Daikin EKHVMYD50ABV1 [10/28] Manual storage

Daikin EKHVMYD80ABV1 [10/28] Manual storage
Operation manual
9
EKHVMRD50+80ABV1 + EKHVMYD50+80ABV1
Daikin Altherma indoor unit
4P404418-1 2015.04
Manual storage
This mode is to be selected manually and will make the indoor unit
immediately deliver hot water to the domestic hot water tank. This
mode will continue until the storage temperature set point is reached.
It is a one-time hot water making feature.
Selecting manual storage operation for domestic water heating
1 Push and hold the button for 5 seconds to activate manual
storage operation.
The icon will start blinking with 1 second intervals.
The storage temperature set point is a eld setting. Refer to
"4.15. Field settings" on page 19 for a detailed description how to set
one or more eld settings.
[b-03] set point: storage temperature (see gure "Domestic
water heating modes" on page 8) only valid if [b-02]=0.
[b-02] Status: denes whether the weather dependent domestic
water heating is turned ON (1) or OFF (0).
If enabled, the storage set point will be set weather dependent.
In case of a higher ambient temperature (e.g. during summer-
time), temperature of supply water to the domestic hot water
tank will be higher too, so that storage temperature set point can
be set lower in order to keep the overall equivalent hot water
amount the same during the whole year. Therefor it is
recommended to use this function.
[b-04] Automatic maximum domestic hot water storage
temperature: default = 70°C.
Manual storage is deactivated automatically when the set point for
the domestic hot water storage temperature is reached. It can also be
stopped at any time by pushing the button.
Reheat
This mode will prevent the domestic hot water from cooling down
lower than a certain temperature. When enabled the indoor unit will
deliver hot water to the domestic hot water tank when the reheat
minimum value is reached. The domestic water heating will continue
until the reheat maximum temperature is reached.
Selecting reheat operation for domestic water heating
1 Use the button to enable reheat operation.
The icon will display.
2 Press the button again to disable reheat operation.
The icon disappears.
The reheat minimum and reheat maximum temperature set points
are eld settings. Refer to "4.15. Field settings" on page 19 for a
detailed description how to set one or more eld settings.
[b-00] Set point: reheat minimum temperature (see gure
"Domestic water heating modes" on page 8).
[b-01] Set point: reheat maximum temperature (see gure
"Domestic water heating modes" on page 8).
Disinfection operation
This mode will disinfect the domestic hot water tank by periodically
heating the domestic water to a specic temperature. During the
operation of this mode the icon will be blinking rapidly with 0.5
second intervals.
The disinfection temperature set point is a eld setting as are the
retention time, day and hour. Refer to "4.15. Field settings" on
page 19 for a detailed description how to set one or more eld
settings.
[4-00] Status: denes whether the disinfection function is turned
ON (1) or OFF (0).
[4-01] Operation interval: day of the week at which the domestic
water should be heated.
[4-02] Start time: time at which the disinfection operation is
started.
[5-00] Set point: Disinfection water temperature to be reached
(see gure "Domestic water heating modes" on page 8).
[5-01] Duration: time period dening how long the disinfection
set point temperature should be maintained.
Even if all schedule timers are de-activated and there is no reheat
function active, the disinfection function will operate if a domestic hot
water tank is installed and eld setting [4-00] is set to ON.
NOTE
Remark that the icon will only be blinking
during effective operation.
During the operation it is always possible to
cancel the operation by pushing the button
once.
Be aware that after pushing the button, it is
possible that the permanently lit icon still
displays, meaning that the reheat function is
enabled.
A Ambient temperature
T Domestic hot water storage temperature
NOTE
The ambient temperatures for weather dependent
domestic water heating (see gure) are xed and can
not be changed.
NOTE
If weather dependent domestic water heating is
enabled [b-02], the storage temperature will be set
automatically and the eld setting [b-03] will be of no
importance.
T
A
[b-04]
55°C
15°C25°C
NOTE
Remark that the icon will be continuously lit as
long as the reheat function is enabled. It is not
possible to see when the indoor unit is reheating
the domestic hot water tank.
NOTE
Remark that pushing the button has no inuence
on the domestic water heating. Domestic water heating
is only switched on or off by means of the button
and/or disabling the storage schedule timer.
NOTE
Remark that the icon will only be blinking during
effective operation.
During the operation it is always possible to cancel the
disinfection function by pushing the button once.
Be aware that after pushing the button, it is possible
that the permanently lit icon still displays, meaning
that the reheat function is enabled.
NOTE
If a domestic hot water tank is installed, the disinfection
function is enabled by default.