Daikin D2CND024A1AB [3/16] Safety instructions
![Daikin D2CND024A1AA [3/16] Safety instructions](/views2/1761618/page3/bg3.png)
2 Safety instructions
Operation manual
3
D2CND024A1/4AB + D2TND012~024A4AB
Wall-mounted condensing boiler
3P469438-3M – 2019.11
INFORMATION
Indicates useful tips or additional information.
2 Safety instructions
Always observe the following safety instructions and regulations.
2.1 Installation
WARNING
Installation, service, maintenance and repair of the boiler
can only be carried out by suitably qualified competent
persons, in accordance with the applicable legislation,
regulations, rules and guidelines.
WARNING
The unit may only be operated with its casing properly
mounted. Otherwise, in unfavourable conditions, material
damage or even injury or death can result.
CAUTION
A discharge pipe must be connected to the condensate
trap in order to prevent contact with the condensate.
In case your skin comes into contact with condensate, the contact
location should be washed with plenty of water. Condensate liquid
must never be used for purposes of cleaning, watering plants, or
drinking.
2.2 Smell of gas
DANGER
This is a gas unit. Gas leaks might lead to poisoning and
explosions.
If you smell gas:
▪ Do not use any electrical switches, including light switches.
▪ Do not use telephones in the affected area.
▪ Do not use naked flames, such as matches or lighters.
▪ Do not smoke.
▪ Turn off the main gas supply.
▪ Open windows and doors.
▪ Warn other people in the building.
▪ Get out of the building.
▪ Inform your gas supplier, service agent or other competent
person.
2.3 Modifications on the unit
DANGER
Malfunctions can lead to poisoning and explosions. Never
put the safety devices out of operation, nor tamper with
them so as to impair their function.
CAUTION
An inappropriate modification may cause damage. Never
tamper with the boiler or other parts of the system. Never
attempt to perform maintenance or repair yourself. Call a
qualified service agent.
CAUTION
Do not use sprays, solvents, chlorinated cleaning agents,
paint, and adhesives in the vicinity of the unit. These
substances can cause corrosion, even in the flue system.
DANGER
Do not damage or remove any seals on components. Only
qualified persons are allowed to alter sealed components.
Do not make any modifications on:
▪ Boiler
▪ Gas, water or power supply
▪ Flue system
2.4 Gas conversion
WARNING
Never attempt to do gas conversion yourself. Only qualified
persons can do gas conversion. Contact your service
agent.
This unit is able to be operated with both natural gas and LPG. The
preset gas type is indicated on the identification label of your unit. If
you desire to use your unit with the other fuel type, contact your
service agent.
2.5 For the user
CAUTION
Any misuse is forbidden. The manufacturer is not
responsible for any malfunctions and/or damage that may
occur due to misuse.
▪ Your unit is intended as a heater for central heating systems and
for domestic hot water generation. Any other use is considered as
"misuse".
▪ If you are not sure how to operate the unit, contact your service
agent.
▪ This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in
a safe way and understand the hazards involved. Children shall
NOT play with the appliance. Cleaning and user maintenance
shall NOT be made by children without supervision.
CAUTION
Do not rinse the unit. This may cause electric shocks or
fire.
NOTICE
▪ Do not place any objects or equipment on top of the
unit.
▪ Do not sit, climb or stand on the unit.
Содержание
- Operation manual 1
- Wall mounted condensing boiler 1
- A control unit which contains a user interface controls the ignition safety systems and other actuators user interaction is provided via that user interface which is composed of an lcd screen push buttons and two dials and which is located on the front cover of the unit 2
- About the documentation 2
- About the unit 2
- And cover very important topics follow them carefully 2
- Away from the building call the national gas 2
- Brooklands weybridge surrey 2
- Caution 2
- Contact 10 2
- Contact information 2
- D2cnd024a1ab d2cnd024 instantaneous internal 2
- D2cnd024a4ab d2cnd024 instantaneous external 2
- D2tnd012a4ab d2tnd012 storage tank external 2
- D2tnd018a4ab d2tnd018 storage tank external 2
- D2tnd024a4ab d2tnd024 storage tank external 2
- Daikin uk 2
- Danger 2
- Emergency service on 0800 111 999 2
- Energy saving tips 10 2
- Error codes 10 2
- Filling loop 2
- Following information is only applicable for uk 2
- Homeowner helpdesk 0845 641 9271 2
- If you smell gas 2
- Indicates a situation that could result in death or serious injury 2
- Indicates a situation that could result in equipment or property damage 2
- Indicates a situation that could result in minor or moderate injury 2
- Indicates a situation that results in death or serious injury 2
- Introduction 2
- Introduction 2 2
- Kt13 0ny 2
- L p g boilers call the supplier s number on the side of 2
- Languages are translations 2
- Made to configure your system 2
- Maintenance and cleaning 10 2
- Meaning of warnings and symbols 2
- Model type domestic hot water 2
- Notice 2
- Operation 4 2
- Operation manual 2
- Period of use 2
- Please keep this manual for future reference throughout the unit s 2
- Please read the instructions in the manual carefully for your 2
- Request the installer to inform you about the settings that he 2
- Safety and health 2
- Safety instructions 3 2
- Supply 2
- Table of contents 2
- Technical helpdesk 0845 641 9277 2
- Tel 0845 641 9000 2
- The gas tank 2
- The heights 2
- The instructions contained in this document are intended to guide you through the operation of the unit damage caused by non observance of these instructions are not under the responsibility of daikin 2
- The original documentation is written in english all other 2
- The precautions described in this document are written for users 2
- This daikin unit is a wall mounted gas fired condensing boiler that can supply heat to central heating systems as well as supply domestic hot water depending on settings it is possible to use the unit solely for hot water or solely for central heating hot water supply type can be instantaneous or by means of a hot water storage tank heating only boilers do not supply domestic hot water the type of the boiler can be recognised from the model name written on the identification label which is located at the right cover of the unit see table below 2
- Warning 2
- For the user 3
- Gas conversion 3
- Installation 3
- Modifications on the unit 3
- Safety instructions 3
- Smell of gas 3
- About the low water temperature function 4
- Buttons and dials 4
- Lcd screen 4
- Operating the unit 4
- Operation 4
- Status indicator 4
- To switch on the unit 4
- User interface 4
- About the electronic gas adaptive system calibration 5
- About the home screen 5
- Basic usage 5
- Operation 5
- Possible operation modes 5
- To select the operation mode 5
- About the central heating eco mode 6
- Changing temperature setpoints 6
- Operation 6
- Possible central heating operation modes 6
- To change the central heating temperature setpoint 6
- To change the domestic hot water setpoint 6
- About energy metering function 7
- About the boiler frost protection 7
- About the domestic hot water comfort mode 7
- About the domestic hot water operation 7
- Error handling 7
- Operation 7
- Info menu 8
- Info menu parameters 8
- Menu functions 8
- Operation 8
- To use menu level 1 8
- To use the info menu 8
- Operation 9
- To use the user settings menu 9
- User settings menu 9
- User settings menu parameters detailed 9
- User settings menu parameters short 9
- Contact 10
- Energy saving tips 10
- Error codes 10
- Installer settings menu 10
- Maintenance and cleaning 10
- To clean the outer surface of the unit 10
- Error codes 11
- D2cnd024a1 4ab d2tnd012 024a4ab 12
- Error codes 12
- Operation manual 12
- P469438 3m 2019 1 12
- Wall mounted condensing boiler 12
- D2cnd024a1 4ab d2tnd012 024a4ab wall mounted condensing boiler 3p469438 3m 2019 1 13
- Error codes 13
- Operation manual 13
- Service 0 2 13
- Service 01 13
- Service 03 13
- Service 04 13
- Service 05 13
- Service 06 13
- Service 07 13
- Service 08 13
- Service 09 13
- Service 10 13
- Error codes 14
- Copyright 2018 daikin 16
- Daikin isitma ve soğutma si stemleri san ti c a ş 16
- P469438 3m 16
Похожие устройства
- Daikin D2CND024A1AB Руководство по эксплуатации
- Daikin D2CND024A1AA Инструкция по эксплуатации
- Daikin D2CND024A1AA Руководство по эксплуатации
- Daikin D2CND028A1AB Инструкция по эксплуатации
- Daikin D2CND028A1AB Руководство по эксплуатации
- Daikin D2CND035A1AB Инструкция по эксплуатации
- Daikin D2CND035A1AB Руководство по эксплуатации
- Daikin D2CND028A1AA Инструкция по эксплуатации
- Daikin D2CND028A1AA Руководство по эксплуатации
- Daikin D2CND035A1AA Инструкция по эксплуатации
- Daikin D2CND035A1AA Руководство по эксплуатации
- Daikin D2CND024A4AB Инструкция по эксплуатации
- Daikin D2CND024A4AB Руководство по эксплуатации
- Daikin D2CND024A4AA Инструкция по эксплуатации
- Daikin D2CND024A4AA Руководство по эксплуатации
- Daikin D2CND028A4AB Инструкция по эксплуатации
- Daikin D2CND028A4AB Руководство по эксплуатации
- Daikin D2CND028A4AA Инструкция по эксплуатации
- Daikin D2CND028A4AA Руководство по эксплуатации
- Daikin D2CND035A4AB Инструкция по эксплуатации
Скачать
Случайные обсуждения