error Display OC8 fi Cause Movement during measurement Check that the Heartbeat symbol V is lit then keep still and repeat measurement Refer to Chapter 3 3 If the EE appears again use again refer to Chapter 3 4 Is the arm placed through the arm cuff correctly Place your arm correctly Refer to Chapter 3 2 Are rolled up sleeves squeezing the arm Remove clothing from your upper arm and place your arm through the cuff Refer to Chapter 3 2 Is air leaking from the arm cuff Contact your OMRON distributor or Customer Services as mentioned on the package Movement during measurement Check that the Heartbeat symbol is lit then keep still and repeat measurement Arm cuff has been inflated above 299 mmHg Do not inflate the arm cuff above 299 mmHg Refer to Chapter 3 4 A malfunction has occurred Contact your OMRON distributor or Customer Services as mentioned on the package EE displayed in the systolic pressure area _ i SA E displayed in the systolic pressure area 0 Œ ha Remedy EE displayed 1 Er displayed Note If you change your posture or move during measurement the Posture symbol Q or Movement symbol J may be displayed during measurement