Daikin FL25GV1NB [5/67] Warning

Daikin FLY35GV1NB [5/67] Warning
SiE-84
Service Manual
Warning
(19) Be sure to use the specified cable to connect between the indoor
and outdoor units.
Make the connections securely and route the cable properly so that
there is no force pulling the cable at the connection terminals.
Improper connections can cause excessive heat generation or fire.
(20) When connecting the cable between the indoor and outdoor units,
make sure that the terminal cover does not lift off or dismount
because of the cable.
If the cover is not mounted properly, the terminal connection section
can cause an electrical shock, excessive heat generation or fire.
(21) Do not damage or modify the power cable.
Damaged or modified power cable can cause an electrical shock or
fire.
Placing heavy items on the power cable, and heating or pulling the
power cable can damage the cable.
(22) Do not mix air or gas other than the specified refrigerant (R22) in the
refrigerant system.
If air enters the refrigerating system, an excessively high pressure
results, causing equipment damage and injury.
(23) If the refrigerant gas leaks, be sure to locate the leak and repair it
before charging the refrigerant. After charging refrigerant, make
sure that there is no refrigerant leak.
If the leak cannot be located and the repair work must be stopped,
be sure to perform pump-down and close the service valve, to
prevent the refrigerant gas from leaking into the room. The
refrigerant gas itself is harmless, but it can generate toxic gases
when it contacts flames, such as fan and other heaters, stoves and
ranges.
(24) When replacing the coin battery in the remote control, be sure to
dispose of the old battery to prevent children from swallowing it.
If a child swallows the coin battery, see a doctor immediately.
SIE2-84.book Page -3 Wednesday, May 30, 2001 10:29 AM