Daikin EHSH08P50BA — инструкция по установке и эксплуатации интегрированного солнечного блока [76/84]

Daikin EHSXB16P50BB [76/84] Max heat output a10 w35 kw
Installation and operating instructions
76
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1441399_02 – 01/2021 – EN
10 x Technical data
10.2 Characteristic lines
10.2.1 Sensor characteristic lines
Temperature sensor
Measured temperature in °C
-20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120
Sensor resistance in kOhm according to standard or manufacturer's indications
t
DHW2
NTC
811.5 480.6 293.2 183.8 118.2 77.7 52.3 35.8 25.1 17.8 12.9 9.5 7.1
t
Au
(RoCon OT1),
t
DHW1
NTC
98.66 56.25 33.21 20.24 12.71 8.20 5.42 3.66 2.53 1.78 1.28 0.93 0.69 0.52 0,36
t
Au
(R1T) NTC
197,8 112,0 65,8 40.0 25.0 16.1 10.6 7.2 5.0 3.5 2.5
t
V1
, t
V, BH
, t
R2
NTC
197.80 120.00 65.84 39.91 24.95 16.04 10.58 7.14 4.77 3,19 2.36 1.74 1.33 1.07 0.84
FLS Sensor (Flow/Temperature)
FLS
(t
R1
/ V1)
V1
Measured flow in l/min
10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0
Sensor output frequency in Hz
(14 - 229 Hz)
28 54 81 108 135 162 188 215
t
R1
Measured temperature in °C
10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0
Sensor resistance in Ohm
(Pt 1000)
1039 1077 1116 1155 1194 1232 1270 1308 1347
Tab. 10-3 Sensor Table Daikin Altherma EHS(X/H)
Maximum tightening torque of sensor =10 Nm.
Max. heat output A7/W35 kW
8.4 / 10.2 11.4 / 14.6 / 16.1 8.4 / 10.2 11.4 / 14.6 / 16.1
Max. heat output A10/W35 kW
8.8 / 10.5 11.9 / 15 / 16.5 8.8 / 10.5 11.9 / 15 / 16.5
Max. cooling output A35/W18 kW
7.3 / 8.4 10.6 / 10.6 / 10.6 7.3 / 8.4 10.6 / 10.6 / 10.6
Max. cooling output A35/W7 kW
5.5 / 6.4 11.7 / 12.6 / 13.1 5.5 / 6.4 11.7 / 12.6 / 13.1
* Not all the equipment mentioned here is offered in some
countries because of the various different country-specif-
ic connection conditions.
1) T
CW
Cold water input temperature = 10 °C
T
DHW
Hot water draw-off temperature = 40 °C
T
S
Storage target temperature (charge state before
drawing off)
2) With a reference spacing of 1 m.
3) Number of individual wires in the connection cable, including protective earth.
The cross-section of the individual lines is dependent on the current load, the
length of the connection cable and the respective legal provisions.
4) Hot water storage tank only to be charged using a heat pump, without a Back-
up-Heater.
Tab. 10-2 Basic data Daikin Altherma EHS(X/H)…P50B
Type Daikin Altherma EHS(X/H)
08P50B 16P50B B08P50B B16P50B