Daikin FTKS50BVMA [7/84] When absence shift down automatically makes energy saving intelligently

Daikin FTKS50BVMA [7/84] When absence shift down automatically makes energy saving intelligently
Features EDAU04-309A
6 Room Air Conditioners B-Series
03RAGH-14
Cooling
= Automatic shift up when sensing no human, intelligently saving energy =
time
Temperature
•2°CShift up
Minimum frequency
(34Hz)
20min
Absence
Normal
operation
Energy
Saving
operation
Normal
operation
Back to
normal
operation
when
presence
detected
Normal
operation
Energy saving
operation
activated
Power consumption
Saving
20%!
Intelligent Eye
03RAGH-15
Heating
= When absence shift down automatically makes energy saving intelligently =
Normal
operation
Energy
Saving
operation
Normal
operation
Returns to
normal operation
upon sensing
a sign of human
Normal
operation
Power consumption
Saving
30%!
time
Temperature
•2°CShift down
Minimum frequency
(34Hz)
20min
Absence
Energy saving
operation
activated
Intelligent Eye
03RAGH-16
<Note>
If the unit operates in “Quiet” or
“Ultra low” mode with small air
flow, operating noise is reduced
but cooling / heating capacity is
reduced too.
Indoor unit’s fan
H
M
L
SL
Quiet “ON”
Auto Quiet Ultra low HighLow
Air flow setting button
When air flow is set to “Quiet” through a remote controller,
the operation sound of the indoor unit is reduced by 3dB.
This is a convenient function while studying or sleeping.