Daikin RXL42J3V1B [10/16] Pump down operation
![Daikin RXL42J3V1B [10/16] Pump down operation](/views2/1772601/page10/bga.png)
8 nEnglish
Pump Down Operation
In order to protect the environment, be sure to pump down when relocating or disposing of the unit.
1) Remove the valve cap from liquid stop valve and gas stop valve.
2) Carry out forced cooling operation.
3) After five to ten minutes, close the liquid stop valve with a hexagonal wrench.
4) After two to three minutes, close the gas stop valve and stop forced cooling operation.
How to force cooling operation mode
n Using the indoor unit operation/stop button
Press the indoor unit operation/stop button for at least five seconds.
(Operation will start.)
• Forced cooling operation will stop automatically after around 15 minutes.
To force a test run to stop, press the indoor unit operation/stop button.
n Using the main unit’s remote controller
1) Press the “operation/stop” button.
(Operation will start.)
2)
Press the temperature
button and the “operation select” button at the same time.
3) Press the “operation select” button twice.
(
will be displayed and the unit will enter test run mode.)
4) Press the “operation select” button to return the operation mode to cooling.
• Test run mode will stop automatically after around 30 minutes. To force a test run to stop, press the operation/stop but-
ton.
CAUTION
1) When pressing the switch, do not touch the terminal block. It has a high voltage, so doing so may cause electric shock.
2) After closing the liquid stop valve, close the gas stop valve within three minutes, then stop the forced operation.
Gas
stop valve
Valve cap
Hexagonal
wrench
Close
Liquid
stop valve
Содержание
- Daikin industries czech republic s r o 2
- En60335 2 4 2
- Low voltage 2006 95 ec machinery 2006 42 ec electromagnetic compatibility 2004 108 ec 2
- P291651 7d_offset book page 1 sunday july 8 2012 3 14 pm 2
- P327445 5a 2
- Rxl42j3v1b 2
- Takayuki fujii managing director 1st of 012 2
- Caution 3
- N english 1 3
- Safety precautions 3
- Warning 3
- Accessories 4
- Accessories supplied with the outdoor unit 4
- Caution 4
- N english 4
- Precautions for selecting the location 4
- Caution 5
- English 5
- N english 3 5
- Outdoor unit installation drawings 5
- Installation guidelines 6
- Installing outdoor unit 6
- N english 6
- Outdoor unit installation 6
- Precautions on installation 6
- Caution 7
- Flaring the pipe end 7
- Outdoor unit installation 7
- Refrigerant piping 7
- Warning 7
- N english 8
- Purging air and checking gas leakage 8
- Warning 8
- Important information regarding the refrigerant used 9
- Outdoor unit installation 9
- Refilling the refrigerant 9
- Refrigerant piping work 9
- Caution 10
- How to force cooling operation mode 10
- N english 10
- Pump down operation 10
- Caution 11
- Facility setting cooling at low outdoor temperature 11
- N english 9 11
- Caution 12
- Good wrong 12
- N english 12
- Warning 12
- Wiring 12
- C74 c75 c94 13
- C95 capacitor 13
- Db1 db2 db3 diode bridge 13
- E1h heater 13
- English 13
- Fu1 fu2 fu3 13
- Fu4 fu5 fuse 13
- Fu6 field fuse 13
- Ipm1 intelligent power module 13
- L live 13
- L1 coil 13
- L1r reactor 13
- M1c compressor motor 13
- M1f fan motor 13
- Mrcw mrm10 13
- Mrm20 mr30 magnetic relay 13
- N english 11 13
- N neutral 13
- Pcb1 printed circuit board 13
- Protective earth 13
- Q1di earth leak detector 13
- Q1l overload protector 13
- Q31 igbt 13
- R1t r3t thermistor 13
- S1t thermostat 13
- S20 s40 s70 13
- S80 s90 13
- Sa1 surge arrester 13
- V1 v3 v4 varistor 13
- Wiring diagram 13
- Wiring diagram parts table 13
- X11a s1 connector 13
- X1m terminal strip 13
- Y1e electronic expansion valve coil 13
- Y1r reversing solenoid valve coil 13
- Z1c z2c z3c 13
- Z4c ferrite core 13
- N english 14
- Test items 14
- Test run and final check 14
- Trial operation and testing 14
Похожие устройства
- Daikin RXS60F2V1B Руководство по монтажу
- Daikin RXS60F3V1B Руководство по монтажу
- Daikin RXS60F4V1B Руководство по монтажу
- Daikin RXS71FAV1B Руководство по монтажу
- Daikin RXS71FV1B Руководство по монтажу
- Daikin RXS71FAV1B9 Руководство по монтажу
- Daikin RXS71FAV1B8 Руководство по монтажу
- Daikin RKS71FAV1B Руководство по монтажу
- Daikin RKS71FV1B Руководство по монтажу
- Daikin RXM42R2V1B Руководство по монтажу
- Daikin RXM50R2V1B Руководство по монтажу
- Daikin RXM60R2V1B Руководство по монтажу
- Daikin RXM71R2V1B Руководство по монтажу
- Daikin RXS50J2V1B Руководство по монтажу
- Daikin RKS50J2V1B Руководство по монтажу
- Daikin RKS60F3V1B Руководство по монтажу
- Daikin RXS50G2V1B Руководство по монтажу
- Daikin RKS50G2V1B Руководство по монтажу
- Daikin RKS60F2V1B Руководство по монтажу
- Daikin RYN50E3V1B Руководство по монтажу