Daikin RKS50FVMA [181/244] Removal of the pcb

Daikin RKS50FVM [181/244] Removal of the pcb
Outdoor Unit Si04-703A
170 Removal Procedure
2.1.4 Removal of the PCB
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
Remove the electrical box.
1. Remove the
PCB
.
1
Disconnect the
connectors for the
control PCB (S52,
S102).
2
Undo the 4 clamps by
pliers.
3
Loosen the fixing screw
of the cable way board
and disconnect the
earth wire.

Содержание