Daikin EKHVMYD50ABV1 [4/28] Remote controller buttons and icons
![Daikin EKHVMYD50ABV1 [4/28] Remote controller buttons and icons](/views2/1763853/page4/bg4.png)
Operation manual
3
EKHVMRD50+80ABV1 + EKHVMYD50+80ABV1
Daikin Altherma indoor unit
4P404418-1 – 2015.04
Domestic water heating operation
Manual storage
4. O
PERATION
OF
THE
UNIT
The remote controller offers full control over your installation. It can
control all heating applications which vary in capacity, electrical
supply and installed equipment (options). Operating the EKHVMRD
and EKHVMYD unit comes down to operating the remote controller.
4.1. Remote controller buttons and icons
1.
ON/OFF BUTTON
The ON/OFF button starts or stops the space heating/cooling.
Pressing the ON/OFF button consecutively too many times may
cause malfunction of the system (maximum 20 times per hour).
2.
OPERATION LED
The operation LED is lit during space heating/cooling operation.
The LED blinks if a malfunction occurs. When the LED is OFF,
space heating/cooling is inactive while an other operation mode
can still be active.
3.
OPERATION MODE ICONS
,
,
,
These icons indicate the current operation mode(s): space
heating (
), space cooling (
), domestic water heating (
) or
quiet mode (
). Within limits, different modes can be
combined, e.g. space heating and domestic water heating. The
corresponding mode icons will be displayed simultaneously.
If the domestic hot water tank is not installed, the
icon will
never be displayed.
4.
EXTERNAL CONTROL ICON
This icon indicates that the outdoor unit is working in a forced
operation. As long as this icon is displayed, the remote controller
cannot be operated.
5.
DAY OF THE WEEK INDICATOR
This indicator shows the current day of the week.
When reading or programming the schedule timer, the indicator
shows the set day.
6.
CLOCK DISPLAY
The clock display shows the current time.
When reading or programming the schedule timer, the clock
display shows the action time.
7.
SCHEDULE TIMER ICON
This icon indicates that the schedule timer is enabled.
8.
ACTION ICONS
These icons indicate the programming actions for each day of
the schedule timer.
9.
OFF ICON
This icon indicates that the OFF action is selected when
programming the schedule timer.
10.
INSPECTION REQUIRED
and
These icons indicate that inspection is required on the
installation. Consult your dealer.
Domestic water heating (only if domestic hot water tank option is installed)
Automatic storage (daily water heat-up, once during night and/or once during
day)
Turn on field setting [1-00]
and or [1-02] and then push
the
button.
See "Automatic storage" on
page 8.
The
icon will display.
Hot water will be produced at next scheduled
action.
When water heat-up starts, the
icon will
be blinking (1 second interval).
Manual storage (one time water heat-up)(refer to scheme below)
Push and hold the
button
for 5 seconds.
See "Manual storage" on
page 9.
The
icon will start blinking (1 second
interval).
Hot water will be produced.
Reheat (continuous, keeping the minimum water temperature)
Push the
button 1 time.
See "Reheat" on page 9.
Hot water will be produced if the domestic hot
water tank temperature is below the selected
value.
Water will be heated up until the selected
value is reached.
Push and hold the
button for
5 seconds
Display:
icon starts blinking Display: "
"
Your water will be heated till
storage set point (one time action)
The domestic hot water tank is not
installed
For further details and advised
settings, see "4.6. Domestic
water heating operation (
)" on
page 8
NOTE
It is advised to use the remote controller, which
includes room thermostat function, delivered with the
unit.
This will prevent excessive space heating and will stop
the outdoor and indoor unit when the room
temperature is above the thermostat set point. Based
on the request from the user there is an immediate
feedback to the compressor control which optimizes
the performance.
Refer to the typical application examples in the indoor
installation manual for more details.
■
Never let the remote controller get wet. This may
cause an electric shock or fire.
■
Never press the buttons of the remote controller with a
hard, pointed object. This may damage the remote
controller.
■
Never inspect or service the remote controller
yourself, ask a qualified service person to do this.
■
Do not rinse the indoor unit. This may cause electric
shock or fire.
■
Do not climb, sit or stand on top of the unit.
■
Do not place any objects or equipment on the unit top
plate.
NOTE
Remark that pushing the
button has no
influence on the domestic water heating.
Domestic water heating is only switched on or off
by means of the
button and/or disabling the
storage schedule timer.
135 6 238
13
33
24
11
18
20
14
4
7
9
12
10
21
32
25
26
22
19
31
30
29
27
28
21715
16
Содержание
- Daikin altherma indoor unit 1
- Operation manual 1
- Definitions 2
- Operation manual 2
- General information 3
- Introduction 3
- Ntroduction 3
- Quick start up of the unit 3
- Scope of this manual 3
- Space heating operation 3
- Domestic water heating operation 4
- Operation of the unit 4
- Peration 4
- Remote controller buttons and icons 4
- Room temperature control 6
- Setting the clock 6
- Space heating operation 6
- Space heating operation h 6
- Leaving water temperature control 7
- Emergency operation 8
- Leaving water temperature control 8
- Room temperature control 8
- Space cooling operation 8
- Space cooling operation c 8
- Automatic storage 9
- Domestic water heating operation 9
- Domestic water heating operation w 9
- Disinfection operation 10
- Manual storage 10
- Reheat 10
- Defrost operation 11
- Defrost operation d 11
- Other operation modes 11
- Quiet mode operation 11
- Quiet mode operation s 11
- Simultaneous demand of space cooling and domestic water heating 11
- Simultaneous demand of space heating and domestic water heating 11
- Start up operation 11
- Start up operation d 11
- Temperature read out mode 11
- Actions per day of the week can be programmed totalling 28 actions 12
- Advantage of this method is that you can simply switch off the space heating operation by pushing the button without disabling the automatic domestic hot water storage operation e g during summertime when no space heating is required 12
- By default space heating based on temperature set point method 1 is enabled so only temperature shifts are possible no on off instruction 12
- I 0 03 status defines whether on off instruction can be used in the schedule timer for space heating 12
- In schedule timer operation the installation is controlled by the schedule timer the actions programmed in the schedule timer will be executed automatically 12
- In the following tables both methods on how to interpret the schedule timer are shown 12
- Not displayed by pressing the button 12
- Operation example schedule timer based on temperature set points 12
- Refer to programming space heating on page 14 12
- Schedule timer operation 12
- Space heating 12
- The desired method is set through field setting refer to 4 5 field settings on page 19 for a detailed description how to set one or more field settings 12
- The schedule timer is enabled icon displayed or disabled icon 12
- The space heating schedule timer can be programmed in 2 different ways based on the temperature set point both leaving water temperature and room temperature and based on the on off instruction 12
- When setback function is enabled the setback operation will have priority over the scheduled action in the schedule timer 12
- Actions can be programmed these actions are repeated daily 13
- Advantage of this method is that you can simply switch off the space cooling operation by pushing the button without disabling the automatic domestic hot water storage operation 13
- By default space cooling based on temperature set point method 1 is enabled so only temperature shifts are possible no on off instruction 13
- Domestic water heating 13
- Domestic water heating can be done through several standard operation modes 13
- For cooling no setback function is available 13
- I 0 04 status defines whether on off instruction can be used in the schedule timer for space cooling 13
- I automatic storage by field setting once during night and or once during the afternoon the water is heated till storage set point 13
- I based on the on off instruction 13
- I based on the temperature set point leaving water temperature and room temperature 13
- I for energy saving reasons keep hours with low electricity cost tariffs in mind when programming the schedule timer for domestic water heating 13
- I manual storage if due to special circumstances production of hot water till storage set point is needed immediately 1 time this function can be used 13
- I reheat the reheat function can be activated next to or separate from the automatic storage operation if the user wants to keep the domestic hot water tank at the minimum reheat temperature 13
- I remark that only the time when domestic water heating must start and stop can be programmed in the schedule timer when domestic water heating is enabled the water will be heated till storage set point the storage set point is set through field setting 13
- Next to the standard domestic water heating operation modes it is also possible to freely program the domestic water heating operation through the schedule timer refer to programming domestic water heating on page 16 then the mode is switched on or off at a scheduled time 4 actions can be programmed per mode these actions are repeated daily additional schedule of storage on top of the automatic day and night storage functionality 13
- Off on on 13
- Operation example schedule timer based on on off instruction 13
- Refer to programming domestic water heating on page 16 13
- Refer to programming space cooling on page 15 13
- Space cooling 13
- The desired method is set through field setting refer to 4 5 field settings on page 19 for a detailed description how to set one or more field settings 13
- The implementation and meaning of setting 0 04 and schedule settings are the same as for heating operation see operation example schedule timer based on temperature set points on page 11 and operation example schedule timer based on on off instruction on page 12 13
- The space cooling schedule timer can be programmed in 2 different ways 13
- When setback function is enabled the setback operation will have priority over the scheduled action in the schedule timer if on instruction is active if off instruction is active this will have priority over the setback function at any time the off instruction will have the highest priority 13
- Programming and consulting the schedule timer 14
- Quiet mode 14
- Programming space heating 15
- Programming space cooling 16
- Programming domestic water heating 17
- Programming quiet mode 18
- Consulting programmed actions 19
- Operating the optional remote controller 19
- Operating the remote alarm option 19
- Tips and tricks 19
- Field settings 20
- Procedure 20
- Field settings table 21
- Aintenance 23
- Disposal requirements 23
- Important information regarding the refrigerant used 23
- Isposal requirements 23
- Maintenance 23
- Maintenance activities 23
- Roubleshooting 23
- Troubleshooting 23
Похожие устройства
- Daikin EKHVMYD50ABV1 Инструкция по монтажу
- Supra KES-1799 Инструкция по эксплуатации
- Supra KES-1897 Инструкция по эксплуатации
- Daikin EKHVMYD80ABV1 Руководство по монтажу
- Daikin EKHVMYD80ABV1 Инструкция по эксплуатации
- Supra KES-1898 Инструкция по эксплуатации
- Daikin EKHVMYD80ABV1 Инструкция по монтажу
- Supra KES-1899 Инструкция по эксплуатации
- Supra KES-1891 Инструкция по эксплуатации
- Supra KES-2020G Инструкция по эксплуатации
- Supra KES-1893 Инструкция по эксплуатации
- Supra KES-1860G Инструкция по эксплуатации
- Supra KES-1851G Инструкция по эксплуатации
- Supra KES-1596 Инструкция по эксплуатации
- Supra KES-1800 Инструкция по эксплуатации
- Supra KES-1840S Инструкция по эксплуатации
- Supra KES-1841S Инструкция по эксплуатации
- Supra KES-1845S Инструкция по эксплуатации
- Supra KES-1846SW Инструкция по эксплуатации
- Supra KES-1842S Инструкция по эксплуатации