Daikin RXB25B6V1 [4/40] English
![Daikin RXB25B6V1 [4/40] English](/views2/1772327/page4/bg4.png)
1 English
Safety Precautions
• Read these Safety Precautions carefully to ensure correct installation.
• This manual classifies the precautions into WARNING and CAUTION.
Be sure to follow all the precautions below: they are all important for ensuring safety.
WARNING.........Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
CAUTION......... Failure to follow any of CAUTION may result in grave consequences in some cases.
• The following safety symbols are used throughout this manual:
• After completing installation, test the unit to check for installation errors. Give the user adequate instructions
concerning the use and cleaning of the unit according to the Operation Manual.
• The English text is the original instruction. Other languages are translations of
the original instructions.
Be sure to observe this instruction. Be sure to establish an earth connection. Never attempt.
WARNING
• Installation should be left to the dealer or another professional.
Improper installation may cause water leakage, electrical shock, or fire.
• Install the air conditioner according to the instructions given in this manual.
Incomplete installation may cause water leakage, electrical shock, or fire.
• Be sure to use the supplied or specified installation parts.
Use of other parts may cause the unit to come to lose, water leakage, electrical shock, or fire.
• Install the air conditioner on a solid base that can support the weight of the unit.
An inadequate base or incomplete installation may cause injury in the event the unit falls off the base.
• Electrical work should be carried out in accordance with the installation manual and the national electrical wiring
rules or code of practice.
Insufficient capacity or incomplete electrical work may cause electrical shock or fire.
• Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance.
• For wiring, use a cable length enough to cover the entire distance with no connection.
Do not use an extension cord. Do not put other loads on the power supply, use a dedicated power
circuit.
(Failure to do so may cause abnormal heat, electric shock or fire.)
• Use the specified types of wires for electrical connections between the indoor and outdoor units.
Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal
overheating or fire.
• After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force
on the electrical covers or panels.
Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, or fire.
• If any refrigerant has leaked out during the installation work, ventilate the room.
(The refrigerant produces a toxic gas if exposed to flames.)
• After all installation is complete, check to make sure that no refrigerant is leaking out.
(The refrigerant produces a toxic gas if exposed to flames.)
• When installing or relocating the system, be sure to keep the refrigerant circuit free from substances other than the
specified refrigerant (R410A), such as air.
(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.)
• During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• During installation, attach the refrigerant piping securely before running the compressor.
If the compressor is not attached and the stop valve is open during pump-down, air will be sucked in when the compressor is run, causing
abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone earth.
Incomplete earth may cause electrical shock, or fire. A high surge current from lightning or other sources may cause damage to the
air conditioner.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks, or fire.
CAUTION
• Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage.
If the gas leaks and builds up around the unit, it may catch fire.
• Establish drain piping according to the instructions of this manual.
Inadequate piping may cause flooding.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is tightened too hard, the flare nut may crack after a long time and cause refrigerant leakage.
3P291651-9T.book Page 1 Tuesday, December 9, 2014 2:55 PM
Содержание
- Installation manual 1
- P291651 15v im_draft 1
- R410a split series 1
- Rxbb6 im_digital 1
- Daikin europe n v 3
- En60335 2 4 3
- Low voltage 2006 95 ec electromagnetic compatibility 2004 108 ec machinery 2006 42 ec 3
- P405440 1 3
- P405440 1_doc 3
- Rxb25b6v1 rxb35b6v1 3
- Shigeki morita director ostend 1st of apr 2015 3
- Caution 4
- English 4
- Safety precautions 4
- Warning 4
- Accessories 5
- Accessories supplied with the outdoor unit 5
- Caution 5
- English 2 5
- Precautions for selecting the location 5
- This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial and household use by lay persons sound pressure level is less than 70 db a 5
- Caution 6
- English 6
- Outdoor unit installation drawings 6
- Drain work heat pump models 7
- English 4 7
- Installation guidelines 7
- Installing outdoor unit 7
- Outdoor unit installation 7
- Precautions on installation 7
- Caution 8
- Flaring the pipe end 8
- Outdoor unit installation 8
- Refrigerant piping 8
- Warning 8
- Outdoor unit installation 9
- Purging air and checking gas leakage 9
- Warning 9
- English 10
- Outdoor unit installation 10
- Refilling the refrigerant 10
- Refrigerant piping work 10
- Caution 11
- English 8 11
- How to force cooling operation mode 11
- Pump down operation 11
- English 12
- Warning 12
- Wiring 12
- Caution 13
- English 10 13
- Good wrong 13
- Wiring 13
- English 14
- Test items 14
- Test run and final check 14
- Trial operation and testing 14
- Меры предосторожности 15
- Предупреждение 15
- Русский 1 15
- Предостережение 16
- Принадлежности 16
- Русский 16
- Предостережение 17
- Предостережения относительно выбора места монтажа 17
- Примечание 17
- Русский 3 17
- Монтажный чертеж наружного агрегата 18
- Предостережение 18
- Русский 18
- Дренажные работы модели с тепловым насосом 19
- Меры предосторожности при установке 19
- Монтаж наружного агрегата 19
- Правила монтажа 19
- Русский 5 19
- Монтаж наружного агрегата 20
- Предостережение 20
- Предупреждение 20
- Развальцовка конца трубы 20
- Трубопроводы хладагента 20
- Монтаж наружного агрегата 21
- Предупреждение 21
- Удаление воздуха и проверка герметичности 21
- Дозаправка хладагента 22
- Монтаж наружного агрегата 22
- Русский 8 22
- Монтаж наружного агрегата 23
- Операция откачки 23
- Переключение в режим принудительного охлаждения 23
- Предостережение 23
- Рекомендации по монтажу труб хладагента 23
- Предупреждение 24
- Проводка 24
- Русский 10 24
- Предостережение 25
- Проводка 25
- Русский 25
- Таблица компонентов электрической схемы 25
- Электрическая схема 25
- Опытная эксплуатация и испытания 26
- Позиции проверки 26
- Пробный запуск и окончательная проверка 26
- Русский 12 26
- Güvenlik önlemleri 27
- Türkçe 27
- Aksesuarlar 28
- Bu cihaz mağazalarda hafif endüstriyel tesislerde ve çiftliklerde uzmanlar veya eğitimli kullanıcılar tarafından veya ticari alanlarda ve konutlarda normal kullanıcılar tarafından kullanılmak üzere tasarlanmıştır ses basıncı seviyesi 70 db a nin altındadır 28
- Dış ünite ile verilen aksesuarlar 28
- Dış ünitenin küçük hayvanlar tarafından bir sığınak olarak kullanılmasını önlemek için yeterli önlemleri aldığınızdan emin olun 28
- Klimayı tutuşabilir gaz sızıntısı tehlikesinin mevcut olduğu yerlere monte etmeyin 28
- Konik somunu örneğin bir tork anahtarı kullanılması vb gibi belirtilen bir yöntemle sıkın 28
- Konumun seçilmesine i lişkin önlemler 28
- Tahliye borularını bu kılavuzda verilen talimatlara uygun olarak döşeyin 28
- Türkçe 2 28
- Dış ünite montaj çizimleri 29
- Türkçe 29
- Dış ünite montajı 30
- Dış ünitenin montajı 30
- Montaj kılavuzları 30
- Montajla i lgili önlemler 30
- Tahliye çalışması isı pompası modelleri 30
- Türkçe 4 30
- Boru ucunun konik kesilmesi 31
- Dış ünite montajı 31
- Soğutucu akışkan boruları 31
- Dış ünite montajı 32
- Havanın boşaltılması ve gaz kaçağının kontrolü 32
- Dış ünite montajı 33
- Soğutucu akışkan doldurma 33
- Soğutucu borularının bağlantısı 33
- Türkçe 33
- Boşaltma i şlemi 34
- Türkçe 8 34
- Zorlamalı soğutma çalıştırma modu 34
- Kablo bağlantısı 35
- Türkçe 35
- Doğru yanlış 36
- Kablo bağlantısı 36
- Türkçe 10 36
- Deneme işletmesi ve testler 37
- Test bileşenleri 37
- Test i şletimi ve nihai kontrol 37
- Türkçe 37
- Boş sayfa 39
- Copyright 201 5 daikin 40
- Daikin isitma ve soğutma si stemleri san ti c a ş 40
- P405801 1a 40
Похожие устройства
- Daikin RXB35B5V1 Инструкция по монтажу
- Daikin RXB35B6V19 Инструкция по монтажу
- Daikin RXB35B6V1 Инструкция по монтажу
- Daikin RXB50BV1B Инструкция по эксплуатации
- Daikin RXB50BV1B Инструкция по монтажу
- Daikin RXB60BV1B Инструкция по эксплуатации
- Daikin RXB60BV1B Инструкция по монтажу
- Daikin RXB20C5V1B9 Инструкция по монтажу
- Daikin RXB25C5V1B9 Инструкция по монтажу
- Daikin RXB35C5V1B9 Инструкция по монтажу
- Daikin RXB20C5V1B Инструкция по монтажу
- Daikin RXB25C5V1B Инструкция по монтажу
- Daikin RXB35C5V1B Инструкция по монтажу
- Daikin RXB50CV1B Инструкция по эксплуатации
- Daikin RXB50CV1B Инструкция по монтажу
- Daikin RXB60CV1B Инструкция по эксплуатации
- Daikin RXB60CV1B Инструкция по монтажу
- P.I.T. P31045 Инструкция Пользователя
- P.I.T. PMG150-С Инструкция Пользователя
- P.I.T. PMG200-С1 Инструкция Пользователя