4 Energy saving tips
Operation manual
9
EHVH04~16SU18+26CB6W
Daikin Altherma – Low temperature split
4P449982-1 – 2016.06
4 Energy saving tips
Tips about room temperature
▪ Make sure the desired room temperature is NEVER too high, but
ALWAYS according to your actual needs. Each saved degree can
save up to 6% of heating costs.
▪ Do NOT increase the desired room temperature to speed up
space heating. The space will NOT heat up faster.
▪ When your system layout contains slow heat emitters (example:
under floor heating), avoid large fluctuation of the desired room
temperature and do NOT let the room temperature drop too low. It
will take more time and energy to heat up the room again.
▪ Use a weekly schedule for your normal space heating needs. If
necessary, you can easily deviate from the schedule:
▪ For shorter periods: You can overrule the scheduled room
temperature. Example: When you have a party, or when you
are leaving for a couple of hours.
▪ For longer periods: You can use the holiday mode. Example:
When you stay at home during your holiday, or when you go
away during your holiday.
Tips about DHWtank temperature
▪ Use a weekly schedule for your normal domestic hot water needs
(only in scheduled mode).
▪ Program to heat up the DHW tank to a preset value (Storage
comfort = higher DHW tank temperature) during the night,
because then space heating demand is lower.
▪ If heating up the DHW tank once at night is not sufficient,
program to additionally heat up the DHWtank to a preset value
(Storage eco = lower DHWtank temperature) during the day.
▪ Make sure the desired DHW tank temperature is NOT too high.
Example: After installation, lower the DHWtank temperature daily
by 1°C and check if you still have enough hot water.
▪ Program to turn ON the domestic hot water pump only during
periods of the day when instant hot water is necessary. Example:
In the morning and evening.
5 Maintenance and service
5.1 Overview: Maintenance and
service
The installer has to perform a yearly maintenance. You can find the
contact/helpdesk number via the user interface.
As enduser, you have to:
▪ Keep the area around the unit clean.
▪ Keep the user interface clean with a soft damp cloth. Do NOT use
any detergents.
▪ Regularly check if the water pressure indicated on the manometer
is above 1bar.
Refrigerant
This product contains fluorinated greenhouse gases. Do NOT vent
gases into the atmosphere.
Refrigerant type: R410A
Global warming potential (GWP) value: 2087.5
NOTICE
In Europe, the greenhouse gas emissions of the total
refrigerant charge in the system (expressed as tonnes
CO
2
-equivalent) is used to determine the maintenance
intervals. Follow the applicable legislation.
Formula to calculate the greenhouse gas emissions:
GWP value of the refrigerant × Total refrigerant charge [in
kg] / 1000
Please contact your installer for more information.
5.2 To find the contact/helpdesk
number
Prerequisite: You switched the permission level to Advanced end
user.
1 Go to [6.3.2]: > Information > Error handling > Contact/
helpdesk number.
Содержание
- Operation manual p.1
- Daikin altherma low temperature split p.1
- About this document p.2
- Target audience p.2
- General safety precautions p.2
- About the system 3 p.2
- Table of contents p.2
- Format paper in the box of the indoor unit p.2
- System p.2
- Format digital files on http www daikineurope com support p.2
- Select scroll p.2
- For basic and advanced usage p.2
- Safety instructions that you must read before operating your p.2
- Energy saving tips 9 p.2
- Room temperature p.2
- End users p.2
- Request the installer to inform you about the settings that he used p.2
- Documentation set p.2
- Read the documentation carefully before operating the user p.2
- Detailed step by step instructions and background information p.2
- Quick guide for basic usage p.2
- Depending on your system layout and installer configuration not all screens in this document may be available on your user interface p.2
- Operation manual p.2
- Comfort heating eco heating p.2
- Operation 3 p.2
- Comfort heating p.2
- User reference guide p.2
- Maintenance and service 9 p.2
- Breadcrumbs help you to locate where you are in the menu structure of the user interface this document also mentions these breadcrumbs p.2
- Troubleshooting 10 p.2
- Latest revisions of the supplied documentation may be available on the regional daikin website or via your installer p.2
- Breadcrumbs p.2
- To configure your system check if he has filled in the installer settings tables if not request him to do so p.2
- Keep the documentation for future reference p.2
- Available screens p.2
- This document is part of a documentation set the complete set consists of p.2
- And manuals product information p.2
- The original documentation is written in english all other languages are translations p.2
- Interface to ensure the best possible performance p.2
- About this document 2 p.2
- Thank you for purchasing this product please p.2
- Glossary 10 p.2
- The user interface at a glance p.3
- Overview operation p.3
- Operation p.3
- G b c a p.3
- Components in a typical system layout p.3
- Buttons p.3
- About the system p.3
- Room thermostat control using the room temperature home page p.4
- Room thermostat control using the leaving water temperature home pages p.4
- Operation p.4
- Typical room temperature home pages p.4
- To temporarily overrule the room temperature schedule p.4
- To set the overrule period p.4
- To read out the actual and desired room temperature p.4
- To change the mode from scheduled to preset value p.4
- Status icons p.4
- Space heating control p.4
- Setting the space operation mode p.4
- Operation p.5
- Domestic hot water control p.5
- Schedules example p.6
- Operation p.6
- Advanced usage p.6
- About changing the user permission level p.6
- Ehvh04 16su18 26cb6w daikin altherma low temperature split 4p449982 1 2016 6 p.7
- Depending on the selected installer settings settings will be visible invisible p.7
- Operation manual p.7
- Operation p.7
- Menu structure overview user settings p.7
- Information p.7
- Space heating control p.8
- Quick wizard p.8
- Operation p.8
- Installer settings tables to be filled in by installer p.8
- Domestic hot water control a p.8
- Contact helpdesk number 6 p.8
- To find the contact helpdesk number p.9
- Overview maintenance and service p.9
- Maintenance and service p.9
- Energy saving tips p.9
- Symptom heat pump failure p.10
- Glossary p.10
- Troubleshooting p.10
- Symptom you are feeling too cold hot in your living room p.10
- Symptom the water at the tap is too cold p.10
- P449982 1 p.12
- Copyright 2016 daikin p.12
Похожие устройства
-
Daikin EVLQ08CAV3Руководство по применению для установщика -
Daikin EVLQ08CAV3Справочное руководство для монтажника -
Daikin EVLQ08CAV3Общие правила техники безопасности -
Daikin EVLQ08CAV3Инструкция по монтажу -
Daikin EVLQ05CAV3Справочное руководство для монтажника -
Daikin EVLQ05CAV3Руководство по применению для установщика -
Daikin EVLQ05CAV3Общие правила техники безопасности -
Daikin EVLQ05CAV3Инструкция по монтажу -
Daikin EHYKOMB33AA3Справочное руководство для монтажника -
Daikin EHYKOMB33AA3Руководство по применению для установщика -
Daikin EHYKOMB33AA3Руководство по эксплуатации -
Daikin EHYKOMB33AA2Руководство по применению для установщика
Узнайте, как оптимизировать температуру в помещениях и горячей воде для снижения затрат на отопление. Применяйте советы по обслуживанию для повышения эффективности.