Microlife BP 2BHO [10/50] Eel 150
![Microlife BP 2BHO [10/50] Eel 150](/views2/1078046/page10/bga.png)
Содержание
Похожие устройства
- Microlife BP 3AS1-2 Инструкция по эксплуатации
- Samsung UE55 ES6557U Инструкция по эксплуатации
- Microlife BP 3BT0-H Инструкция по эксплуатации
- Philips 55 PFL7007T/12 Инструкция по эксплуатации
- Samsung PS64 E8007GU Инструкция по эксплуатации
- Microlife BP 2BI0 Инструкция по эксплуатации
- Hyundai H-LCDVD908T Silver Инструкция по эксплуатации
- Microlife BP A80 Инструкция по эксплуатации
- Samsung YP-U7AS 4Gb Silver Инструкция по эксплуатации
- Microlife BP A50 Инструкция по эксплуатации
- Microlife BP 3BEO-4 Инструкция по эксплуатации
- Samsung YP-Z3AW 4Gb White Инструкция по эксплуатации
- Erisson CVC-816 Инструкция по эксплуатации
- Microlife BP 3AX1 Инструкция по эксплуатации
- Sony NWZ-E573 4Gb Black Инструкция по эксплуатации
- Microlife BP W100 Инструкция по эксплуатации
- Erisson CVA-919 Инструкция по эксплуатации
- Sony NWZ-E573 4Gb White Инструкция по эксплуатации
- Microlife AG1-10 Инструкция по эксплуатации
- Erisson CVA-918 Инструкция по эксплуатации
f Remain seated quietly for 2 minutes before you begin the measurement Comment If it is not possible to fit the cuff to the left arm it can also be placed on the right one However all measurements should be made using the same arm 5 4 Setting the inflation pressure Program the inflation pressure to be approximately 40 mmHg higher than your estimated systolic blood pressure You can choose between 8 initial values 140 160 180 200 220 240 260 and 280 mmHg If you do not know your systolic blood pressure select a value between 160 and 200 The instrument is pre set to 140 mmHg If this initial value is sufficient for you omit the following step and start immediately with the measurement Set the initial pressure as follows a Switch on the instrument by pressing the O l button This picture appears on the LCD display It remains there as long as you hold the button pressed down b After the button is released the display flashes as shown and the instrument beeps This indicates that the instrument is automatically adjusting itself to the pressure of the surroundings SYS mmHg____________________ IXAmmHg c After this equalization is completed zero is displayed O Finally a beep is emitted to indicate that the instru ment is ready to take measurements PULS nri d On pressing the SET button the instrument displays SYS mmHg____________________ DfAmmHg the pre set initial pressure for approx 3 seconds e In order to set the initial pressure individually press the SET button briefly for each level until the required 5EL IHO PULSBmr initial pressure is reached Each button press raises the initial pressure by 20 mmHg After reaching 280 mmHg the display starts again at 120 mmHg f After the SET button has been released the instru SYS mmHg____________________ O A mmHg EEL 150 PtAS mn ment is set to the displayed value and the setting up procedure is complete As long as the batteries are not removed the value is stored in the instrument even after it has been switched off SYSm M g______________________ DlA irHg 5EL 180 Comment If the initial pressure selected was too low it will be corrected automatically during the measurement by additional inflation This results in a slightly longer measuring procedure which the patient may find uncomfortable The result of the measurement is normally not affected
Ответы 1
На какой срок работы,расчитан прибор? У меня работает с 2002г где можно сделать проверку или покупать новый? г Березники Пермский край.