Daikin FL25GV1NB [3/67] Caution

Daikin FLY35GV1NB [3/67] Caution
SiE-84
Service Manual
Warning
(5) The step-up capacitor supplies high-voltage electricity to the
electrical components of the outdoor unit.
Be sure to discharge the capacitor completely before conducting
repair work.
A charged capacitor can cause an electrical shock.
(6) Do not start or stop the air conditioner operation by plugging or
unplugging the power cable plug.
Plugging or unplugging the power cable plug to operate the
equipment can cause an electrical shock or fire.
Caution
(7) Do not repair the electrical components with wet hands.
Working on the equipment with wet hands can cause an electrical
shock.
(8) Do not clean the air conditioner by splashing water.
Washing the unit with water can cause an electrical shock.
(9) Be sure to provide the grounding when repairing the equipment in a
humid or wet place, to avoid electrical shocks.
(10) Be sure to turn off the power switch and unplug the power cable
when cleaning the equipment.
The internal fan rotates at a high speed, and can cause injury.
(11) Do not tilt the unit when removing it.
The water inside the unit can spill and wet the furniture and floor.
(12) Be sure to check that the refrigerating cycle section has cooled
down sufficiently before conducting repair work.
Working on the unit when the refrigerating cycle section is hot can
cause burns.