Daikin EKHVMYD50ABV1 [20/28] Field settings

Daikin EKHVMRD50ABV1 [20/28] Field settings
Operation manual
19
EKHVMRD50+80ABV1 + EKHVMYD50+80ABV1
Daikin Altherma indoor unit
4P404418-1 2015.04
4.15. Field settings
The conguration of the Daikin system is done through eld settings.
In this operation manual all eld settings related to the operation of
the unit and user demand are explained. A list of all those eld
settings and default values is given under "4.16. Field settings table"
on page 20. In this same list, we provided for 2 columns to register
the date and value of altered eld settings at variance with the default
value.
For a total list of eld settings, refer to the installation manual.
All eld settings are accessible and programmable through the user
interface on the indoor unit.
Each eld setting is assigned a 3-digit number or code, for example
[5-03], which is indicated on the user interface display. The rst digit
[5] indicates the 'rst code' or eld setting group. The second and
third digit [03] together indicate the 'second code'.
Procedure
To change one or more eld settings, proceed as follows.
1 Press the button for a minimum of 5 seconds to enter FIELD
SET MODE.
The icon (3) will be displayed. The current selected eld
setting code is indicated (2), with the set value displayed to
the right (1).
2 Press the button to select the appropriate eld setting
rst code.
3 Press the button to select the appropriate eld setting
second code.
4 Press the button and button to change
the set value of the select eld setting.
5 Save the new value by pressing the button.
6 Repeat step 2 through 4 to change other eld settings as
required.
7 When nished, press the button to exit FIELD SET MODE
.
NOTE
Changes made to a specic eld setting are only
stored when the button is pressed. Navigating to a
new eld setting code or pressing the button will
discard the change made.
NOTE
Before shipping, the set values have been set as
shown under "4.16. Field settings table" on
page 20.
When exiting FIELD SET MODE, "88" may be
displayed on the remote controller LCD while the
unit initializes itself.
2
3
1
When running through the eld settings you may
notice that there are some more eld settings as there
are mentioned in the "4.16. Field settings table" on
page 20. These eld settings are not applicable
and may not be changed!
For more information about installation related setting,
see installation manual of the indoor unit. For settings
different from the default value, contact your installer.

Содержание