P.I.T. PAC24-C1 [7/25] Troubleshooting

Содержание

Air compressor Technology AIR COMPRESSOR TROUBLESHOOTING Reduced Compressor Performance Causes Actions 1 Air filter is clogged 2 Joints or to air ducts are damaged 1 Clean or replace filter unit 2 Find location of the leak then seal the joint or replace the air duct Air leakage from the receiver to the discharge air duct constant hissing when the compressor Is turned off Causes Actions 1 Air from the receiver enters the discharge air duct due to wear or clogging of the check valve seal 1 Unscrew the hex head of the valve clean the seat and the gasket or replace it Electric motor overheating and compressor stop during operation Causes Actions 1 Insufficient oil level in the compressor crankcase 2 Prolonged compressor operation at maxi mum pressure and air consumption ther mal protection is triggered 3 Low mains voltage 1 Check the quality and level of oil if neces sary add oil 2 Reduce the load on the compressor by reducing air consumption The compressor will start automatically 3 Disconnect all extension cords from the power supply circuit Compressor stops during operation Causes Actions 1 Power supply failure 1 Check the power circuit Compressor turns off and then turns on after a few minutes Causes Actions 1 Thermal protection is triggered due to overheating of the electric motor 1 Clean the air supply hoses Ventilate the room Return the thermal protection relay to working condition Check the level and quality of oil