Daikin ATX20JV1B [134/156] Removal of outdoor fan fan motor

Daikin ATX20JV1B [134/156] Removal of outdoor fan fan motor
Outdoor Unit SiBE041010
124 Removal Procedure
2.2 Removal of Outdoor Fan / Fan Motor
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Remove the outdoor fan. Preparation
Remove the panels
according to the “Removal of
Panels”.
1
Disconnect the
connector for the fan
motor [S70].
2
Release the fan motor
lead wire from the
hooks.
The screw has reverse
winding.
Align mark of the outdoor
fan with D-cut section of the
motor shaft when mounting.
Spanner size: 10 mm
3
Release the washer-
fitted nut (M6) of the
outdoor fan with a
spanner.
4
Remove the outdoor
fan.
2. Remove the fan motor.
Put the lead wire through the
back of the motor when
reassembling. (so as not to
be entangled with the
outdoor fan)
1
Remove the screw to
remove the fan motor
fixing frame.
2
Release the fan motor
lead wire from the
hooks.
3
Remove the 3 screws
to remove the fan
motor.
(R7377)
[S70]
F
an motor
l
ea
d
w
i
re
Shaft
D-cut
Mark
Washer-fitted nut
(R12005)
Outdoor
fan
(R11957)
Fan motor fixing frame
(R7381)
Fan motor
(R11958)
(R3249)
Lead wire Outdoor fan

Содержание

Похожие устройства