Daikin FT18JV1B [14/20] Care and cleaning
![Daikin FT18JV1B [14/20] Care and cleaning](/views2/1781350/page14/bge.png)
13
Fit the key
into the slot.
Slide up the knob.
Care and Cleaning
CAUTION
Clean the front grille.
●
You may wipe it with a soft cloth soaked in water.
●
Only neutral detergent may be used.
●
You may wash the grille with water. After washing,
dry it with cloth, then dry it up in the shade.
Remove the front grille.
●
Supporting the front grille with one hand, release
the lock by sliding down the knob with the other
hand.
●
To remove the front grille, pull it toward yourself
with both hands.
Cleaning the front grille
You may remove the front grille for cleaning.
●
When removing or attaching the front grille, use a
robust and stable stool and watch your steps carefully.
●
When removing or attaching the front grille, support
the grille securely with hand to prevent it from falling.
●
For cleaning, do not use water hotter than 40°C, benzine,
gasoline, thinner, nor other volatile oils, polishing
compound, scrubbing brushes nor othe hard stuff.
●
After cleaning, make sure that the front grille is securely
fixed.
1
3
2
4
Attach the front grille.
●
Set the 3 keys of the front grille into the slots
and push them in all the way.
●
Supporting the front grille with one hand, fit the
lock by sliding up the knob with the other hand.
●
Close the front grille slowly in this state. (Push
the grille at the 3 points, two at both sides and
in the middle.)
Open the front grille.
● Hold the grille by the tabs on the two sides
and lift it until it stops with a click.
Before a long idle period
1
2
Press
MODE
and select “ ”.
Press
ON/OFF
.
1 Operate the fan alone for several
hours on a fine day to dry out the
inside.
<FT>
2 Clean the air filters and set them
again.
3 Take out batteries from the remote
controller.
4 Turn OFF the breaker for the room air
conditioner.
<FTY>
1
2
Press
MODE
and select “ ”.
Press
TEMP
and set the
temperature to 32°C
3
Press
ON/OFF
.
• Perform this operation when the room
temperature is under 28°C.
Check that the base, stand and other
fittings of the outdoor unit are not
decayed or corroded.
Check that nothing blocks the air
inlets and the outlets of the indoor
unit and the outdoor unit.
Check that the earth wire is not
disconnected or broken.
Check that the drain comes smoothly
out of the drain hose during COOL or
DRY operation.
● If no drain water is seen, water may be
leaking from the indoor unit. Stop
operation and consult the service shop
if this is the case.
Check
Содержание
- Daikin room air conditioner 1
- Ft18jv1b fty18jv1b 1
- Ft25jv1b fty22jv1b 1
- Ft35jv1b fty35jv1b 1
- Operation manual 1
- Contents 2
- Operation 2
- Read before operation 2
- Trouble shooting 2
- Caution 3
- Safety precautions 3
- Warning 3
- Caution 4
- Installation 4
- Warning 4
- Consider nuisance to your neighbours from noises 5
- Electrical work 5
- Installation site 5
- System relocation 5
- Air purifying filters are attached to the inside of the air filters 6
- Caution 6
- Indoor unit 6
- Names of parts 6
- Receiver explanation 6
- See page 10 6
- See page 11 see page 11 6
- The louvre is inside of the air outlet see page 10 6
- Names of parts 7
- Outdoor unit 7
- Remote controller 7
- Attention 8
- Preparation before operation 8
- Remote controller 8
- Indoor unit 9
- Preparation before operation 9
- Auto dry cool heat fan operation 10
- G at smaller air flow rates the cooling effect is also smaller 10
- Iiiii to change the air flow direction 10
- Iiiii to stop 10
- Adjusting the air flow direction 11
- Adjusting the horizontal blade flap 11
- Adjusting the vertical blade louvre 11
- Attention 11
- Powerful operation 11
- Attention 12
- Off timer operation 12
- On timer operation 12
- Timer operation 12
- Care and cleaning 13
- Caution 13
- Cleaning the air filters 13
- Before a long idle period 14
- Care and cleaning 14
- Caution 14
- Cleaning the front grille 14
- Explanation 15
- G gg gg these cases are not troubles the following cases are not air conditioner troubles but have some reasons you may just continue using it 15
- Trouble shooting 15
- G gg gg check again please check again before calling a repair person 16
- Trouble shooting 16
- Trouble shooting 17
- Fault diagnosis by remote controller 18
- G gg gg fault diagnosis 18
- Trouble shooting 18
- P062628 1l m00b035b 20
Похожие устройства
- Daikin FT18JV1B Инструкция по эксплуатации
- Daikin FT18JV1B Инструкция по монтажу
- Daikin FT25JV1B Инструкция по эксплуатации
- Daikin FT25JV1B Руководство по эксплуатации
- Daikin FT25JV1B Инструкция по монтажу
- Daikin FT25JV1B Технические данные
- Daikin FT35JV1B Инструкция по эксплуатации
- Daikin FT35JV1B Руководство по эксплуатации
- Daikin FT35JV1B Инструкция по монтажу
- Daikin FT35JV1B Технические данные
- Kenwood TK-3206 Инструкция по эксплуатации
- Kenwood TK-3178 Инструкция по эксплуатации
- Daikin FTY18JV1B Инструкция по эксплуатации
- Daikin FTY18JV1B Руководство по эксплуатации
- Daikin FTY18JV1B Инструкция по монтажу
- Daikin FTY22JV1B Инструкция по монтажу
- Daikin FTY22JV1B Инструкция по эксплуатации
- Daikin FTY22JV1B Руководство по эксплуатации
- Daikin FTY22JV1B Технические данные
- Daikin FTY35JV1B Инструкция по монтажу
Скачать
Случайные обсуждения