Daikin FTXS50D2V1L [17/32] Econo operation
![Daikin FTKS50D2V1L [17/32] Econo operation](/views2/1771995/page17/bg11.png)
16
ECONO Operation
ECONO operation is a function which enables efficient operation by lowering the maximum power con-
sumption value.
■ To start ECONO operation
1. Press “ECONO button” .
• “ ” is displayed on the LCD.
■ To cancel ECONO opera-
tion
2. Press “ECONO button” again.
• “ ” disappears from the LCD.
NOTE
• ECONO Operation can only be set when the unit is running. Pressing the operation stop
button causes the settings to be canceled, and the “ ” disappears from the LCD.
• ECONO operation is a function which enables efficient operation by limiting the power
consumption of the outdoor unit (operating frequency).
• ECONO operation functions in AUTO, COOL, DRY, and HEAT modes.
• POWERFUL operation and ECONO operation cannot be used at the same time.
Priority is given to the function of whichever button is pressed last.
• Power consumption may not drop even if ECONO operation is used, when the level of
power consumption is already low.
TEMP
ON/OFF
POWERFUL
MODE
FAN
SWING
QUIET
SENSOR
ECONO
COMFORT
TIMER
ON
CANCEL
OFF
1, 2
01_EN_3P212420-2.fm Page 16 Monday, July 30, 2007 1:59 PM
Содержание
- Daikin room air conditioner 1
- Deutsch 1
- English 1
- Español 1
- Français 1
- Italiano 1
- Operation manual 1
- Türkçe 1
- Ελληνικü 1
- Contents 2
- Operation 2
- Read before operation 2
- Trouble shooting 2
- Caution 3
- Safety precautions 3
- Warning 3
- Consider nuisance to your neighbours from noises 4
- Electrical work 4
- Installation site 4
- System relocation 4
- Indoor unit 5
- Names of parts 5
- Outdoor unit 6
- Arc433b50 b4 7
- Remote controller 7
- Attention 8
- Preparation before operation 8
- To set the batteries 8
- Attention 9
- Choose a place from where the sig nals reach the unit 9
- Fix the holder to a wall a pillar or similar location with the screws procured locally 9
- Place the remote controller in the remote controller holder 9
- Preparation before operation 9
- To fix the remote controller holder on the wall 9
- To operate the remote controller 9
- Be careful not to cool heat the room too much keeping the temperature setting at a moderate level helps save energy cover windows with a blind or a curtain blocking sunlight and air from outdoors increases the cooling heating effect clogged air filters cause inefficient operation and waste energy clean them once in about every two weeks 10
- If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker off 10
- Mode fan 10
- Operation outside this humidity or temperature range may cause a safety device to disable the system 10
- Please note 10
- Press clock button 10
- Sensor 10
- The air conditioner always consumes 15 35 watts of electricity even while it is not operating 10
- Tips for saving energy 10
- To set the clock 10
- Turn the breaker on 10
- Use the air conditioner in the following conditions 10
- _en_3p212420 2 fm page 9 monday july 30 2007 1 59 pm 10
- Auto dry cool heat fan operation 11
- Press mode selector button and select a operation mode 11
- Press on off button 11
- Press on off button again 11
- Press temperature adjustment button 11
- To change the temperature setting 11
- To start operation 11
- To stop operation 11
- Press fan setting button 12
- To change the airflow rate setting 12
- Adjusting the airflow direction 13
- Press swing button 13
- To adjust the horizontal blades flaps 13
- To adjust the vertical blades louvers 13
- When the flaps have reached the desired position press swing button once more 13
- Cool dry the flap will go up heat the flap will go down 14
- Notes on comfort airflow operation 14
- Notes on flaps and louvers angles 14
- Press comfort airflow button 14
- Press comfort airflow button again 14
- To cancel comfort airflow operation 14
- To start comfort airflow operation 14
- Powerful operation 15
- To cancel powerful operation 15
- To start powerful operation 15
- Outdoor unit quiet operation 16
- To cancel outdoor unit quiet operation 16
- To start outdoor unit quiet operation 16
- Econo operation 17
- To cancel econo opera tion 17
- To start econo operation 17
- Intelligent eye operation 18
- Press sensor button 18
- Press sensor button again 18
- To cancel the intelligent eye operation 18
- To start intelligent eye operation 18
- Caution 19
- Intelligent eye is useful for energy saving 19
- Intelligent eye operation 19
- Notes on intelligent eye 19
- Timer operation 20
- To cancel the off timer operation 20
- To use off timer operation 20
- Attention 21
- Timer operation 21
- To cancel on timer operation 21
- To combine on timer and off timer 21
- To use on timer operation 21
- Night quiet mode available only for cooling operation 22
- Note for multi system 22
- Outdoor unit quiet operatio 22
- Selecting the operation mode 22
- Note for multi system 23
- Operation mode priority 23
- Priority room setting 23
- Priority when powerful operation is used 23
- Priority when using outdoor unit quiet operation 23
- Attach the front panel 24
- Before cleaning be sure to stop the operation and turn the breaker off 24
- Care and cleaning 24
- Caution 24
- Clean the front panel 24
- Front panel 24
- Indoor unit outdoor unit and remote controller 24
- Open the front panel 24
- Remove the front panel 24
- Wipe them with dry soft cloth 24
- Air filter 25
- Filters 25
- Maintenance 25
- Replacement 25
- Titanium apatite photocatalytic air purifying filte 25
- After operation stops turn off the breaker for the room air conditioner 26
- Before a long idle period 26
- Clean the air filters and set them again 26
- Operate the fan only for several hours on a fine day to dry out the inside 26
- Take out batteries from the remote controller 26
- Case explanation 27
- These cases are not troubles 27
- Trouble shooting 27
- Case check 28
- Check again 28
- Call the service shop immediately 29
- Disposal requirements 29
- Important information regarding the refrigerant used 29
- The power cord is abnormally hot or damaged an abnormal sound is heard during operation the safety breaker a fuse or the earth leakage breaker cuts off the operation frequently a switch or a button often fails to work properly there is a burning smell water leaks from the indoor unit 29
- Turn the breaker off and call the service shop 29
- Warning 29
- We recommend periodical maintenance 29
- A short beep and two consecutive beeps indicate non corresponding codes 30
- Fault diagnosis 30
- In the arc433 series the temperature display sections on the main unit indicate corresponding codes 30
- The code indication changes as shown below and notifies with a long beep 30
- To cancel the code display hold the timer cancel button down for 5 seconds the code display also cancel itself if the button is not pressed for 1 minute 30
Похожие устройства
- Daikin FTXS50D2V1L Инструкция по монтажу
- Daikin FTXS50D2V1L Сервис мануал
- Daikin FTXV25AV1B Инструкция по монтажу
- Daikin FTXV35AV1B Инструкция по монтажу
- Daikin FTXV50AV1B Инструкция по монтажу
- Daikin FTXV60AV1B Инструкция по монтажу
- Daikin FVXM25A2V1B Инструкция по эксплуатации
- Daikin FVXM25A2V1B Инструкция по монтажу
- Daikin FVXM25A2V1B Справочник установщика
- Daikin FVXM35A2V1B Инструкция по эксплуатации
- Daikin FVXM35A2V1B Инструкция по монтажу
- Daikin FVXM35A2V1B Справочник установщика
- Daikin FVXM50A2V1B Инструкция по эксплуатации
- Daikin FVXM50A2V1B Инструкция по монтажу
- Daikin FVXM50A2V1B Справочник установщика
- Daikin FWXV15AVEB Инструкция по монтажу
- Daikin FWXV15AVEB Руководство по установке
- Daikin FWXV15AVEB Приложение к руководству для дополнительного оборудования
- Daikin FWXV15AVEB Инструкция по эксплуатации
- Daikin FWXV20AVEB Инструкция по монтажу