Beko HII64500FHTX [10/80] Installation and connection

Содержание

Installation and connection Connecting the power cable_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ The product must be installed in accordance with all local gas and electrical regulations P J While performing the wiring you must apply I I Jwith the national local electrical regulations Pk must use the appropriate socket outlet line and plug for oven In case of the product s power limits are out of current carrying capability of plug and socket outlet line the product must be connected through fixed electrical installation directly without using plug and socket outlet line not install the hob on places with sharp l W ledges or corners BbZ There is the risk of breaking for glass ceramic surface Electrical connection Connect the product to a grounded outlet line protected by a miniature circuit braker of suitable capacity as stated in the Technical specifications table Have the grounding installation made by a qualified electrician while using the product with or without a transformer Our company shall not be liable for any damages that will arise due to using the product without a grounding installation in accordance with the local regulations DANGER The product must be connected to the mains supply only by an authorised and qualified person The product s warranty period starts only after correct installation Manufacturer shall not be held responsible for damages arising from procedures carried out by unauthorised persons 1 If it is not possible to disconnect all poles in the supply power a disconnection unit with at least 3 mm contact clearance fuses line safety switches contactors must be connected and all the poles of this disconnection unit must be adjacent to not above the product in accordance with IEE directives Failure to obey this instruction may cause operational problems and invalidate the product warranty Additional protection by a residual current circuit breaker is recommended If a cable is supplied with the product A DANGER The power cable must not be clamped bent or trapped or come into contact with hot parts of the product A damaged power cable must be replaced by a qualified electrician Otherwise there is risk of electric shock short circuit or fire Connection must comply with national regulations The mains supply data must correspond to the data specified on the type label of the product Type label is at the rear housing of the product Power cable of your product must comply with the values in Technical specifications table DANGER Before starting any work on the electrical installation disconnect the product from the mains supply There is the risk of eletric shock 2NÂC38 4Ï5V 1HAC22Ô 240V 2 For single phase connection connect the wires as identified below Brown Black cable L Phase Blue Grey cable N Neutral Green yellow cable E Ground or Grey Black cable L Phase Blue Brown cable N Neutral Green yellow cable E Ground 3 For double phase connection connect the wires as identified below Brown cable L1 Phase 1 Black cable L2 Phase 2 Blue Grey cable N Neutral 10 EN

Скачать