Beko FFSS62000W [15/64] Installation and connection

Содержание

Cooker stability chain for cookers not designed with bracket engagement slot bath or shower The cooker must not be installed in a Room ventilation Do not install this appliance in a room below ground level unless it is open to ground level on at least one side All rooms require an openable window or equivalent and some rooms will require a permanent vent as well The air for combustion is taken from the room air and the exhaust gases are emitted directly into the room Good room ventilation is essential for safe operation of your appliance If the room where the appliance is installed does not have a door or a window that opens directly to the outer environment there must definitely be a fixed ventilation opening in the room The fixed ventilation must be nonadjustable and non closable On the doors or windows that open directly to the outer environment there must be a ventilation opening with the dimensions specified based on the total gas power of the appliance as shown below You can find the gas power and ventilation opening match up in the table below min Ventilation Total gas consumption kW opening cm2 0 2 100 2 3 3 4 120 175 4 6 6 8 400 300 8 10 500 10 11 5 11 5 13 600 700 13 15 5 800 15 5 17 900 17 19 1000 19 24 1250 If the doors or windows that open directly to the outer environment do not have openings corresponding to the ventilation opening specified according to the total gas power of the product there must definitely be a fixed ventilation opening in the room The fixed ventilation opening should also be in compliance with the values in the gas power ventilation opening table There should be a minimum clearance of 10 mm on the bottom edge of the door that opens to the inner environment in the room where the product is installed You must make sure that items such as carpets floorings etc do not cover this clearance when the door is closed The cooker may be located in a kitchen kitchen diner or a bed sitting room but not in a room containing a bed sitting room of less than 20m3 Installation and connection Product can only be installed and connected in accordance with the statutory installation rules B o not install the product next to refrigerators freezers The heat emitted by the product ill increase the energy consumption of Doling appliances Carry the product with at least two persons Product must be placed directly on the floor It must not be placed onto a base or a pedestal DO not use the door and or handle to carry or move the product The door handle or hinges get damaged E Electrical connection Connect the product to a grounded outlet line protected by a fuse of suitable capacity as stated in the Technical specifications table Have the grounding installation made by a qualified electrician while using the product with or without a transformer Our company shall not be liable for any damages that will arise due to using the product without a grounding installation in accordance with the local regulations DANGER The product must be connected to the mains supply only by an authorised and qualified person The product s warranty period starts only after correct installation Manufacturer shall not be held responsible for damages arising from procedures carried out by unauthorised persons B DANGER The power cable must not be clamped bent or trapped or come into contact with hot parts of the product A damaged power cable must be replaced by a qualified electrician Otherwise there is risk of electric shock short circuit or fire The mains supply data must correspond to the data specified on the type label of the product The rating plate is either seen when the door or the lower cover is opened or it is located at the rear wall of the unit depending on the unit type Power cable of your product must comply with the values in Technical specifications table 15 EN

Скачать