Daikin FT18JV1B [18/20] Fault diagnosis by remote controller
![Daikin FT18JV1B [18/20] Fault diagnosis by remote controller](/views2/1781350/page18/bg12.png)
17
FAULT DIAGNOSIS BY REMOTE CONTROLLER
IN THE EVENT OF AN ABNORMALITY, THE RELEVANT ABNORMALITY CODE APPEARS FLASHING
IN THE REMOTE CONTROLLER'S TEMPERATURE DISPLAY.
Trouble Shooting
●●
●●
● Fault diagnosis
MEANING
NORMAL
REFRIGEMENT SHORTAGE
POWER FACTOR MODULE ABNORMALITY
INCORRECT INTERUNIT WIRING(INTERUNIT)
INCORRECT INTERUNIT WIRING
(INDOOR UNIT-REMOTE CONTROLLER)
FREEZE-UP PROTECTOR "OR STOPPED
BY HIGH PRESSURE CONTROL"
FAN MOTOR FAULT
FAULTY HEAT EXCHANGER SENSOR
FAULTY SUCTION AIR TEMPERATURE SENSOR
CODE
00
U0
U2
U4
U5
A5
A6
C4 OR C5
C9
SYSTEM
INDOOR
UNIT
MEANING
INTERNAL THERMOSTAT WORKED OR
HIGH DISCHARGE PIPE TEMPERATURE
FAULTY COMPRESSOR START
CT ABNORMALITY
FAULTY SUCTION AIR
TEMPERATURE SENSOR
FAULTY DISCHARGE PIPE
TEMPERATURE SENSOR
FAULTY HEAT EXCHANGER SENSOR
FAULTY GAS PIPE TEMPERATURE SENSOR
HIGH TEMPERERATURE AT
INVERTER CIRCUIT HEATSINK
FAULTY INVERTER CIRCUIT HEATSINK
TEMPERATURE SENSOR
CODE
E5
E6
H8
H9
J3
J6
J9
L4
P4
OUTDOOR
UNIT
Содержание
- Daikin room air conditioner 1
- Ft18jv1b fty18jv1b 1
- Ft25jv1b fty22jv1b 1
- Ft35jv1b fty35jv1b 1
- Operation manual 1
- Contents 2
- Operation 2
- Read before operation 2
- Trouble shooting 2
- Caution 3
- Safety precautions 3
- Warning 3
- Caution 4
- Installation 4
- Warning 4
- Consider nuisance to your neighbours from noises 5
- Electrical work 5
- Installation site 5
- System relocation 5
- Air purifying filters are attached to the inside of the air filters 6
- Caution 6
- Indoor unit 6
- Names of parts 6
- Receiver explanation 6
- See page 10 6
- See page 11 see page 11 6
- The louvre is inside of the air outlet see page 10 6
- Names of parts 7
- Outdoor unit 7
- Remote controller 7
- Attention 8
- Preparation before operation 8
- Remote controller 8
- Indoor unit 9
- Preparation before operation 9
- Auto dry cool heat fan operation 10
- G at smaller air flow rates the cooling effect is also smaller 10
- Iiiii to change the air flow direction 10
- Iiiii to stop 10
- Adjusting the air flow direction 11
- Adjusting the horizontal blade flap 11
- Adjusting the vertical blade louvre 11
- Attention 11
- Powerful operation 11
- Attention 12
- Off timer operation 12
- On timer operation 12
- Timer operation 12
- Care and cleaning 13
- Caution 13
- Cleaning the air filters 13
- Before a long idle period 14
- Care and cleaning 14
- Caution 14
- Cleaning the front grille 14
- Explanation 15
- G gg gg these cases are not troubles the following cases are not air conditioner troubles but have some reasons you may just continue using it 15
- Trouble shooting 15
- G gg gg check again please check again before calling a repair person 16
- Trouble shooting 16
- Trouble shooting 17
- Fault diagnosis by remote controller 18
- G gg gg fault diagnosis 18
- Trouble shooting 18
- P062628 1l m00b035b 20
Похожие устройства
- Daikin FT18JV1B Инструкция по эксплуатации
- Daikin FT18JV1B Инструкция по монтажу
- Daikin FT25JV1B Инструкция по эксплуатации
- Daikin FT25JV1B Руководство по эксплуатации
- Daikin FT25JV1B Инструкция по монтажу
- Daikin FT25JV1B Технические данные
- Daikin FT35JV1B Инструкция по эксплуатации
- Daikin FT35JV1B Руководство по эксплуатации
- Daikin FT35JV1B Инструкция по монтажу
- Daikin FT35JV1B Технические данные
- Kenwood TK-3206 Инструкция по эксплуатации
- Kenwood TK-3178 Инструкция по эксплуатации
- Daikin FTY18JV1B Инструкция по эксплуатации
- Daikin FTY18JV1B Руководство по эксплуатации
- Daikin FTY18JV1B Инструкция по монтажу
- Daikin FTY22JV1B Инструкция по монтажу
- Daikin FTY22JV1B Инструкция по эксплуатации
- Daikin FTY22JV1B Руководство по эксплуатации
- Daikin FTY22JV1B Технические данные
- Daikin FTY35JV1B Инструкция по монтажу
Скачать
Случайные обсуждения