Daikin RXL42J3V1B [4/16] Precautions for selecting the location
![Daikin RXL42J3V1B [4/16] Precautions for selecting the location](/views2/1772601/page4/bg4.png)
2 nEnglish
Accessories
Accessories supplied with the outdoor unit:
Precautions for Selecting the Location
1) Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be amplified.
2) Choose a location where the hot air discharged from the unit or the operation noise will not cause a nuisance to the neighbors of
the user.
3) Avoid places near a bedroom and the like, so that the operation noise will cause no trouble.
4) There must be sufficient spaces for carrying the unit into and out of the site.
5) There must be sufficient space for air passage and no obstructions around the air inlet and the air outlet.
6) The site must be free from the possibility of flammable gas leakage in a nearby place.
7) Install units, power cords and inter-unit cables at least 3 meter away from television and radio sets. This is to prevent interference
to images and sounds. (Noises may be heard even if they are more than 3 meter away depending on radio wave conditions.)
8) In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may shorten the life of the air conditioner.
9) Since drain flows out of the outdoor unit, do not place under the unit anything which must be kept away from moisture.
NOTE
Cannot be installed hanging from ceiling or stacked.
CAUTION
When operating the air conditioner in a low outdoor ambient tempera-
ture, be sure to follow the instructions described below.
1) To prevent exposure to wind, install the outdoor unit with its suction
side facing the wall.
2) Never install the outdoor unit at a site where the suction side may
be exposed directly to wind.
3) To prevent exposure to wind, it is recommended to install a baffle
plate on the air discharge side of the outdoor unit.
4) In heavy snowfall areas, select an installation site where the snow will not affect the unit.
•
Make sure to provide for adequate measures in order to prevent that the outdoor unit be used as a shelter by small
animals.
Small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct the customer to keep the area around the unit clean.
•
This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial
and household use by lay persons.
•
Sound pressure level is less than 70 dB(A).
(A) Installation Manual
1
(B) Refrigerant charge label
1
(C) Multilingual fluorinated greenhouse gases label
1
Construct a large canopy.
Construct a pedestal.
Install the unit high enough off the
ground to prevent burying in snow.
Содержание
- Daikin industries czech republic s r o 2
- En60335 2 4 2
- Low voltage 2006 95 ec machinery 2006 42 ec electromagnetic compatibility 2004 108 ec 2
- P291651 7d_offset book page 1 sunday july 8 2012 3 14 pm 2
- P327445 5a 2
- Rxl42j3v1b 2
- Takayuki fujii managing director 1st of 012 2
- Caution 3
- N english 1 3
- Safety precautions 3
- Warning 3
- Accessories 4
- Accessories supplied with the outdoor unit 4
- Caution 4
- N english 4
- Precautions for selecting the location 4
- Caution 5
- English 5
- N english 3 5
- Outdoor unit installation drawings 5
- Installation guidelines 6
- Installing outdoor unit 6
- N english 6
- Outdoor unit installation 6
- Precautions on installation 6
- Caution 7
- Flaring the pipe end 7
- Outdoor unit installation 7
- Refrigerant piping 7
- Warning 7
- N english 8
- Purging air and checking gas leakage 8
- Warning 8
- Important information regarding the refrigerant used 9
- Outdoor unit installation 9
- Refilling the refrigerant 9
- Refrigerant piping work 9
- Caution 10
- How to force cooling operation mode 10
- N english 10
- Pump down operation 10
- Caution 11
- Facility setting cooling at low outdoor temperature 11
- N english 9 11
- Caution 12
- Good wrong 12
- N english 12
- Warning 12
- Wiring 12
- C74 c75 c94 13
- C95 capacitor 13
- Db1 db2 db3 diode bridge 13
- E1h heater 13
- English 13
- Fu1 fu2 fu3 13
- Fu4 fu5 fuse 13
- Fu6 field fuse 13
- Ipm1 intelligent power module 13
- L live 13
- L1 coil 13
- L1r reactor 13
- M1c compressor motor 13
- M1f fan motor 13
- Mrcw mrm10 13
- Mrm20 mr30 magnetic relay 13
- N english 11 13
- N neutral 13
- Pcb1 printed circuit board 13
- Protective earth 13
- Q1di earth leak detector 13
- Q1l overload protector 13
- Q31 igbt 13
- R1t r3t thermistor 13
- S1t thermostat 13
- S20 s40 s70 13
- S80 s90 13
- Sa1 surge arrester 13
- V1 v3 v4 varistor 13
- Wiring diagram 13
- Wiring diagram parts table 13
- X11a s1 connector 13
- X1m terminal strip 13
- Y1e electronic expansion valve coil 13
- Y1r reversing solenoid valve coil 13
- Z1c z2c z3c 13
- Z4c ferrite core 13
- N english 14
- Test items 14
- Test run and final check 14
- Trial operation and testing 14
Похожие устройства
- Daikin RXS60F2V1B Руководство по монтажу
- Daikin RXS60F3V1B Руководство по монтажу
- Daikin RXS60F4V1B Руководство по монтажу
- Daikin RXS71FAV1B Руководство по монтажу
- Daikin RXS71FV1B Руководство по монтажу
- Daikin RXS71FAV1B9 Руководство по монтажу
- Daikin RXS71FAV1B8 Руководство по монтажу
- Daikin RKS71FAV1B Руководство по монтажу
- Daikin RKS71FV1B Руководство по монтажу
- Daikin RXM42R2V1B Руководство по монтажу
- Daikin RXM50R2V1B Руководство по монтажу
- Daikin RXM60R2V1B Руководство по монтажу
- Daikin RXM71R2V1B Руководство по монтажу
- Daikin RXS50J2V1B Руководство по монтажу
- Daikin RKS50J2V1B Руководство по монтажу
- Daikin RKS60F3V1B Руководство по монтажу
- Daikin RXS50G2V1B Руководство по монтажу
- Daikin RKS50G2V1B Руководство по монтажу
- Daikin RKS60F2V1B Руководство по монтажу
- Daikin RYN50E3V1B Руководство по монтажу