Tanita BD-815 [3/15] Applications
![Tanita BD-815 [3/15] Applications](/views2/1078153/page3/bg3.png)
GB GB
54
Safety Notes
Caution Symbols
Thank you for purchasing this precision crafted Tanita product. For optimum per-
formance and safety, please familiarize yourself with the Caution Symbols below.
These symbols are designed to alert the user to potential hazards when using this
equipment. Ignoring these Caution Symbols may result in serious
injury, or damage
to the product.
Please be sure to review before proceeding with the INSTRUCTI
ON MANUAL.
• Inserting and Removing the AC adapter
To reduce the risk of electric shock or product damage, never insert or
remove the AC adapter with wet hands.
• D
o not under any circumstances dismantle or alter the device, as this
could result in electric shock or injury as well as adversely affect the preci-
sion of measurements.
• To prevent fire hazard
U
se only a correctly wired (230V AC) outlet, and do not use a multiple
outlet extension cable.
• Ensure the baby is lying down in the basket with minimal movement, as
any resultant fall or slip may cause serious i
njury.
• T
he baby basket is not designed to accommodate individuals weighing
more than 15kg.
• A
s a safety precaution, infants must not be left unattended on the baby basket.
This symbol indicates the possibility of serious
injury if the product is mishandled or instruc-
tions are ignored.
This symbol indicates the possibility of physi-
cal injury or equipment damage if instructions
are ignored.
T
his symbol indicates general precautions that
should be taken when using this product.
Warning
Caution
Warn
ing
•To prevent the spread of infections,
Always clean the weighing platform after use.
Sterilize the platform with an appropriate alcohol-based cleaning fluid before each use.
•Installation of the equipment
Ensure the weighing platform is placed on a level and stable surface. If the equipment is
used when unstable, for example if not all feet are on a level surface,then there is a risk
that scale will tip over and it will be impossible to obtain an accurate measurement.
•Measurement
Always take the utmost care when placing a baby in the Baby Basket. Ensure that there
is no risk of the equipment tipping over.
T
o move the scale, hold it firmily by the main body.
•AC adapter
O
nly use the adapter supplied with this equipment (MODEL: A30930G). Other
adapters may cause malfunctions.
The circuit board incorporates a fuse (100mA, 125V)
for electronic equipment.
If devices other than the original AC adapter are used, or a
large electrical current is applied, the fuse will be blown for safety purposes. As the fuse
f
orms a fixed part of the unit and cannot be easily disassembled, please consult your
nearest Tanita sales office or agent if the fuse needs to be replaced.
•Battery
W
hen changing batteries, ensure that the new batteries are inserted wi
th the correct
polarity +and -.
If the polarity is incorrect, then the batteries may leak and damage the equipment.
•How to handle the equipment when moving it
When carrying the equipment, please do not lift it up by the Baby Basket
Please move the equipment by holding the main body firmly.
•
To avoid any risk of injury or malfunction, keep your fingers, and other objects away
from the space between the inner-plate and the scale.
Caution
This is a precision manufactured and accurately calibrated product. Please
observe the following instructions.
• Never disassemble or adjust the equipment, as this may cause malfunctions. The equip-
ment should only be inspected in accordance with the regulations in each country.
• When not in use for a long time, unplug the AC Adapter from the wall socket.
• When not in use for a long time, remove the batteries before storing the equipment.
• Do not wipe the equipment with corrosive chemicals (benzine, cleaner, etc.). Please use
a neutral detergent to clean the equipment.
• Avoid subjecting the equipment to excessive shocks or vibrations.
•
If an unauthorised person attempts to disassemble or repair any part of the unit, the
warranty will become invalid. If the unit malfunctions, please consult your nearest
Tanita sales office or agent.
• Do not wash any part of the scale other than the basket with water.
• When disposing of this unit ,please do so in accordance with the disposal standard of
industrial waste in each country.
Maintenance
Applications
1.This equipment has been calibrated as a precision instrument and can be used to
certify babies’ weights and/or to certify business transactions.
2.It can also be used to obtain reference data during medical examinations, such as
periodic checkups, and to supervise babies’growth
.
BD815MA_GB 07.11.20, 11:34 AM4-5
Содержание
- Bd 815ma 1
- Bd815ma_gb 07 1 0 11 33 am 1 1
- Instruction manual 1
- Professional baby scale 1
- Application 2
- Baby basket attachment remova 2
- Before use 2
- Caution symbol 2
- Contents 2
- How to set up correctl 2
- How to use 2
- How to use the scal 2
- Memory function for measured value 2
- Names and functions of display panel and operation key 2
- Output data forma 2
- Part names accessorie 2
- Power suppl 2
- Safety note 2
- Specification 2
- Troubleshootin 2
- Various setting method 2
- When necessary 2
- Applications 3
- Bd815ma_gb 07 1 0 11 34 am 4 5 3
- Caution 3
- Maintenance 3
- Safety notes 3
- Warning 3
- Continued 4
- Explanation of terminology 4
- Instructions for measurement 4
- Safety notes 4
- A attachment 5
- B removal 5
- Baby basket attachment removal 5
- Caution 5
- Bd815ma_gb 07 1 0 11 35 am 10 11 6
- Confirmation of accessories 6
- Front back 6
- Part names accessories 6
- Bd815ma_gb 07 1 0 11 35 am 12 13 7
- Display panel 7
- Display panel operation keys 7
- Names and functions of display panel and operation keys 7
- Operation keys 7
- Bd815ma_gb 07 1 0 11 35 am 14 15 8
- Caution 8
- How to set up correctly 8
- Level gauge check 8
- Power supply 8
- Using batteries 8
- Using the ac adapter 8
- How to use the scale 9
- Measurement instructions 9
- Tare weighing function 9
- When tare is not specified 9
- Canceling the tare function 10
- How to use the scale continued 10
- Display weight gain 11
- G is displayed 11
- Memory cancellation 11
- Memory function 11
- Memory function for measured values 11
- Memory value recall method 11
- Place baby on the baby bas ket for a second time 11
- Press the key 11
- Press the key while 11
- Auto power off time 12
- Display hold time 12
- Flashing 12
- Off time press again 12
- Press key 12
- Press key while the screen is 12
- To complete the setting press 12
- To complete to set the auto power 12
- Various setting methods 12
- A when the display is held 13
- B when the weight gain key is pressed 13
- Bd815ma_gb 07 1 0 11 37 am 24 25 13
- C when the recall key is pressed 13
- Connection example 13
- Explanation for rs 232c compliant output 13
- Output data format 13
- Signal line name and connection method 13
- Specifications 13
- Transmission data 13
- Bd815ma_gb 07 1 0 11 37 am 26 27 14
- Check points problem 14
- Specifications 14
- Troubleshooting 14
Похожие устройства
- Fagor 2V-32TS Инструкция по эксплуатации
- Bimatek JM400 Black Инструкция по эксплуатации
- Fagor 2V-33TS Инструкция по эксплуатации
- Tanita KP-601 Инструкция по эксплуатации
- Delonghi EOB2071 Инструкция по эксплуатации
- Tanita KP-400 M Инструкция по эксплуатации
- Fagor 2VFT-211AS Инструкция по эксплуатации
- Philips HP8602/00 Инструкция по эксплуатации
- Fagor IFT-4R Инструкция по эксплуатации
- Tanita Model 1579 Инструкция по эксплуатации
- Babyliss C319E Инструкция по эксплуатации
- Fagor 3FH-4GLSTXNAT Инструкция по эксплуатации
- Tanita 1479Z Инструкция по эксплуатации
- Babyliss C338E Инструкция по эксплуатации
- Fagor 6FI-4GLSX Инструкция по эксплуатации
- Tanita 1479V Инструкция по эксплуатации
- Philips HP8618/00 Инструкция по эксплуатации
- Fagor FFK6845 Инструкция по эксплуатации
- Tanita 1475T Инструкция по эксплуатации
- Bosch DWW063461 Инструкция по эксплуатации