Optimus Drive PDM20-2S1R5 [17/54] Terminal instruction

Optimus Drive PDM20-2S1R5 [17/54] Terminal instruction
PDM20 Series
- 16 -
2.5.2 Terminal instruction
Terminal
symbol
Terminal name Technical data
M1
Multi-function
input terminal 1
Enabled when connected to GND; Disabled when open
M2
Multi-function
input terminal 2
Enabled when connected to GND; Disabled when open
AI
Analog input
terminal 1
It is 010V analog voltage input terminal or 4-20mA
analog current input terminal, chosen by function codes.
+Vo
Positive terminal
of analog power
+5V+24V adjustable power; Output voltage value is set
by function codes.
GND
Negative terminal
of analog power
Reference zero potential of +5V+24V adjustable power
2.6 Wiring of Sensors
2.6.1 Terminal instruction
+VO ---524V Power terminal for transmissible pressure gauge/pressure
transmitter
AI ---010V analog signal input terminal (voltage feedback type) or 420mA
signal input terminal (current feedback type)
GND --- 524V signal common terminal
2.6.2 Sensor configuration instruction
A current type pressure sensor will be used by default; output signal is 4~20mA.
If use other types of sensors, please refer to the setting parameters
P0.03P0.04P0.05 in Chapter 4.5.
2.6.3 Wiring diagram
The drive can be connected to transmissible pressure gauge and pressure transmitter.
Please connect wire according to below diagrams.