Truvox Multiwash II 440/PUMP [5/17] Please refer to the back of the manual for pictorial instructions

Truvox Multiwash II 240/PUMP [5/17] Please refer to the back of the manual for pictorial instructions
4 10-18
The following simple checks may be performed by the operator. If the machine is still not working, please contact your local Service Agent:
* If the fuse blows several times, the machine should be checked by an authorised Service Agent.
PLEASE REFER TO THE BACK OF THE MANUAL FOR PICTORIAL INSTRUCTIONS
Trouble
Reason
Remedy
Machine fails to start no power
Transport working lever is in bottom position
(see picture 3 on page 15)
Change to operating position (see pictorial guide)
Motor overload protector has tripped
Wait for 1 hour to allow the motor temperature
to reach room temperature. Then try again.
Transport wheels not raising off the ground
when handle lowered
Check for debris and clean machine.
Lack of voltage / electrical supply
Check fuse *, power cord, plug and socket outlet
Machine fails to pick up water from the
floor
Incorrectly fitted / damaged recovery tank
Refit or replace recovery tank
Worn brushes
Check brush pressure, if needed replace brushes.
Drum not rotating
See below
Drum not rotating
Debris around drum or base of machine
Clean drum and base of the machine.
Drum is rotating, but brushes are not
Debris around brushes
Clean or replace brushes
Machine fails to spray solution onto the
floor (MW240/Pump, MW340/Pump &
MW440/Pump only)
Faulty pump
Can you hear the pump operating? If yes, see
below.
If no:
Check pull cable is fitted correctly, see below.
Incorrectly fitted / damaged pull cable
Refit / replace pull cable - this should be on the
right hand side of the machine from the operator's
position.
No solution in solution tank
Fill solution tank
Blocked jet
Clean jet
Blocked inline filter
Clean inline filter
Blocked filter or faulty valve in solution tank
Clean / replace filter or valve
Machine only sprays when handle in
upright position
Lower handle bolts are loose
Tighten lower handle bolts
Machine fails to pour solution onto the
floor (MW240 & MW340 only)
Incorrectly fitted / damaged pull cable
Refit / replace pull cable - this should be on the
right hand side of the machine from the operator's
position.
Dirty filter in clean water tank
Empty solution tank and fill up with clean water
Blocked holes in outlet channel
Clean holes in outlet channel
Replace solution tank
Motor makes a humming noise but does
not turn
Debris around drum and base of the machine
Clean drum and base of machine

Содержание