Tanita BD-815 [9/15] How to use the scale
![Tanita BD-815 [9/15] How to use the scale](/views2/1078153/page9/bg9.png)
GB
17
GB
16
How to Use the Scale
Extended Display Function
When the key is pressed while the
display is on hold, the weight is displayed
1g units for as long as the key remains
pressed.
* The extended display function cannot be used if
“Weight Lock Mode” is off
, or if the
“RECALL” or “WEIGHT GAIN” is displayed.
Keep pressing
By releasing the key simultaneously
return to the previous display.
4
After measurement, remove
the baby from the baby
basket.
If the “Hold Time” has been set, the
measurement remains on display for
the set time (see P.22). The display can
b
e reset to
g
a
t any time by
pressing the key.
s
When tare is not specified
Press the key to turn on
the power.
(Beep sound)
After flashing the display,
g
i
s
displayed.
1
3
Place the baby on the baby basket.
Once the scale stabilizes and the weight is con-
firmed, “S
TABILIZED (
"
)
” and “W
EIGHT
LOCK (
t
)” is shown. (Beep sound)
2
Press the key to set
the “Weight Lock Mode”.
“Weight Lock Mode (
t
)” is shown.
Measurement instructions
•A warning sound beeps if a baby is
placed on the basket before
g
i
s displayed.
If it happens, remove the baby from
the basket.
Release
Note
•When the load exceeds 6000 g the pointer besides the "5 g" mark appears.
Caution
•The value displayed is for information only. The scale cannot be used to certify
weight. For this reason, values cannot be output to the RS interface.
Tare weighing function
After turning on the power, the bath towel, diaper/nappy, blanket etc. is
deducted by pr
essing key. Then, the baby’s actual (i.e. net) weight
(excluding the weight of the towel, diaper, etc.) can be measured.
1
Press the key to turn on
the power.
(Beep sound)
After flashing the display,
g
is displayed.
2
Press the key to set
the “Weight Lock Mode”.
“Weight Lock Mode (
t
)” is shown.
BD815MA_GB 07.11.20, 11:36 AM16-17
Содержание
- Bd 815ma 1
- Bd815ma_gb 07 1 0 11 33 am 1 1
- Instruction manual 1
- Professional baby scale 1
- Application 2
- Baby basket attachment remova 2
- Before use 2
- Caution symbol 2
- Contents 2
- How to set up correctl 2
- How to use 2
- How to use the scal 2
- Memory function for measured value 2
- Names and functions of display panel and operation key 2
- Output data forma 2
- Part names accessorie 2
- Power suppl 2
- Safety note 2
- Specification 2
- Troubleshootin 2
- Various setting method 2
- When necessary 2
- Applications 3
- Bd815ma_gb 07 1 0 11 34 am 4 5 3
- Caution 3
- Maintenance 3
- Safety notes 3
- Warning 3
- Continued 4
- Explanation of terminology 4
- Instructions for measurement 4
- Safety notes 4
- A attachment 5
- B removal 5
- Baby basket attachment removal 5
- Caution 5
- Bd815ma_gb 07 1 0 11 35 am 10 11 6
- Confirmation of accessories 6
- Front back 6
- Part names accessories 6
- Bd815ma_gb 07 1 0 11 35 am 12 13 7
- Display panel 7
- Display panel operation keys 7
- Names and functions of display panel and operation keys 7
- Operation keys 7
- Bd815ma_gb 07 1 0 11 35 am 14 15 8
- Caution 8
- How to set up correctly 8
- Level gauge check 8
- Power supply 8
- Using batteries 8
- Using the ac adapter 8
- How to use the scale 9
- Measurement instructions 9
- Tare weighing function 9
- When tare is not specified 9
- Canceling the tare function 10
- How to use the scale continued 10
- Display weight gain 11
- G is displayed 11
- Memory cancellation 11
- Memory function 11
- Memory function for measured values 11
- Memory value recall method 11
- Place baby on the baby bas ket for a second time 11
- Press the key 11
- Press the key while 11
- Auto power off time 12
- Display hold time 12
- Flashing 12
- Off time press again 12
- Press key 12
- Press key while the screen is 12
- To complete the setting press 12
- To complete to set the auto power 12
- Various setting methods 12
- A when the display is held 13
- B when the weight gain key is pressed 13
- Bd815ma_gb 07 1 0 11 37 am 24 25 13
- C when the recall key is pressed 13
- Connection example 13
- Explanation for rs 232c compliant output 13
- Output data format 13
- Signal line name and connection method 13
- Specifications 13
- Transmission data 13
- Bd815ma_gb 07 1 0 11 37 am 26 27 14
- Check points problem 14
- Specifications 14
- Troubleshooting 14
Похожие устройства
- Fagor 2V-32TS Инструкция по эксплуатации
- Bimatek JM400 Black Инструкция по эксплуатации
- Fagor 2V-33TS Инструкция по эксплуатации
- Tanita KP-601 Инструкция по эксплуатации
- Delonghi EOB2071 Инструкция по эксплуатации
- Tanita KP-400 M Инструкция по эксплуатации
- Fagor 2VFT-211AS Инструкция по эксплуатации
- Philips HP8602/00 Инструкция по эксплуатации
- Fagor IFT-4R Инструкция по эксплуатации
- Tanita Model 1579 Инструкция по эксплуатации
- Babyliss C319E Инструкция по эксплуатации
- Fagor 3FH-4GLSTXNAT Инструкция по эксплуатации
- Tanita 1479Z Инструкция по эксплуатации
- Babyliss C338E Инструкция по эксплуатации
- Fagor 6FI-4GLSX Инструкция по эксплуатации
- Tanita 1479V Инструкция по эксплуатации
- Philips HP8618/00 Инструкция по эксплуатации
- Fagor FFK6845 Инструкция по эксплуатации
- Tanita 1475T Инструкция по эксплуатации
- Bosch DWW063461 Инструкция по эксплуатации